background image

commend.com

OD10 TD CM

TE 

|

 1

Security and Communication

The design and/or specifications of products may be subject to change for improvement without prior notice. Errors excepted.

OD10 TD CM 

DATA SHEET  V1.3/0522

Extent of supply

 

– Intercom station

 

– Cleaning cloth

 

– I/O plug

 

– Cat. 6 patch cable (0.3 m/12 in)

 

– TX 08 screwdriver

 

– Claiming code

 

– Short reference

Technical specifications

Technical data 

IP rating:

IP65 (acc. to EN 60529)

Mechanical impact resistance:

IK07 (acc. to EN 62262)

Salt spray test:

672 h (acc. to IEC 60068-2-11/EN 9227)

Front panel:

hardened glass, AG85, 3 mm (0.12 in)

Microphone:

two digital MEMS microphones

Loudspeaker:

special membrane type for optimal sound quality, 2 x 8 Ω

Amplifier:

integrated class-D amplifier with 10 W

Sound pressure level:

max. 99 dB

Display:

10.1˝ touch display (IPS-TFT)

resolution: 800 x 1280 pixels

luminance: typ. 1000 cd/m

2

Inputs:

3 inputs for floating contacts 

(switches, push buttons, relay outputs etc.) 

1)

Outputs:

2 relay outputs

max. switching voltage: 60 VDC, 30 VAC

peak

 

2

max. switching current (per output): 2 A

max. switching power (per output):   

60 W (DC), 37.5 (VA AC)

electrical expected life:  

min. 5 x 10

5

 (30 VDC/2 A), min. 2 x 10

5

 (30 VDC/1 A)

Audio bandwidth:

up to 20 kHz

Audio codecs: 

Opus, G.722, G.711 a-law and G.711 u-law

Video features:

codecs: H.264 (SIP video and ONVIF), 

MJPEG (HTTP video and ONVIF) and RTSP

ONVIF specification: ONVIF Profile S

IT security:

SIP over TLS, SRTP, IEEE 802.1X, MJPEG via HTTPS, 

HTTPS for accessing the web interface and interfaces

Protocols:

IPv4, IPv6, TLS, TCP, UDP, HTTP (RFC 2617, RFC 3310), 

HTTPS (RFC 2818), RTP (RFC 3550), 802.1x EAP-TLS 

(RFC 5216), 802.1x EAP-MD5 (RFC 2284), RTCP, RTSP 

(RFC 2326), DHCP, DHCPv6, SDP (RFC 2327, RFC 4566), 

SSDP, SIP (RFC 3261), SIP over TLS, SNMPv2c, STUN 

(classicstun), SMTP, DTMF Decoding (RFC 2976, 

 

RFC 2833, SIP Info), ICMPv6 (Router discovery), 

MQTT (ISO/IEC 20922)

Operating temperature range:

–25 °C to +55 °C (–13 °F to +131 °F)

Storage temperature range:

–25 °C to +65 °C (–13 °F to +149 °F)

Relative humidity:

up to 95%, not condensing

Connection:

RJ45 jack for Ethernet and PoE (10/100 Mbit/s)

2 x 2.0 USB (Type A) for external devices 

3)

Power supply 

4)

:

PoE+: IEEE 802.3at/Class 4

Cabling:

min. Cat. 5, shielded 

5)

Approvals and compliances:

EN 61000-6-2, EN 61000-6-3, EN 55032 Class B,  

EN 55024, EN 60529 IP65, EN 62262 IK07, 

IEC 60068-2-11, EN 62368-1

Wall mounting:

drywall/panel mount kit OD10 FB

flush mount box OD10 FBS (requires OD10 FB)

surface mount kit OD10 SH

Dimensions (H x W x D):

with flush mount kit: 

326 x 174 x 20 mm (12.83 x 6.85 x 0.79 in)

with surface mount kit: 

326 x 174 x 43 mm (12.83 x 6.85 x 1.69 in)

Weight incl. packaging:

approx. 3,000 g (6.61 lbs)

Technical data camera

Image sensor:

1/3˝ RGB CMOS

Lens: 

F2.4, fixed aperture,

150° diagonal angle,

145° horizontal angle,

123° vertical angle

Minimum illumination:

B/W: 1 lux, colour: 1.5 lux

Resolution (W x H):

1280 x 960 pixels

Frame rate: 

up to 30 fps

Video streaming:

up to 6 HTTP video streams simultaneously 

Access

The device can be accessed through IPv4 (DHCP), IPv6 (link-local) and zero-
conf. For information on accessing the web interface, see the product manual.

