PoE Extender Hardware Manual

This product is copyright © 2019 CommScope, LLC. All Rights Reserved.

1

Safety Notice

In support of the EC directive 2006/95.EC, this notice contains safety information important for the 

correct installation and operation of this equipment.
Note, the term SELV (Safety Extra Low Voltage) used in this addendum is defined strictly in 

accordance with EN 60950

Electrical Safety

1.

This equipment is intended for installation by trained service personnel only. 

2.

The safety requirements for Information Technology equipment is only valid if the building 

installation is in compliance with relevant national or international safety standards and in 

accordance with good engineering practice.

3.

Remove the DC supply from the supply cable at source before changing supply 

connections to this product.

4.

For safety requirements it is necessary to connect the earth point on the product to a 

reliable earth. This is a discharge path in the event of surges or lightning events on the 

supply or Ethernet cables.

5.

Unless otherwise specifically stated in the equipment installation manual, all data and 

control ports are connected to ES1/SELV/NEC Class 2 conformant circuits inside the 

enclosure. To maintain all the ports on the equipment at SELV/NEC Class 2, it is essential 

that if any connection is made to any of these ports by other equipment, the other 

equipment must maintain its relevant port at ES1/SELV/NEC Class 2.

For products that are rack mounted:

6.

For a closed or multi-unit rack assembly, the operating ambient temperature of the rack 

environment may be greater than room ambient. Ensure that the equipment environmental 

temperature does not exceed the maximum ambient temperature specified by the 

manufacturer. Ensure that air flow required for safe operation of the equipment is not 

compromised.

7.

Mounting of the equipment in the rack must not cause it to topple or other mechanical 

hazard.

8.

Ensure that the accumulative power requirements of equipment installed in the rack do not 

exceed the power supply wiring capacity of the rack. Use the equipment nameplate 

ratings to establish total requirements.

9.

Reliable earthing of rack-mounted equipment should be maintained. Particular attention 

should be given to supply connections other than direct connections to the branch circuit 

(e.g. use of power strips).

Summary of Contents for PFU-12-C-O-060-01

Page 1: ...860634349 Rev C 1 and 2 Port 60W POE Extenders and Power Extender Hardware Manual TC 96231 IP Rev C June 2019 ...

Page 2: ......

Page 3: ...n Product Procedure 7 WEEE 7 Product User Guide 7 1 Introduction 9 Why Protect Remotely Powered Circuits 10 2 Package Contents 11 3 Installation 13 SFP Configuration 15 Ethernet Cables Installation 16 Powered Fiber Cable Installation 18 DC Power Cable Installation 23 Sealing the Unit 23 Mounting the Unit 24 Solar Shield 26 4 Detailed Specifications 27 Copyright Trademarks and Commercial Disclaimer...

Page 4: ...PoE Extender Hardware Manual This product is copyright 2019 CommScope LLC All Rights Reserved ...

Page 5: ...the equipment installation manual all data and control ports are connected to ES1 SELV NEC Class 2 conformant circuits inside the enclosure To maintain all the ports on the equipment at SELV NEC Class 2 it is essential that if any connection is made to any of these ports by other equipment the other equipment must maintain its relevant port at ES1 SELV NEC Class 2 For products that are rack mounte...

Page 6: ...re are no user serviceable parts inside this equipment 11 If this equipment has a laser observe the precautions stated in the installation manual 12 Ultimate disposal of this equipment must be carried out according to relevant national laws 13 The equipment should be installed by suitably trained personnel and installation should follow good working practice ...

Page 7: ...ble des données et ports de contrôle sont raccordés à des circuits conformes à la de classe 2 SELV NEC ES1 à l intérieur de l enceinte Pour maintenir tous les ports de l équipement en classe 2 SELV NEC ES1 il est indispensable qu en cas de raccordement établi vers l un quelconque de ces ports par tout autre équipement ce dernier puisse maintenir son port correspondant en classe 2 SELV NEC ES1 Pour...

Page 8: ...ble de réparation par l utilisateur de l équipement 11 Si cet équipement comporte un dispositif laser veuillez respecter les précautions indiquées à cet égard dans le guide d installation 12 La suppression définitive de cet équipement devra être effectuée conformément aux lois nationales pertinentes 13 L équipement doit être installé par du personnel parfaitement qualifié et l installation devra ê...

Page 9: ...lationshandbuch nicht ausdrücklich anders vermerkt sind alle Datenschnittstellen und Steueranschlüsse mit ES1 SELV NEC Class 2 konformen Schaltkreisen im Inneren des Gehäuses verbunden Damit alle Ports des Geräts mit ES1 SELV NEC Class 2 konform bleiben ist es wichtig dass die Ports verbundener Geräte ebenfalls ES1 SELV NEC Class 2 entsprechen Für Geräte die in einem Rack montiert werden 6 Bei Ein...

