3 AP Installation
3.1 Installation pre-requisites
You have read Section 2,
Installation Preparation
.
All requirements in Section 2,
Installation Preparation
, are satisfied.
3.2 Check before installation
Prior to installing the AP, please check the following:
Connect power cord to the AP and the network. Check the status LED to make sure the AP is
operating properly. For more information about AP LEDs, see Section 1,
LEDs and ports
.
Ensure all necessary cabling have been installed.
AP4600 supports 802.at-compliant PoE. For best performance, Commsky recommends to only
use GE connection to supply power to the device.
Record the MAC address and serial number of the AP for future use. MAC address and serial
number can be found on the bottom of the AP.
3.3 Determining location for installation
Determine positions to perform the installation:
Leave as few obstacles (such as wall) as possible between APs and clients.
Install APs away from electronic devices (such as microwave ovens) that may generate radio
frequency (RF) noise.
Install APs in place where they do not hinder daily work and life.
Do not install AP in places where water is seeping, soaking, or condensing. Prevent water and
moisture from entering the AP.
3.4 Installing the AP
3.4.1 Wall-mounted
Step 1
Mark drilling locations on the wall, with a vertical separation of 65 mm to each other;
Drill two 6.5 mm holes to a depth of approximately 30 mm;
Insert two wall anchors and knock them down into the holes;
Insert two screws, leaving a gap of approximately 2 mm between the wall and the base of the
screw head.
5 CommSky Technologies, Corp.