ADCP-90-606 • Rev C • May 2020
Page 37
© 2020
CommScope
. All Rights Reserved.
Figure 47. Pressing Release Tabs
8. Locate #4-40 bonding screws that are sent separately with the ship-along parts (six screws
for 3RU, twelve for 4RU).
9. Install the #4-40 screws on either side of the panel shell at the points indicated in
. Tighten to 6 inch-lbs (0.7 Nm) of torque
10. Repeat steps 1 through 6 for each RapidReel cable spool tray that requires mounting in the
panel shell.
Figure 48. Install #4-40 Bonding Screws
6.4
Unwinding Microcable from RapidReel Cable Spool Trays
After the external spool has been paid out and the RapidReel cable spool tray installed in the
panel shell, the remaining microcable on the RapidReel cable spool tray can be unwound. Use
the following procedure to unwind the microcables from the internal spool:
1. Open the panel front cover to provide clearance for the spool to rotate.
2. Do the following for each of the three or six RapidReel cable spool trays if not already in
the payout position:
25788-A
SEE DETAIL A
DETAIL A
RELEASE
TABS
*6-32
SCREW
24071-B
SEE DETAIL A
DETAIL A
*INSTALL SCREWS ON BOTH
SIDES OF PANEL. TIGHTEN TO