10
11
Completing a Battery
Voltage Measurement
20m
2m
A
10A
200m
2M
200k
9V
1.5V
10A
10A
MISUSE CAN RESULT FUSE BLOWN
Press Data Hold Button to hold the
measurement on display
Insert the RED test lead to V
Ω
socket
and BLACK test lead to COM socket ,
and rotate function knob switch to
1.5V or 9V battery test setting.
Connect BLACK test lead to negative and
RED test lead to positive terminal of battery.
Insert the RED test lead to V
Ω
socket “C” and
BLACK test lead to COM socket , and
rotate function knob switch “B” to the highest
V AC ( ) setting (600V).
NOTE: Do not attempt to
measure over 600V or 200mA
Measure voltage and rotate function knob
switch to lower range V AC ( ) settings to
receive highest resolution measurements (600V).
AC Voltage Measurement (
≤
600V)
Insert the RED test lead to V
Ω
socket and
BLACK test lead to COM socket , and rotate
function knob switch to the highest V DC
( ) setting (600V).
Measure voltage and rotate function knob switch
to lower range V DC ( ) settings to receive
highest resolution measurements (600V).
DC Voltage Measurement (
≤
600V)
Press again to release the display and
return to measurement.
F
C
D
D
C
D
B
B
Red Test Lead
Black Test Lead
B
B
Red Test Lead
Black Test Lead
1-888-526-6193
Summary of Contents for 1001 418 355
Page 1: ...1 888 526 6193 1 888 526 6193...
Page 5: ...8 9 CORRECT INCORRECT 1 888 526 6193...
Page 10: ...18 19 1 888 526 6193...