Comnet FDC24NL Installation And Operation Manual Download Page 8

INS_FDC24NL[SFP]_REV–

12/29/11

PAGE 8

RS422 Bus With Standard Fiber Units

Multiple Units With The Same Address

FVT10D2I1C4E

Any ComNet fiber unit w/ 

an RS422 data channel

FDC24NL

Address 1

FDC24NL

Address 1

FDC24NLSFP

Address 1

FDC24NL

Address 2

FDC24NL

Address 3

LEFT

LEFT

24 Contacts IN

24 Contacts IN

24 Contacts IN

24 Contacts IN

24 Contacts IN

24 Contacts IN

24 Contacts IN

24 Contacts IN

24 Contacts IN

A

A

A

A

A

B

B

B

B

B

B

B

24 Contacts OUT

From Address 1 – Right

24 Contacts OUT

From Address 1 – Right

24 Contacts OUT

From Address 1 – Right

24 Contacts OUT

From Address 2 – Right

24 Contacts OUT

From Address 3 – Right

24 Contacts OUT

From Address 1 – Left

24 Contacts OUT

From Address 1 – Left

Contact inputs on the left side will be logic OR’ed together as both units have the same address. (e.g. closing input 1 on either unit will cause relay output 1 to close on the unit(s) with 

address 1 on the right side of the system.)
In addition, the relay outputs on both units on the left side will close when the corresponding input is closed on the unit(s) with address 1 on the right side of the system.

24 Contacts OUT

From Address 2 – Left

24 Contacts OUT

From Address 3 – Left

FVR10D2I1C4E

Any ComNet fiber unit w/ 

an RS422 data channel

FDC24NL

Address 1

FDC24NLSFP

Address 1

FDC24NL

Address 2

FDC24NL

Address 3

RIGHT

RIGHT

Cat5 Straight Patch Cable
Fiber Optic Cable

INSTALLATION AND OPERATION MANUAL 

FDC24NL[SFP] SERIES

TECH SUPPORT: 1.888.678.9427

FIGURE 12 – TYPICAL APPLICATIONS (CONT’D)

Summary of Contents for FDC24NL

Page 1: ...kets that are ordered and encoded ensuring extremely robust transmission Packets that are garbled packets out of sequence and transmission bit errors will not cause random changes of state on the cont...

Page 2: ...PE Power Supply Surface Mount 8 15 VDC 5 W Max Rack Mount From Rack NOTE Remove Electrical Connector for Rack Mount Units FIGURE 2 FDC24NL FRONT PANEL FIGURE 3 FDC24NL REAR PANEL FIGURE 1 FDC24NL RS 4...

Page 3: ...HITE STRIPE Power Supply Surface Mount 8 15 VDC 5 W Max Rack Mount From Rack NOTE Remove Electrical Connector for Rack Mount Units FIGURE 5 FDC24NLSFP FRONT PANEL FIGURE 6 FDC24NLSFP REAR PANEL FIGURE...

Page 4: ...inputs from units with the same address FIGURE 7 CONTACT CLOSURE PIN OUT PIN Wire Color Connections Polarity 1 Blue OUT 1 5 9 13 17 21 2 Orange OUT 1 5 9 13 17 21 3 Black OUT 2 6 10 14 18 22 4 Red OUT...

Page 5: ...cable Connections should be made B to A The units should always connect to a fiber device or FDC24NLSFP model using Port B PIN Wire Color Connections Polarity 1 Blue DATA IN 2 Orange DATA IN 3 Black...

Page 6: ...f that contact is currently open ON Contact Closed OFF Contact Open RED Invalid Address Selected No Fiber Connection or No Mating FDC24 Connected OFF Unit Powered Down Unit Powered Down S2 1 Relay 24...

Page 7: ...24 Contacts IN 24 Contacts IN 24 Contacts IN 24 Contacts IN 24 Contacts IN 24 Contacts IN 24 Contacts IN 24 Contacts OUT From Address 1 Right A A A A A A B B B Max 12 Uniquely Address Units B B B Max...

Page 8: ...om Address 1 Left 24 Contacts OUT From Address 1 Left Contact inputs on the left side will be logic OR ed together as both units have the same address e g closing input 1 on either unit will cause rel...

Page 9: ...and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the...

Reviews: