CommRadio CR-1a User Manual – Rev 1 Edition: 15 July 2015
7
5.
Frequency Stepping [STEP]
The CR-1a Steps sequentially through frequencies and does not stop on a
channel or frequency if a signal is present (not a scanner).
•
Push
[STEP]
to start stepping in increments corresponding with the
cursor position.
•
Cursor range: 100 kHz to 10 Hz.
•
Steps within the selected band boundaries.
•
To stop stepping: Push
[STEP]
or rotate
[T]
.
•
To reverse stepping direction (while stepping):
[<] or [>]
6.
Memory [MEM]: Save-Recall-Step
•
Save a frequency example:
Save 18.150 MHz to Memory page 2, slot (memory location) 4.
Push
[MEM].
There are 8 pages of memory. Each page has 8
slots. Use
[<]
or
[>]
to index through pages. Select page 2. Note the tuned
frequency is shown in upper right of display.
Push
[MEM]
to enter the selected page. Use
[<]
or
[>]
to
index through memory slots.
Hold [
MEM]
2 seconds.
Exit options (return to Main display):
•
Rotate
[T]
1 increment CW or CCW. The frequency will not change until next increment.
•
Timeout (see Menu Timeout selections on page 11).
•
Recall a frequency example:
Recall 18.150 MHz from Memory page 2, slot 4.
Push
[MEM].
There are 8 pages of memory. Use
[<]
or
[>]
to index through
pages. Select page 2. Note the tuned frequency is shown in upper right of
display.
Push
[MEM]
to enter the selected page. Use
[<]
or
[>]
to
index through memory slots. Select slot 4.
Push [
MEM]
(momentarily).
Exit options if frequency not selected:
•
Rotate
[T]
1 increment CW or CCW.