8.3.2
Directly to splice tray rear
1
2
1 Cut the subunits at the jacket end installed on side F2 (endcut) OR cut the subunit in the middle (midcut). The non-
used end can be re-stored in the loop storage.
2 Bring the cut subunit to the splice tray (rear) and mark the stripping point on the sheath at the level of the line in
the tray. The line indicates the stripping point, however if the stripping point is located in the transition zone which
is textured, this is acceptable.
3 Strip the subunit to this mark and clean all fibers per standard practice.
8.3.3
Via uncut fiber storage
Note:
Maximum 2 subunits can enter the uncut fiber storage.
Note:
The uncut storage basket to store uncut feeder fibers has an inner width of
60 mm (2.36 Inches)
.
The uncut fiber storage can be used with shaved subunits or with cut subunits.
8.3.3.1
Shaved subunit
1
1
1 Bring the selected subunit to the rear of the loop storage, the uncut fiber storage.
Note:
It is important that the selected subunit is routed first and that the bundle of subunits is installed back on
top of this routed subunit.
page 14 / 24