background image

(Continued from page 11)

9. Items 6 & 7 are only used for adjusting the downtilt. 

    For 0 deg tilt, they are not used and could be stowed on the mounting bracket (Item 10)

.

BSAMNT-SBS-2-3 KIT

MINIMUM TILT VIEW

ITEMS 6 & 7 NOT SHOWN

MINIMUM TILT VIEW

ITEMS 6 & 7 ARE STORED ON THE MOUNT ASSY

Place edge of inclinometer against edge

of mounting rail ensure antenna is at 0°.

7

10

6

(continued on page 13)

Page 12 of 13

www.commscope.com

© 2019 CommScope, Inc. All rights reserved.

Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information.

All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. 639848 E (08/19)

639848

Summary of Contents for BSAMNT-SBS-2-2

Page 1: ...7mm wide antennas with 3 mount points side by side Please visit the product page of this mounting kit on the CommScope webpage for a list of antennas which are supported by this bracket PRE INSTALLATION INSTRUCTIONS continued on page 2 GENERAL INFORMATION Mounting systems for cylindrical pipe installations 60 115 mm 2 4 4 5 pipe diameter for heavy duty applications 350 mm 13 8 WIDE ANTENNAS 457 mm...

Page 2: ...KAGE BRACKET 12 10 MOUNTING BRACKET BACK GALV 3 11 SCR HCS HEX M10X40 STL GALV 36 12 WSHR LK SPLT M10 STL GALV 36 13 NUT HEX M10 STL GALV 72 14 WSHR FLT M10 10 5X20X2 STL GALV 36 15 PIPE MOUNTS MIDDLE 1 Page 2 of 13 www commscope com 2019 CommScope Inc All rights reserved Visit our website at www commscope com or contact your local CommScope representative or BusinessPartner for more information A...

Page 3: ...s lock washers flat washers and nuts Items 11 12 14 13 Hand tighten these nuts Item 13 See sequence 2 3 Repeat the sequences 1 2 to install another antenna 4 Fully tighten all nuts After top bracket plate is installed repeat step 2 for the bottom bracket plate When brackets properly installed the gap between antenna and caps should be 42 mm 1 65 as shown Fully tighten the linkage brackets Hand tig...

Page 4: ...tem 13 See sequence 2 3 Repeat the sequences 1 2 to install another antenna 4 Keep antenna with plate Item 8 parallel Then fully tighten all nuts After top bracket plate is installed repeat step 2 for the bottom bracket plate and middle bracket plate When brackets properly installed the gap between antenna and caps should be 44 mm 1 7 as shown Hand tighten the linkage bracket Hand tighten the link...

Page 5: ...n 2 places The top arm with welding Item 6 won t be installed if the antenna is 0 deg downtilt See 0 degree tilt view as illustrated on sheet 10 Mount Assembly Top 0 DEGREE TILT VIEW BSAMNT SBS 2 3 KIT Mount Assembly Middle 15 8 6 8 2 5 5 4 3 3 4 4 3 3 4 5 5 2 639848 Page 5 of 13 www commscope com 2019 CommScope Inc All rights reserved Visit our website at www commscope com or contact your local C...

Page 6: ... carriage bolt Item 2 flat washer lock washer and M16 nut Items 3 4 5 Hand tighten them on 2 places BSAMNT SBS 2 3 KIT Mount Assembly Bottom 8 4 5 2 3 4 5 3 4 5 BOLT DIAMETER TORQUE M16 96 N m 71 ft lbs 639848 Page 6 of 13 www commscope com 2019 CommScope Inc All rights reserved Visit our website at www commscope com or contact your local CommScope representative or BusinessPartner for more inform...

Page 7: ...rriage bolt Item 2 and flat washer lock washer M16 nut Items 3 4 5 4 Hand tighten M16 nuts Item 5 Make sure the distance L The distance between mounting plates on the antenna Make sure the distance D The distance between mounting plates on the antenna Note The tether can be a rope wire rope chain or similar material The tether should be short enough to prevent the antenna from tilting beyond its m...

Page 8: ...4 5 6 7 BOLT DIAMETER TORQUE M16 96 N m 71 ft lbs 639848 Page 8 of 13 www commscope com 2019 CommScope Inc All rights reserved Visit our website at www commscope com or contact your local CommScope representative or BusinessPartner for more information All trademarks identified by or are registered trademarks or trademarks respectively of CommScope Inc 639848 E 08 19 ...

Page 9: ... m 71 ft lbs Page 9 of 13 www commscope com 2019 CommScope Inc All rights reserved Visit our website at www commscope com or contact your local CommScope representative or BusinessPartner for more information All trademarks identified by or are registered trademarks or trademarks respectively of CommScope Inc 639848 E 08 19 639848 ...

Page 10: ...m 71 ft lbs Page 10 of 13 www commscope com 2019 CommScope Inc All rights reserved Visit our website at www commscope com or contact your local CommScope representative or BusinessPartner for more information All trademarks identified by or are registered trademarks or trademarks respectively of CommScope Inc 639848 E 08 19 639848 ...

Page 11: ... 96 N m 71 ft lbs Page 11 of 13 www commscope com 2019 CommScope Inc All rights reserved Visit our website at www commscope com or contact your local CommScope representative or BusinessPartner for more information All trademarks identified by or are registered trademarks or trademarks respectively of CommScope Inc 639848 E 08 19 639848 ...

Page 12: ...STORED ON THE MOUNT ASSY Place edge of inclinometer against edge of mounting rail ensure antenna is at 0 7 10 6 continued on page 13 Page 12 of 13 www commscope com 2019 CommScope Inc All rights reserved Visit our website at www commscope com or contact your local CommScope representative or BusinessPartner for more information All trademarks identified by or are registered trademarks or trademark...

Page 13: ...transmit power be turned off when the field installation is performed Follow all applicable safety precautions as shown on this page Remote Electrical Tilt Connection The AISG connector fitted to the antenna is designed to accept any AISG compliant cable assembly commscope recommends hand tightening AISG mating connector only Applied torque to the connector shall not exceed 1 5N m RF Cable Connect...

Reviews: