Maintenance of FST-T Terminals

7.1. 

Maintenance for the FST-T terminal is limited to cleaning the hardened adapters as needed to maintain optimal  

 performance.

8. 

Drop Cable Connector Cleaning Procedure

8.1. 

Unscrew the drop cable connector dust cap from the end of the drop cable connector.

8.2. 

Examine the end of the drop cable connector and determine which is the high side and which is the low side of  

 

the connector end-face as shown in Figure 14, View 1.

Figure 15

8.3. 

Locate the cleaning tape cassette provided with the cleaning kit (Cleaning kit (FHD-ACC-CLNKIT1) sold separately.

8.4. 

Open the tape shutter by squeezing the lever on the underside of the cassette and then keep the shutter open  

 

by continuing to squeeze the lever.

8.5. 

Hold the end-face of the drop cable connector perpendicular to the cleaning tape and with the high side of the  

 

connector pointing in the direction of cleaning as shown in Figure 15, View 2.

 

Note: The drop cable connector uses angled SC type connectors. Make sure the high side of the  

 

 

connector end-face is pointing in the direction of the cleaning motion.

Figure 16

Summary of Contents for FST-T

Page 1: ...y for reliable plug n play distribution to customer premises Featuring pre connectorized hardened full size or DLX adapter drops CommScope s FST T enables FTTH deployment in brown field and green field applications with or without coax in place Primarily designed for pedestal and hand hole applications the terminal provides fast easy network connections in space constrained environments The FST T ...

Page 2: ...iber drop cable connector and the SC adapter mounted within the FST T optical port The following sections provide a description of the connector and adapter components and provide instructions for connecting or disconnecting the drop cable to from the optical ports 4 2 The basic components of the drop cable connector are shown in Figure 1 The dust cap threads onto the connector coupling nut A pair...

Page 3: ...Page 3 of 10 2019 CommScope Inc All Rights Reserved Figure 2 Figure 3 Figure 4 Figure 5 ...

Page 4: ...be immediately placed over any radiating optical connector to avoid the potential of dangerous amounts of radiation exposure This practice also prevents dirt particles from entering the connector Do not disassemble the product The user should not disassemble the product If the user thinks a repair is necessary contact the CommScope Technical Support Team Installation site condition For safe and st...

Page 5: ...6 3 4 1 2 5 6 1 2 3 4 1 2 8 11 6 5 Connecting Feeder Cable to FST T HMFOC Cable Remove the dust caps inspect and clean the feeder cable connectors Connect the feeder cable to the FST T ensuring both key ways line up Finger tighten locking threads to secure Figure 8 6 6 Installing FST T in Hand Hole Pit FST T can be fixed to the side of a hand hole pit using self tapping screw not included in kit F...

Page 6: ... T is located in pit with feeder situated below the customer ports to allow easy installer access Figure 10 6 7 Installing FST T in Pedestal FST T can be fixed to a universal backplate or stake inside a pedestal using bolt nut and washer provided in kit Figure 11 ...

Page 7: ...hts Reserved 6 8 Installing Drop Cable to FST Ensure you remove the dust caps inspect and clean the cable connectors Figure 12 Spin the drop cable inside the port until they mate correctly Figure 13 Correctly mated FST T Drop Cable Figure 14 ...

Page 8: ...d face as shown in Figure 14 View 1 Figure 15 8 3 Locate the cleaning tape cassette provided with the cleaning kit Cleaning kit FHD ACC CLNKIT1 sold separately 8 4 Open the tape shutter by squeezing the lever on the underside of the cassette and then keep the shutter open by continuing to squeeze the lever 8 5 Hold the end face of the drop cable connector perpendicular to the cleaning tape and wit...

Page 9: ...hutter 8 8 Repeat steps 8 4 through 8 6 until the connector has been cleaned three times 8 9 When the connector is clean reinstall the drop cable dust cap and tighten until finger tight 9 FST T Adapter Connector Cleaning Procedure Cleaning kit FHD ACC CLNKIT1 is required for this procedure Use the following procedure to clean the FST T optical port adapters 9 1 Using a 216B key tool unthread the o...

Page 10: ...ecifications or warranties relating to CommScope products or services CommScope is committed to the highest standards of business integrity and environmental sustainability with a number of CommScope s facilities across the globe certified in accordance with international standards including ISO 9001 TL 9000 and ISO 14001 Further information regarding CommScope s commitment can be found at www com...

Reviews: