background image

Touch screen station TS 8210V I

20

1.1/0418

          <X>90</X>

          <Y>0</Y>

        </Location>

        <Size>

          <Width>10</Width>

          <Height>10</Height>

        </Size>

</Rect>

<Maintenance Touch Points>

<Rect>: The touch points are defined as rectangles.

<Location>: Shows the location of the touch point.

<X>, <Y>: The values entered referred to a percentage of the screen size.

<Size>: Indicates the size of the point.

<Width>, <Height>: The entered figures refer proportional to the size of the screen.

5.1.6

IP Station Config

Configuration ET 908H

Follow the instructions below to configure the module ET 908H in IP Station Config. Optionally,
the station can be configured with active (

) or inactive (

) DHCP:

 

Configuration – DHCP active

1. Open IP Station Config.
2. In the drop-down list 

BootMode

, select “

Boot as IoIP

”.

3. Activate the checkbox 

DHCP

.

4. In the field 

Mac

, the MAC address of the IP subscriber is indicated (cannot be configured).

5. In the field 

Card-IP

, enter the IP address of the IP subscriber card that shall be allocated to

this IP subscriber.

6. In the field

 Port

, the standard destination port number can be entered (by default,

“16400”). The port numbers must only be changed for special configurations with NAT.

7. With activated DHCP, activate the checkbox 

DYN

 in order to activate the dynamic registra-

tion via the MAC address.

8. Click on 

Write settings

.

 

Configuration – DHCP inactive

ATTENTION: Deactivate the touch points

After the configuration, it is recommended to remove the maintenance touch points. To
deactivate the touch points comment out the tags <Rect> (e.g. <!--<Rect> ... </Rect>-->).

A deleted or incorrect touch point configuration can be edited in a remote desktop session
or via file access.

Write down the computer name and the IP address to enable the connection by remote
desktop. 

ATTENTION: 

The module must be booted as IP subscriber.

ATTENTION: Function must also be activated in CCT 800

This function must also be activated in CCT 800.

A

B

A

B

Summary of Contents for C-TS8210VI

Page 1: ...station TS 8210V I MANUAL VERSION 1 1 0418 This manual refers to software version Intercom Client for Windows 1 3 PRODUCT MANUAL ENGLISH Touchscreenstation TS 8210V I MANUAL VERSION 1 1 0418 PRODUCT MANUAL ENGLISH ...

Page 2: ... respon sibility of the operating company of the transmission path and therefore the manufacturer cannot be re sponsible in any manner for errors and problems which result from problems or malfunctioning of the transmission path It is not allowed to copy any text of this document without permission of COMMEND INTERNATIONAL GMBH The technical data contained herein has been provided solely for infor...

Page 3: ...2 The outdoor touch screen station by Commend 5 3 Technical specifications 6 3 1 Technical data 6 3 2 System requirements 7 3 3 Network requirements 7 3 4 Extent of supply 8 3 5 Licences 8 3 6 Line length in LAN 8 3 7 Dimensions 9 4 Installation 12 4 1 Mounting 12 4 2 Connection 16 5 Configuration 17 5 1 Start up 17 6 Appendix 22 6 1 Optional Configuration of the camera 22 7 Technical support 23 ...

Page 4: ...ll not be disposed of together with household or com mercial waste The directive 2012 19 EU on waste electrical and electronical equipment WEEE is ap plicable in the European Union member states When installing and handling ESD precautions must be observed ATTENTION This information box addresses all necessary configuration options and actions which will allow error free operation In addition this...

Page 5: ...ouch screen station a pleasure to use The entire range of powerful Commend Intercom func tions is never more than a simple tap of the finger away What is more built in powerful 16 kHz technology ensures brilliant speech quality and crystal clear intelligibility at the highest level Vandal resistant for outdoor use The outdoor touch screen station has a vandal resistant design in accordance with IK...

