K-series OEM Board User Guide
9
Be careful that the OEM board is unable to respond to any command when set as the
differential mode, it’s better to switch to the normal mode by:
1)
Go to
Diff
– click disconnect
2)
Or send command:
Interfacemode compass compass on
Then you can send commands to OEM board.
3.5
Data recording configuration
For data recording, it provides two methods to save the raw observation data:
1) To save the raw data in the onboard memory,
For K5-series: go to
Config
-> select
Auto
Data log ->
Apply Settings
–> restart
your OEM board to activate this setting.
For K7-series OEM board, it needs to send the following command:
Set EMMC on
Saveconfig
Then go to
Config
-> select
Auto
Data log ->
Apply Settings
–> restart your
OEM board to activate this setting.
2) To save the raw data in your PC, select the folder path -> go to
Config
-> click
Local
Log
-> select
log types
->
OK