FIGURE a

Dimensions are for the CLFE1UTP standalone ComNet module

FIGURE B

Dimensions are for the CLFE4UTP standalone ComNet module

FIGURE C

Dimensions are for the CLFE8UTP and CLFE16UTP ComNet modules

3.73" (9.5cm)

3.6" (9.2cm)

17" (43.2cm)

1.6" (4cm)

3.3" 
(8.4cm)

1.6" (4cm)

1.75" 
(4.45cm)

3.25" 
(8.25cm)

1.6" (4cm)

1.15" (3cm)

INSTALLATION CONSIDERATIONS 

The CLFE1UTP and CLFE4UTPare supplied as Standalone modules. The 

CLFE8UTP and CLFE16UTP can be installed as Standalone modules or can 

be rack-mounted with the addition of the provided 19-Inch Rack-Mounting 

Ear Brackets. 

Summary of Contents for CLFE16UTP

Page 1: ...ngeably with other CopperLine Ethernet over UTP extenders Environmentally hardened to the requirements of NEMA TS 1 TS 2 for most out of plant applications and true plug and play design ensures ease of installation and operation LED indicators are provided for rapidly ascertaining the operating status of the device See Figures 6 8 on Page 7 for LED explanations Packaged in a rugged aluminum housin...

Page 2: ... left panel Note 4 pair mode is required for PoE Warning A ground connection is required for the surge protection to work Failure to ground properly voids the warranty and may cause damage Warning A ground connection is required for the surge protection to work Failure to ground properly voids the warranty and may cause damage 2 1 Ground Screw Ground Screw Power Supply Connection via external powe...

Page 3: ...uld be powered using the PoE source External power to the CLFE1UTP should be restricted to installations where a camera requires local power When installing the CLFE1UTP the following conditions apply which will affect its operations The CLFE1UTP is provided with the ability to operate using a local external power supply The standard accessory local power adaptor plug can be used for power supplie...

Page 4: ...CAT5 6 or UTP CAT5 6 or UTP CAT5 6 or UTP CAT5 6 or UTP CAT5 6 or UTP CAT5 6 or UTP CAT5 6 CAT5 6 CAT5 6 CAT5 6 CAT5 6 CAT5 6 Warning A ground connection is required for the surge protection to work Failure to ground properly voids the warranty and may cause damage Warning A ground connection is required for the surge protection to work Failure to ground properly voids the warranty and may cause d...

Page 5: ...16UTP PoE Switch CNGE2FE24MSPOE 328ft 100m Cat 5 CLFE4US1TPC IP Cameras IP Cameras 3 000ft 914m Cat 5 5 000ft 1524m Coax CopperLine Managed High Power Midspan NVR CLFE16IPS Switch CNGE2FE24MS Data Power Data Power CLFE1UTP CLFE1UTP CLFE1UTP CLFE1UTP PoE Camera PoE Camera CLFE16UTP Single Port CopperLine over UTP NVR PoE Switch CNGE2FE24MSPOE 3 000ft 914m Cat 5 328ft 100m Cat 5 CLFE1UTP CLFE1UTP Po...

Page 6: ...ctor should be ON to indicate proper connection between the camera and the CLFE1UTP Ethernet Switch NVR end Installation CLFE1UTP Set the S2 Master Slave dip switch to OFF for Slave mode Set the S1 and S3 dip switches to match the setting on the camera end CLFE4UTP CLFE8UTP and CLFE16UTP For each channel used set the appropriate dip switches for each channel to match the camera end Note Multichann...

Page 7: ...LED INDICATORS FIGURE 8 ETHERNET LED INDICATORS POWER RED Power is on OFF Power is off TRAFFIC Extended 10 100BaseT GREEN Connection is OK 10BaseT mode YELLOW Flashing Traffic present RED Connection is OK 100BaseT mode OFF No traffic TRAFFIC Standard Link GREEN Flashing Connection is OK with traffic YELLOW Connection is OK OFF No connection No connection ...

Page 8: ... ComNet module Figure C Dimensions are for the CLFE8UTP and CLFE16UTP ComNet modules 3 73 9 5cm 3 6 9 2cm 17 43 2cm 1 6 4cm 3 3 8 4cm 1 6 4cm 1 75 4 45cm 3 25 8 25cm 1 6 4cm 1 15 3cm Installation Considerations The CLFE1UTP and CLFE4UTPare supplied as Standalone modules The CLFE8UTP and CLFE16UTP can be installed as Standalone modules or can be rack mounted with the addition of the provided 19 Inc...

Page 9: ... such as radiators heat registers stoves or other apparatus including DVRs that produce heat Protect the power cord from being walked on or pinched particularly at the power source convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Unplug this apparatus during lightning storms or when unused for long periods of ti...