Page 10: ...e zu wartenden Teile 11 Wenn dieses Gerät mit einem Laser ausgestattet ist beachten Sie die in der Installationsanleitung angegebenen Vorsichtsmaßnahmen 12 Die Entsorgung dieses Geräts muss nach den einschlägigen nationalen Rechtsvorschriften erfolgen 13 Das Gerät muss durch entsprechend geschultes Personal installiert werden Bei der Installation ist auf gute Arbeitspraxis zu achten ...

Page 11: ...il numerique de la class B est conforme a la norme ICES 003 du Canada Return Product Procedure If the unit is found to be defective please contact Technical Support via http www commscope com SupportCenter WEEE Instructions for recycling of items at end of life can be found at www CommScope com by searching for WEEE At time of printing this is http www commscope com About Us Corporate Responsibili...

Page 12: ...PoE Extender Hardware Manual 8 This product is copyright 2019 CommScope LLC All Rights Reserved ...

Page 13: ...ealed closure 2 Electrical power management 3 Circuit protection electronics 4 Optical to electrical Media Conversion When coupled with any standard NEC Class 2 48V DC power supply CommScope s Powered Fiber Cable system can power and communicate with PoE standard devices at far greater distances than category style copper cabling systems typically limited to 90 meters while still meeting NEC Class...

Page 14: ...th differential and common mode Secondary Protection MOV and Inductors reduce surge voltage down to 100 150 Tertiary Protection Transient voltage suppressors work at relatively low slow surges adds an extra layer of protection against voltage spikes Protects differential mode only Clamps voltage spikes to 80 100V Additional protection elements include Cross polarity protection to simplify installa...

Page 15: ...eady for cable installation with the solar shield attached Also Required Not Included 3mm and 4mm Allen wrench 1 or 2 100Base X or 1000Base X SFP transceiver s Single mode or Multi mode 25mm Torque or adjustable spanner wrench 30mm Torque or adjustable spanner wrench Phillips or Pozidriv screwdriver Silicone grease Loctite 222 Sharp knife for initial separation of the hybrid cable component parts ...

Page 16: ...PoE Extender Hardware Manual 12 This product is copyright 2019 CommScope LLC All Rights Reserved ...

Page 17: ...lide the heat shield off the retaining lugs and put to one side Remove Seal Caps and Grommets The Two port PoE Extender has 2 x M25 and 1 x M20 cable glands 60W The Single port PoE Extender has 1 x M25 and 1 x M20 cable gland Power Extenders have 3 x M20 cable glands Unscrew the caps and then remove the grommets from all of the pass through connectors Note1 Do not unscrew the pass throughs from me...

Page 18: ...PoE Extender Hardware Manual 14 This product is copyright 2019 CommScope LLC All Rights Reserved ...

Page 19: ... base This may be cut and removed if desired To configure for 100Mb s use only Using a Phillips screwdriver remove the fiber splice tray Identify the pin header and reposition the link as shown below Replace the fiber splice tray apply Locite 222 to all screws before fitting Ensure all screws are filled see below Note The delivered unit is preconfigured for 1Gb s use 26633 A TOP SFP 1 Gbit s BOTTO...

Page 20: ...to right starting with the leftmost PoE or DC power connection and ending with the hybrid cable 1 Thread the seal cap and grommet on to the cable as shown below Note If using a pre terminated Ethernet cable it may be necessary to remove the boot In some cases it may also be necessary to cut the cable and re terminate a new plug after threading the cable through the grommet 2 Before tightening the ...

Page 21: ...Manual This product is copyright 2019 CommScope LLC All Rights Reserved 17 3 Tighten the cap against the pass through The recommended torque is 2 50Nm 22 1in lbf 4 If applicable repeat steps 1 3 for the second PoE connection ...

Page 22: ...with only a knife a typical pair of wire strippers and optionally a wire cutter or snip To split the cable successfully follow this process As detailed below only use the knife to separate the parts for the first 20mm or so It is important that subsequent stripping is performed by simply pulling the conductors away from the fiber tube so that the edges are clean and smooth The dimensions of the st...

Page 23: ...ond conductor element away to the desired length 4 For the 12 AWG cable use a proper 12 AWG or 2MM diameter wire stripper For the 16AWG use a 16 AWG or 1 2mm wire diameter stripper 5 Use tape or heat shrink to prevent the cables splitting further than the required length 6 Ensure the cables are smooth to prevent water ingress issues through the grommet 7 Strip the two copper elements to an appropr...

Page 24: ... the grommet and provides a seal against water ingress 2 When threading the cable through the pass through ensure the fiber strand is uppermost when pushing the grommet in to the pass through 3 Use tape or heat shrink to prevent the cables splitting further than the required length 4 Using the Torque wrench tighten the screw cap on the pass through Tighten to torque 5Nm 3 69 ft lb Connecting the P...

