background image

408-8875 

Rev E

 

of 2 

Figure 2 

1.3.

 

Installation 

1.  Slide the O-ring over the threaded portion of the receptacle. See Figure 2. 

2.  Insert the threaded portion of the receptacle through the front of the panel or faceplate. Orient the 

receptacle in the cutout so that the white arrow indicator on the front of the receptacle is facing up. 
See Figure 2. 

3.  From the back of the panel or faceplate, thread the nut onto the threaded portion of the receptacle. 

See Figure 2. Tighten the nut to a torque of 2.26 Nm [20 in.-lb]. 

4.  Refer to Figure 3, and insert the jack or coupler into the receptacle as follows: 

a.  From the back of the receptacle, align the fixed latch of the jack or coupler with the white arrow 

indicator of the receptacle.  

b.  Tilt the back of the jack or coupler up at a slight angle, and slide it into the opening of the 

receptacle. Hook the fixed latch into the slot inside the receptacle.  

c.  Rotate the back of the jack or coupler down so that the movable latch deflects and locks into the 

receptacle. 

Figure 3 

2.

 

REVISION SUMMARY 

Revisions to this instruction sheet include: 

 

Rebranded to 

CommScope

®

 

Nut 

O-Ring 

Back of 

Faceplate (Ref) 

White Arrow Indicator 

of Receptacle 

Recommended Panel or Faceplate Cutout 

Installing Receptacle 

Note: Not to Scale 

25.65 mm 

[1.010 in.] 

 28.45 mm 

 [1.120 in.] 

White Arrow Indicator 

of Receptacle 

Front of Receptacle 

Movable Latch 

Jack (Ref) 

Slot Inside of 

Receptacle 

Fixed Latch 

Opening of 

Receptacle 

Fixed Latch 

Movable Latch 

Rotate 

Jack 