Port Description
UTP:
The UTP port will auto-sense connections, it can auto detect crossover or straight
cable when plugged into a connector. The Gigabit connection requires use of Cat-6 or
Cat5e 4 pairs twisted cable with correct pin alignment. If using cat-5 cable, only
100Mbps link speed is supported. The available link distance is up to 100 meters.
SC:
supports Gigabit SX or Gigabit LX for different link distance. (Please see Fiber
Transceiver label on the Module)
SX:
uses Multimode fiber cable (62.5/125um ~ 50/125um), distance < 500 meters.
LX:
uses Single mode fiber cable (8/125um ~ 9/125um), distance < 10 km.
SFP:
Hot swappable, allowing you to install different fiber transceiver while the switch is
running. The slot only supports 3.3 VDC; therefore,
please confirm the transceiver’s
power voltage is same as module
.
4.4
Installing Module in CWGE24MODMS Switch Chassis
A.
Remove the module slot cover from the chassis switch.
B.
Install the module by inserting it into the guides and sliding it in until it stops. Press it
firmly.
C.
Gently push the thumbscrews in and turn clockwise to tighten. Do not over tighten the
thumbscrews.