background image

Content

  1 General

  2  Kit contents

  3 Installation

  3.1 

GENERAL

  3.2 

FIST-GCO2-BX

  3.3 

FIST-GCO2-FX

FIST-RSKG-16

I N S T A L L A T I O N   I N S T R U C T I O N

Gel seal for the round ports of FIST-GCO2-BX and FX splice 

closure

1    General product information

This kit is used to install up to 16 drop cables of max. 3 mm in one new 
unused round port of a FIST-GCO2-BX and FX.

2    Kit content

Kit content FIST-GCO2-BX6

Kit content FIST-GCO2-FX/BX8

Note: 

The lubrication oil in the kit makes it easier to

-   install gel-seal in the closure ports
-   guide cables through ports in the gel-seal.

3   Installation

3.1  

General

Thermoplastic gel seals

Number of ports

Cable range (mm)

1

11-14

2

8-11

3

6,5-8

4

4-7

8

3-5

16

0-3

FOSC-OSKG

6-15

FIST-OSKG

5-18

FIST-OSKG20

16-20

3.1.1  First cable must be installed in the position number 1. And the 
next must follow the numbering around the gel seal.

TC-910-IP
Rev A, Feb 2017
www.commscope.com

Summary of Contents for FIST-RSKG-16

Page 1: ...CO2 BX and FX 2 Kit content Kit content FIST GCO2 BX6 Kit content FIST GCO2 FX BX8 Note The lubrication oil in the kit makes it easier to install gel seal in the closure ports guide cables through ports in the gel seal 3 Installation 3 1 General Thermoplastic gel seals Number of ports Cable range mm 1 11 14 2 8 11 3 6 5 8 4 4 7 8 3 5 16 0 3 FOSC OSKG 6 15 FIST OSKG 5 18 FIST OSKG20 16 20 3 1 1 Fir...

Page 2: ...order to have a good cable management make sure all cables have the same length 3 2 5 Mark the drop cable just below the metal bracket and pull a bit further Remove the outer cable jacket 2 2m and install mini termination unit as shown Note maximum cable diameter to be used in mini termination unit is 2 1 mm 3 2 4 Feed the drop cable through the port Respect cable lengths 3 2 1 Before installing t...

Page 3: ...ramid strength member under tension and close the hinging part 4 Apply some tension to the aramid strength member without pulling at the cable Cut away the remaining strands 1 2 3 4 3 2 7 Pull back the cable and install the mini termination unit in the holder Secure with the O ring 3 2 8 Tighten the trigger till it buts up with the flange locking system 3 2 9 Optional apply some foam to the cable ...

Page 4: ... and insert the new cable Proceed as from 3 4 3 3 2 Make sure that the bracket is in the center of the port Always start with ports 3 and 8 Proceed starting again from 3 4 til 3 8 3 3 1 Install the bracket at the corresponding part Fix with screw 3 3 FIST GCO2 FX BX8 ...

Page 5: ...cables to be secured outside the closure The marks 4 and 7 must be nearest to the corresponding ports C Optional FIST GCO2 BX8 FIST GCO2 BX8 cable securing frame C1 A cable securing system can be mounted on to the base of the FIST GCO2 BX8 with 4 screws This allows cables to be secured outside the closure C2 Apply some foam to the cable s and secure with tie wrap s to the frame ...

Page 6: ...6 ...

Page 7: ...7 ...

Page 8: ...t any specifications or warranties relating to CommScope products or services This product is covered by one ore more U S patents or their foreign equivalents For patents see www commscope com ProductPatent ProductPatent aspx To find out more about CommScope products visit us on the web at www commscope com For technical assistance customer service or to report any missing damaged parts visit us a...