Optional accessories:

AFIL-USB (induction loop kit)

EB1E1A (USB I/O module)

EB3E2A-AUD (expansion module)

IP Secure Connector (safety switch box)

PA 25W POE-DC (power injector)

RJ45-MONT (Ethernet socket)

1)

 For the switching positing “ON”, the switch resistance has to be less than 1 kΩ.

2)

 The relay output may only be connected to an ES1 or a SELV circuit! An ES1 circuit as per IEC/EN/

UL 62368-1 or a SELV circuit as per IEC/EN 60950-1 must be separated safely from a dangerous 

electrical circuit (e.g. 230 V or 110 V mains power), e.g. by means of double insulation. The ES1 or 

SELV circuit must not exceed 60 VDC or 42.4 VAC

peak

 (30 VAC

eff

)!

3)

 The USB connections are only intended for use with Commend devices. Do not use the USB jacks 

e.g. to charge mobile phones.

If a USB device should be installed separately using a USB extension cable, the USB cable length 

must not exceed 3 m. In addition to that, it is recommended to attach a ferrite to a USB cable with 

a length of 1 m or more.

4)

 For power supply, a PoE switch or PoE injector is required (not included in extent of supply), e.g. 

IP  Secure  Connector.

5)

 The maximum line length of Cat. cabling in a LAN is 100 m (328 ft) – e.g. from switch to Intercom 

station.

System requirements

Server

 

– VirtuoSIS (min. version 5.0) or

 

– S3/S6 (min. version 7.1) or

 

– Compatible SIP server or

 

– Serverless operation

Configuration software

 

– Set-UP min. version 1.5.3

Summary of Contents for OD10 TD CM

Page 1: ...luminium Thanks to their timeless look they are ideally suited for use as multi functional Intercom stations with advanced security mode for modern office buildings Ready for Symphony Cloud Services T...

Page 2: ...g ensure a long prod uct life under outdoor conditions Up to 20 kHz speech quality and OpenDuplex for natural hands free communication with high volume capacity The Intercom stations are optimally pro...

Page 3: ...ation e g to access the connected Ethernet cable the IP Secure Connector interrupts the con nection to Intercom station and LAN This ensures that it is neither possible to access the network nor to op...

Page 4: ...ion security Mandatory change of the default password during the first login Minimum password length 12 characters Detection of brute force attacks at login Documentation and securing of network ports...

Page 5: ...4 Cabling min Cat 5 shielded 5 Approvals and compliances EN 61000 6 2 EN 61000 6 3 EN 55032 Class B EN 55024 EN 60529 IP65 EN 62262 IK07 IEC 60068 2 11 EN 62368 1 Wall mounting drywall panel mount ki...

Page 6: ...not use the Intercom station when the glass is damaged Disconnect the Ethernet cable for any maintenance of the device Do not make any modifications to the Intercom station All connected circuits sha...

Page 7: ...r mounting holes 2 OD10 TD CM 18 0 71 2 5 mm 0 2 in Surface mount kit OD10 SH Measuring units in mm in not to scale 50 1 97 175 6 89 328 12 91 Flush mount box OD10 FBS Measuring units in mm in not to...

Page 8: ...he provided strain relief using the cable ties included in extent of supply of the OD10 TD CM Attach the blind cover included in extent of supply to the bottom side of the Intercom station using a scr...

Page 9: ...bottom or rear Screw the mounting box to the wall or to the 2 fold flush mounted box with the arrow pointing upwards Guide the required cables through this entry Ethernet I O and USB cable if needed r...

Reviews: