![CommScope SYSTIMAX 360 1100GS3 Instruction Sheet Download Page 4](http://html.mh-extra.com/html/commscope/systimax-360-1100gs3/systimax-360-1100gs3_instruction-sheet_2643686004.webp)
860584440
Instruction Sheet
www.commscope.com
Page 4 of 11
Step 1
– Mount Panel to Rack
1. Mount panel to rack using the four 12-24 mounting screws provided. After securing panel to rack, snap the
Evolve cover(s) onto the front of the panel.
Note
: Verify the
SYSTIMAX
name is upright on the flat panel cover and on angled panel center cover
before snapping in place. These two covers can be installed upside down. Side covers on angled panel are
interchangeable and are not side specific.
Instructions for Installing Copper Components in Panel (See Page 7 for
Installing Fiber Components)
Step 2
– Populate Panel with Distribution Modules (For Panel Kits Only)
Note:
Distribution modules are ordered separately.
1. From the rear side of the panel, insert the front face of the module into the desired panel opening. Press
firmly until both the left and right side module snaps fully engage with the panel. When installing modules in
either of the two end positions, it is necessary to engage the outermost snap first.
Step 3
– Terminate Conductors on Rear of Panel
T568 Wiring Diagram Termination Manager
Note:
The module comes with a T568B wiring designation label installed. If T568A wiring is desired, first
remove the "B" type label and then place the "A" type label.
Do not place the "A" type label on top of the "B"
type label.
8 7 6 5
2 1 4 3
4
4
3
2
1
2
3
1
B
A
1 2 3 4 5 6 7 8
BR
BR
GR
GR
OR
OR
BL
BL
W
W
W
W
T568 Wiring Pairs
IDC Connector
Modular Jack
Front of Panel
Back of Panel
Lock tab
(2 places)
Entry
holes
Fold slots
(4 places)
Entry holes