background image

E

Summary of Contents for LightCrimp Plus LC

Page 1: ...the connector are a termination cover for the ferrule front of connector and a protective cap for the plunger rear of connector The duplex connector kit consists of two of each of these components and a duplex clip The duplex clip is also available separately Micro Strip Stripper 492109 2 Combination Strip Tool 1278947 1 Cable Holder Assembly 1754138 1 or 2064540 1 only used to terminate connector...

Page 2: ...e tool If the coating slides out relative to the buffer carefully push it back to the original position flush with the buffer See Figure 2 Detail C For tight buffered fiber using the strip tool or stripper strip the fiber to the first mark It is recommended stripping the fiber in three sections See Figure 2 Detail C 6 Clean the fiber with isopropyl alcohol and a lint free cloth to remove the fiber...

Page 3: ... short boot over the plunger until it butts against the connector assembly See Figure 5 Detail B 9 Remove the connector assembly from the cable holder assembly 10 For the duplex connector kit refer to Figure 5 Detail C and install the duplex clip as follows a Center the channel A connector between the duplex clip opening marked A with the recess in the connector aligned with the rib of the duplex ...

Page 4: ...E ...

Page 5: ...E ...

Page 6: ...clamp and slide the carriage forward DO NOT touch the button while sliding the carriage See Figure 3 Detail C 5 Open the fiber clamp and move the fiber slide back until it stops 6 Remove the cleaved fiber and properly dispose of the scrap fiber 1 Open the cable clamp of the cable holder assembly and position the fiber with the cleaved end facing the connector inside the clamp Move the fiber so tha...

Page 7: ...e arrow on the duplex clip b Using a biasing force push the connector into the opening until there is an audible click DO NOT force the connector onto the duplex clip c Center the channel B connector between the duplex clip opening marked B with the recess in the connector aligned with the rib of the duplex clip Make sure that the termination cover of the connector is pointing in the direction of ...

Page 8: ...CAUTION from Paragraphs 5 1 B and 5 2 B Changed 1 click to 3 clicks in Step 3 of Paragraph 5 1 C and 5 2 C Changed receptacle to holder in Step 4 of Paragraphs 5 1 A and 5 2 A Deleted Paragraph 5 1 A 6 Deleted stripper in 5 1 A 5 CAUTION Added new text to second paragraph 5 1 A 5 Added text to Paragraph 5 1 A 6 Modified Paragraph 5 1 B 5 2 B and 5 2 C 1 and 2 Added inspection pointer to Paragraphs...