Page 25: ... open Now by hand you may pull the center element jacket off revealing the aramid and optical fibers 3 Remove excess aramid as desired for termination This allows the sheath to rest on the beginning of the splice tray 4 The fibers should wrap around the splice tray several times to allow for future resplicing 5 The splice to the fiber connectors should sit in the splice island in the tray as below...

Page 26: ...mScope LLC All Rights Reserved 6 The fiber LC UPC pigtails should wrap around the splice tray once then connect to the SFPs as below Note Field installable connectors such as LightCrimp Plus can be used A clip to connect two LC simplex to one LC duplex is recommended ...

Page 27: ...nsert into the lever arm connectors Ensure the correct polarity of the connections 3 Tighten the cap against the pass through The recommended torque is 2 50Nm 22 1in lbf The output fiber cable is provided through the left pass through The fiber cable must be round and have an external diameter between 3mm and 10mm Feed the fiber through the gland and then strip and splice using the splice tray Tig...

Page 28: ... Reserved 4 Tighten the screws to torque 2 5Nm 22 1 in lb It is recommended that the center screws on each side be tightened first followed by the corner screws Mounting the Unit Wall Mount The PoE extender has 4 holes on the exterior of the device for attaching to a wall or flat surface ...

Page 29: ...roduct is copyright 2019 CommScope LLC All Rights Reserved 25 Pole Mount The four slots in the raised sections on the bottom of the device may be used for pole attachment using band clamps jubilee clips PoE pole mounted with solar shield ...

Page 30: ...ovided 1 A minimum 16AWG bonding connection from the Customer s equipment earth terminal to a reliable earth ground point 2 A minimum 16AWG bonding connection from the PoE Extender to a reliable earth ground point at or close to the earth ground point of the Customer s equipment PoE Extender Earth Point Solar Shield At the top of the Two Port PoE Extender s operating temperature range the physical...

Page 31: ...der PFU P C O 060 01 48V Power Extender PFU 48 C O 060 01 12V Power Extender PFU 12 C O 060 01 Table 4 2 Climatic Performance Item Specification Storage Temperature 40º C to 70º C Installation Temperature 5º C to 45º C Operating Temperature 40º C to 65º C 65 C assumes 45 C ambient air temperature plus 20 C sun loading Table 4 3 Physical Dimensions Item Specification Dimensions including solar shie...

Page 32: ...C Underground Ducted Table 4 4a Maximum Extender Output Power vs Powered Device Type Note 1 Single port PoE Extender only Table 4 4 Electric Transmission PSU Output Voltage Cable Gauge AWG Max Cable Length m Pout 60W Max Cable Length m Pout 45 4W Max Cable Length m Pout 30 8W Max Cable Length m Pout 30W Max Cable Length m Pout 15 4W Maximum 57V 12 650 1120 1570 1595 2630 16 255 445 620 630 1040 No...

Page 33: ... 1 2014 Compliance CE FCC CSA RCM SELV NEC Class 2 input Environmental ETSI EN 300 019 1 4 V2 3 1 2013 08 Class 4 1E EN 60068 2 52 1996 REACH SVHC RoHS2 2011 65 EU EN 60529 1992 A2 2013 IP68 NEMA 6P EN 60529 1992 A2 2013 IP64 67 Table 4 6 Communications Item Specification Optical Input Accepts all MSA compliant 100Base X and 1000Base X SFP transceivers Optical Input Singlemode ITU T G657 A2 Optica...

Page 34: ...FC S04L16 PFC Singlemode 4F I O 16AWG PFC S04O12 PFC Singlemode 4F Outdoor 12AWG PFC S04O16 PFC Singlemode 4F Outdoor 16AWG PFC S12L12 PFC Singlemode 12F I O 12AWG PFC S12L16 PFC Singlemode 12F I O 16AWG PFC S12O12 PFC Singlemode 12F Outdoor 12AWG PFC S12O16 PFC Singlemode 12F Outdoor 16AWG PFC 302L12 PFC OM3 2F I O 12AWG PFC 302L16 PFC OM3 2F I O 16AWG PFC 302O12 PFC OM3 2F Outdoor 12AWG PFC 302O...

Page 35: ...e com All trademarks identified by or are registered trademarks or trademarks respectively of CommScope Inc 2019 Commscope Inc All Rights Reserved This product is covered by one or more U S patents or their foreign equivalents For patents see www commscope com ProductPatent ProductPatent aspx For technical assistance customer service or to report any missing damaged parts visit us at http www comm...

Page 36: ...PoE Extender Hardware Manual 32 This product is copyright 2019 CommScope LLC All Rights Reserved ...

Reviews: