6

5.2.5    Bring shaved/stripped tube to the front side.

i

 Be careful with the pre-installed pigtails.

5.2.8    Place shaved/stripped tubes in the outer tube holder channel 
of the base tray. Insert orange rubber tube.

i

 Align the orange rubber tube with the rib indicated by the arrow. 

5.2.7    Secure the strength members. 

5.2.6    Bring strength member to the CTU at the 

back side.

 

i

 Wrong installation: make sure tube is not twisted around the 

strength member.

i

 Wrong installation: don’t bring strength member to the front side.

5.2.9    Close the latches of the multiple hinge clamp.

Front side

Back side

5.2.10   Secure the hose clamps on the inside again.

i

 Be careful with the pre-installed pigtails.

Summary of Contents for Mini-OTE 400

Page 1: ...ommScope s Mini OTE 400 terminal enables FTTH deployment in brown field and green field applications with or without coax in place The terminal is designed for a butt splice configuration in pedestal and hand hole applications The Mini OTE 400 terminal is available with 2 4 or 8 drops 1 2 Cable types The Mini OTE 400 terminal is available with 2 4 or 8 drops and two entry exit ports accommodating ...

Page 2: ...ble ties 4 Orange rubber tubing 5 Fiber picker 6 Security bolt 7 Spiral tubing Item Description 8 Foam strips 9 Gel strips 10 Plastic clip 11 7 16 hex bolts 12 Color Code label 13 Cleaning tissue 3 Part list 3 1 Kit content 1 2 3 4 5 6 7 8 9 10 13 11 12 3 2 Accessory kit for pedestal mounting ...

Page 3: ...EV APVD DWN CHK NAME SCALE MATERIAL HEAT TREAT ANGLES SURFACE TEXTURE A3 COMMSCOPE INC A A P1 P3 P5 P7 P2 P4 P8 P6 P9 P10 EK3982 PD 00 P Doultremont 12AUG2016 17 100 1 1 1 mm 1 FST SPC Inner A A Feeder cable Feeder cable P10 and P9 are the feeder cable positions Other ports are pre connectorized adapter drops with color code CONFIGURATION Connector 1 P1 Connector 2 P2 Connector 3 P3 Connector 4 P4...

Page 4: ...segments and place the spiral tube segments over the non used buffer tubes Place it over the oscillation points of the cable 4 5 Take out carefully the buffer tube that need to be connected with the pre connectorized drops i Make sure no buffer tubes get damaged Mid cut Cut the tube in the middle and strip the active and non active tube 55mm 2 17 from the jacket end Shaving Mark tube at both sides...

Page 5: ...Open latches 5 2 2 Remove dummy plugs in position P9 and P10 see feeder cable position in the configuration overview point 3 3 i Do not remove dummy plugs from ports without a factory installed drop for 2 and 4 port terminals 5 1 4 Take out the organizer with pre connectorized adapter drops 5 2 3 Remove the hose clamps on the inside Don t remove cable tie on the outside 5 2 4 Place the cable in th...

Page 6: ... with the rib indicated by the arrow 5 2 7 Secure the strength members 5 2 6 Bring strength member to the CTU at the back side i Wrong installation make sure tube is not twisted around the strength member i Wrong installation don t bring strength member to the front side 5 2 9 Close the latches of the multiple hinge clamp Front side Back side 5 2 10 Secure the hose clamps on the inside again i Be ...

Page 7: ...asket in the base tray is designed to store dark fiber or unused shaved fibers 5 3 1 Carefully make a loop of Ø 11 cm 4 33 5 3 2 Fit the loop in the basket at the back side 5 4 Store stripped shaved tubes in the basket of the base tray 5 3 Store the loop buffer tubes in the basket at the backside ...

Page 8: ... one of the 2 fibers need to make a cross on the tray see white dotted line on the picture 5 6 2 Place folded plastic clip over gel strip 5 5 Make fusion splice and store overlength in the splice tray 5 6 Insert the gel strips 5 6 3 Push gel strip covered with plastic clip through opening near gel seal cable plug from the back side loop storage to the front side 5 6 4 Pull gel strip covered with p...

Page 9: ... housing 5 6 8 Install second gel strip in the same way 6 1 Place the organizer with pre connectorized adapter drops into the terminal housing 6 Close and lock the terminal housing Front side 5 6 5 First flip gel strip end coming from the middle part to the outside i Take care gel strip is flipped to the correct side There needs to be an opening left to push through the second gel strip 5 6 6 Then...

Page 10: ... 6 2 3 Insert the locking bolt and tighten the locking bolt with a hexagonal wrench 6 2 2 Close all the latches starting with top latch towards the gel seal area Close the latches left and right side alternating 1 left 1right 1 left 6 3 3 After every gel donut re entry a break off tap should be removed from the terminal housing 6 3 4 Initial installation is not a re entry 6 3 5 Replacing a gel don...

Page 11: ...it as shown 7 2 3 Mount the mounting plates around the D bar 7 2 Installation on D Bar 7 1 1 Push the 2 bolts through the openings of the grid structure of the back plate Secure them in the inserts on the back side of the terminal housing 7 1 Installation on universal back plate 7 Pedestal Mounting 7 1 2 Installation complete ...

Page 12: ...is product is covered by one or more U S patents or their foreign equivalents For patents see www commscope com ProductPatent ProductPatent aspx 7 2 4 Secure the mounting plates around the D bar with a 7 16 wrench 7 2 6 Installation complete 7 2 5 If necessary terminal housing can be repositioned centered in the pedestal To find out more about CommScope products visit us on the web at www commscop...

Reviews: