8
HYPER SEARCH
B110RB has very unique feature such as HYPER SEARCH.
HYPER SEARCH is very high speed search to sweep
500MHz bandwidth in only 12 seconds. This HYPER
SEARCH can only lock onto nearby strong signal such as
wireless tapping transmitter. The active frequencies found
during the search can be stored to the memory channel.
Maximum 50 frequencies not of current interest can be
locked out for HYPER SEARCH mode and these 50 lock
out capacity is exclusively for the mode and it is
independent of 50 lock out capacity for normal search
mode.
In HYPER SEARCH mode, one of following 4 preset banks
can be searched in about I2 seconds.
Bank 1
22.5MHz
-
470MIIz
Bank 2
470MHz
-
1013MHz
Bank 3
1013MHz
-
1570MHz
Bank 4
1570MHz
-
2059MHz
1. To activate HYPER SEARCH mode , press [2ndF]
[MANU]. And HYPEr legend is displayed on LCD.
2. To select one of above HYPER SEARCH banks, press
numeric key [1] through [4].
3. As soon as B110RB locks on strong signal, the
frequency of active signal is displayed on LCD.
4. If you would like to lock the frequency out, press [PASS]
key.
5. If you would like to memory the frequency to memory
channel, press [ENT] and refer page 13.
6. If you would like to resume the search, press UP/DOWN
key or rotate the dial in the direction you like to advance
the HYPER SEARCH.
SUGGESTIONS: Rotate squelch control in fully clockwise
which protect B110RB from frequent squelch opening at
strong signals such as FM broadcasting, TV signal and
others. If it is necessary use attenuator ([2ndF] [I]).
Sleep Timer
B110RB may be turned off after a prescribed time period.
To enable the sleep timer, press [2ndF] [5]. A clock legend
will be on the lower right of the LCD. The receiver will
automatically turned off after the default duration of 60
minutes. To de-activate the timer, press [2ndF] [5] again
and confirm the clock legend is to be disappeared from
the LCD.The sleep time duration may be programmed
between 1 to 120 minutes in one minutes increments.
Press [2ndF] [5] with the [5] key held for more than I.5
seconds. The new value may be keyed through the
numeric keypad, or UP/DOWN keys or [DIAL]. To accept
new duration, press [ENT].
Cloning data between two B110RB
It is possible to duplicate all data from one B110RB to
another B110RB. The optional adapter and interface is
required. Please refer to the manual of these adapter and
interface for the detailed information.
Remote control using a personal computer through
RSZ3.W interface
B110RB is capable of remote control using computer such
as IBM PC compatible and control software. An adapter
and external interface are optional accessories.Please refer
to the manual of the accessory package.
Specifications
Frequency coverage
100KHz - 2059MHz continuous
Receive modes
NFM, WFM, AM, ISB, USB
Sensitivity, 0.53 2.0MHz
AM 10uv
Sensitivity, 2.00 10.0MHz AM E2uv
AM 0.8V @10dB S/N
WFM 6.0uV @30dB S/N
Sensitivity,
10.00 - 400MHz
NFM 0.5uV @12dB SINAD
Sensitivity,
400- 1000MHz
NFM 0.7uV @12dB SINAD
WFM 6.0uV @30dB S/N
Sensitivity,
1000- 1300MHz
NFM 1.5uV@l2dB SINAD
Frequency increment
10Hz, 50Hz, 100Hz, 500Hz
-AM and NFM
1KHz, 5KH2, 6.25KHz, 9KHz,
10KHz, 12.5KHz, 20KHz
25KHz, 30KHz, 50KHz, 100KHz
Frequency increment
5KHz, 6.25KHz 9KHz, 10KHz,
-WFM
12.5KHz, 20KHz
Memory channels
25KHz, 30KHz, 50KHz, 100KHz
50 CH/bank x 10 banks, total
500 CH
Search banks
10 banks
Search lock out
50 channels
Scan speed
30 channels/set.
HYPER SEARCH speed
12 second for 500MHz
bandwidth
Priority channel
1 channel
Antenna connector
50 ohm unbalanced BNC
connector
Audio output
110mW - 10%THD into 8 ohm
@6V
Power requirements
4.8V from 4 x AA internal Ni-
Cad.
batteries
6.0V from 4 x AA manganese or
alkaline batteries
9.0-16.0V from external
Current drain
95mA squelched
Size
64W x 153H x 39D mm,
310 gram including Ni-Cad
B110RB (COM610) Manual m/l 28/7/00 1:38 pm Page 8