1 General
MF0147A0A
Page 9
PD (mW/cm²) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B)
for general population / uncontrolled exposures which is
o
F (MHz) / 1500 for frequencies from 300MHz to 1500MHz
o
1 for frequencies from 1500MHz to 100.000MHz
RF exposure compliance may need to be addressed at the time of licensing, as
required by the responsible FCC Bureau(s), including antenna co-location
requirements of 1.1307(b)(3).
12.
Warning:
For installations which have to comply with Europe an EN50385
exposure compliance requirements, the following Power Density limits/guidelines
(mW/cm²) according to ICNIRP are valid:
o
0.2 for frequencies from 10 MHz to 400 MHz
o
F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz
o
1 for frequencies from 2 GHz to 300 GHz
13.
Caution:
Keep operating instructions within easy reach and make them available
to all users.
14.
Caution
: Corresponding local particularities and regulations must be observed.
For national deviations, please refer to the respective documents included in the
manual CD that is delivered with the unit.
15.
Caution
: Although the remote unit is internally protected against overvoltage, it is
strongly recommended to ground (earth) the antenna cables close to the
repeater’s antenna connectors for protection against atmospheric discharge.
16.
Caution
: ESD precautions must be observed! Before commencing maintenance
work, use the available grounding (earthing) system to connect ESD protection
measures.
17.
Note:
For a Class A digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his own expense.
18.
Note:
This unit complies with European standard EN60950.