Commercial Electric PBC-350 Instruction Manual Download Page 6

5

GENERAL SAFETY INSTRUCTIONS (cont.)

c) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the pump.

Keep cord away from heat, oil, sharp edges or moving parts. 

Damaged or entangled cords

increase the risk of electric shock.

e) When operating a pump outdoors, use an extension cord suitable for outdoor use. 

Use of a

cord suitable for outdoor use reduces the risk of electric shock.

3) PERSONAL SAFETY
a) Stay alert, watch what you are doing and use common sense when operating a pump. Do not

use a pump while you are tired or under the influence of drugs, alcohol or medication. 

A

moment of inattention while operating pumps may result in serious personal injury.

b) Avoid accidental starting. Ensure the switch is in the off position before plugging in. 

Carrying

pumps with your finger on the switch or plugging in pumps that have the switch on invites accidents.

c) Remove any adjusting key or wrench before turning the pump on.

A wrench or a key left

attached to a rotating part of the pump may result in personal injury.

d) Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves

away from moving parts. 

Loose clothes, jewellery or long hair can be caught in moving parts.

4) PUMP USE AND CARE
a) Disconnect the plug from the power source before making any adjustments, changing

accessories, or storing pumps. 

Such preventive safety measures reduce the risk of starting the

pump accidentally.

b) Maintain pumps. Check for misalignment or binding of moving parts, breakage of parts and

any other condition that may affect the pumps operation. If damaged, have the pump

repaired before use. 

Many accidents are caused by poorly maintained pumps

.

c) Use the pump, accessories and tool bits etc., in accordance with these instructions and in

the manner intended for the particular type of pump, taking into account the working

conditions and the work to be performed.

Use of the pump for operations different from intended

could result in a hazardous situation.

5) SERVICE
a) Have your pump serviced by a qualified repair person using only identical replacement parts.

This will ensure that the safety of the pump is maintained.

b) If the supply cord is damaged, 

it must be replaced by the manufacturer, its service agent or

similarly qualified persons in order to avoid a hazard.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PBC-350

Page 1: ...PBC 350 INSTRUCTION MANUAL 0212 WARNING Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all...

Page 2: ...s product has been designed for numerous water transfer applications These include draining flooded laundries bathrooms basements or garages emptying rainwater tanks pools and spas and transferring wa...

Page 3: ...e 2 Pump Housing 3 Outlet pipe lower section 4 Outlet pipe upper section elbow 5 Tap connector assembly 6 Tap adaptor 7 Suction Base 8 Float Switch 9 Float Switch Adjustor 10 Float Switch Cable 11 Cor...

Page 4: ...ICAL SAFETY GENERAL SAFETY INSTRUCTIONS ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS PACK CONTENTS PREPARATION SET UP INSTALLATION OPERATION HINTS WHEN USING THE PUMP MAINTENANCE SPARE PARTS TROUBLESHOOTI...

Page 5: ...rts automatically after it has cooled down Using an extension lead Always use an approved extension lead suitable for the power input of this product Before use inspect the extension lead for signs of...

Page 6: ...Do not wear loose clothing or jewellery Keep your hair clothing and gloves away from moving parts Loose clothes jewellery or long hair can be caught in moving parts 4 PUMP USE AND CARE a Disconnect t...

Page 7: ...water pump together with associated pipework operate under pressure Do not disconnect water pump or pipework until internal pressure has been released Failure to do this could result in personal inju...

Page 8: ...ump has not been damaged Unpack the contents Note Use the handle 1 when lifting or moving the pump Never hang the pump by the power cable Fig 1 The pump can be used in either permanent applications or...

Page 9: ...upper section 4 Fig 6 Note Make sure the Tap adaptor 6 is firmly tightened so that the rubber seal is compressed between the Tap adaptor 6 and the Outlet pipe upper section 4 This ensures no water or...

Page 10: ...rizontal start up level or above the handle 1 the pump will turn on and operate water depth of 500mm Fig 11 ATTENTION The pump runs as soon as the float switch 8 reaches the start up level 2 When the...

Page 11: ...re the pump is disconnected from electric power supply before performing maintenance procedures Cleaning the Pump Housing Use a moist cloth to wipe down the pump housing 2 Allow to dry thoroughly befo...

Page 12: ...order to remove all the air or lift and tilt the pump slightly while the pump is running Discharge hose tube not included is kinked or damaged Un kink the discharge hose tube Or replace matter and deb...

Page 13: ...e the pump is connected into 230 240V power supply The fluid contains particles thicker than 0 5mm Ensure the pump is not being used with particles thicker than 0 5mm The motor is faulty or damaged Co...

Page 14: ...cled material decreases pollution in the environment Please recycle packaging where facilities exist Check with your local council authority for recycling advice V Volts Hz Hertz Alternating current W...

Page 15: ...YOU MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR CUSTOMER SERVICE HELPLINE TO ENSURE...

Reviews: