4
Run your low voltage cables and the included 14/2 with ground UL
approved electrical building wire from the top opening in the wall
through the bottom opening in the wall.
TIP:
Straighten out the
cable from the top plate BEFORE running the cable through the wall.
You will need to fish the cables from the top opening to the bottom
opening. (For exterior walls as you may need to use the Commercial
Electricft Mini Cable Snake) BEFORE installing the top power plate
into the top template opening, make sure to pull your low voltage
cables through the low voltage cable opening at the back of the
plate.
RUN CABLES THROUGH WALL
□
□
5
Installation
6
W
all Opening
Now that you have pulled the top power outlet plate’s electrical building wire
through the bottom hole on the wall, bend the wire straight. Break the tab on
the back of the white old work box (D) and push the stripped end of the
wire through the opening. Insert the stripped end of the wires into the push-in
connectors. First, insert the stripped black wire into the open side of the push-in
connector with the black wire – be sure to push the stripped black wire
completely into the connector. Insert the stripped white wire into the open
side of the push-in connector with the white wire. Next, insert the bare copper
ground wire into the open side of the push-in connector with the green ground
wire. Push all of the wires and the push-in connectors into the white old work
box. Screw the white old work box to the back of the bottom plate (B).
Do not plug in the supplied 6ft. extension cord until the installation of the
wallplates are completed.
INSTALLING THE TOP PLATE
Installation of Electrical Connectors
Installation Guide
Flat Panel TV Cable Organizer Kit
Item #1001863164
Model #5623-WH
Electrical Wir
e
Connect Here
A
B
D
After inserting your low voltage cables and the electrical building wire
through the opening for the top plate (A), insert the top plate (A) into the
wall by inserting the electrical work box into the wall first. Slowly slide
the top power plate (A) into the opening. Swing the top of the plate into
position until the entire plate is flush against the wall. Using a
Phillips
head screwdriver
, tighten the screws with wings. These wings fasten
tightly against the back of the drywall.
Do not
overtighten screws.
A
RoHS Compliant
This product is patent protected by
U.S. Patent number:
7390964B2, 7399920B2,
D553475S, D554475S and D568719S
ETL LISTED
CONFORMS TO
UL STD. 498
CERTIFIED TO
CAN/CSA STD. C22.2#42.1:200-1
3026001