6
6.2.2 Central strength member
6.1
Loop capacity
Make a window cut (see table). Make sure oscillation point is in the middle. Take out feeder tube and store other tubes in basket under organizer as
described in section 6.4.
It is recommended to straighten the loose tubes.
6.2
Cable retention (TENIO CTU)
6.2.1 CTU kit content
6 Cable preparation
#LT (to store)
Ø LT (mm)
Window cut (m)
4
3
1.35
<= 5
2.4
2.1
7
2.4
1.7
11
2.3
1.5
Microsheath
-
2.1
30m
m
6-10-->60mm
10-13-->70mm
13-16-->80mm
2-6-->50mm
2
1
3
2
3
4
5
1
x
6.2.3 Dual strength member
Remove one strength member and attach CTU to the side of the remaining strength member. Follow the same instructions to attach the CTU as
describe under 6.2.2 Central strength member.
6.2.4
Coated strength member
Remove coating around strength member over a length between 15mm and 20mm and follow the same instructions to attach the CTU as describe
under 6.2.2 Central strength member
Clean strength member, remove all grease.
i