Page 6: ... states Output 2 relay outputs switch over contacts max 60 W DC 37 5 VA AC max 2 A max 60 VDC 30 VAC expected life min 5 x 104 2A 105 1A Line input for feed in audio e g music radio conference nominal level 0 dBu 0 775 V at 10 kΩ Power of supply 1 external power supply recommended power supply PA30W12V 12 VDC min 2 5 A 10 16 VDC not included in extent of supply Cabling min Cat 5 Transmission bandw...

Page 7: ...tration of an TS 8210V I is possible Communication from the software IP Station Config is done via port 16399 cannot be con figured Communication from the TS 8210V I to the Intercom Server UDP protocol is done via port 16400 configurable By default the Windows firewall is activated In case of changes of the Intercom Client e g port configuration modifications of the firewall settings may be necess...

Page 8: ...ercom Clients Direct dialling licence Each licence activates one direct dialling module with 12 direct dialling buttons in phone There is a maximum of 8 direct dialling modules which can be used per Intercom Client L ICCDDA Licence for one direct dialling module L ICCDDA 4 Licence for four direct dialling modules L ICCDDA 8 Licence for eight direct dialling modules PRO5U licence required Video mon...

Page 9: ...Touch screen station TS 8210V I 1 1 0418 9 3 7 Dimensions 3 7 1 Front panel TS 8210V I Measuring units in mm in not to scale 240 9 45 360 14 17 139 5 47 224 8 83 52 2 04 ...

Page 10: ... 8210V I 10 1 1 0418 3 7 2 Flush mount kit TSFB 10V accessory Measuring units in mm in not to scale 3 0 12 39 1 54 45 1 77 336 13 23 360 14 17 380 14 96 348 13 70 220 8 66 200 7 87 240 9 45 227 8 94 2 0 4 0 80 3 15 270 10 63 ...

Page 11: ...on TS 8210V I 1 1 0418 11 3 7 3 Surface mount kit TSSH 10V accessory Measuring units in mm in not to scale 80 3 15 270 10 63 340 13 39 170 6 69 240 9 45 360 14 17 3 0 12 40 1 57 45 1 77 1 0 04 22 0 87 130 5 12 23 5 0 93 ...

Page 12: ...unlight For flush mounting the flush mount kit TSFB 10V is required available separately For surface mounting the surface mount kit TSSH 10V is required available separately Observe the country specific standards for installation mounting and configuration When opening the station ESD precautions must be observed The station may only be opened by authorised service engineers Ensure the correct mou...

Page 13: ...d flush with the wall Ensure the correct mounting direction The microphone has to be located at the bottom edge of the station and it may not be covered Sealing material for the space between the wall and mounting box must be obtained from other sources 2 Fix the flush mount box the spacers and the mounting brackets into place with screws 2a To prepare for plastering it is recommended to fix the flush...

Page 14: ...g kit Note The flush mount box has to be mounted flush with the wall Ensure the correct mounting direction The microphone must be located at the bottom edge of the station and it may not be covered Sealing material for the space between the wall and mounting box must be obtained from other sources For the installation of cable grommets see illustration Note Use a separate grommet for each cable 1 2 ...

Page 15: ...f the surface mount box is used the cable grommet from the front panel box must be used not pictured Note Cable grommets for the surface mount box must be ordered separately 2b 2b Mounting using mounting kit Note The cable inlet must be on the bottom of the surface mount kit Ensure the correct mounting direction The microphone must be located at the bottom edge of the station and it may not be cov...

Page 16: ...cabling The device does not support PoE Functional earth must be connected Use the snap on ferrite on the specified section of the Ethernet cable ATTENTION ET 908H The module ET 908H must not be removed or replaced ET 908H board Recommended cable routing Functional earth Power supply Min Cat 5 External power supply 12 VDC min 2 5 A 10 16 VDC RJ45 plug Snap on ferrite Cable tie ...

Page 17: ... mation Touch screen station on page 19 3 To leave the kiosk mode click OK The login screen opens Configuration with the Intercom Client 1 In the login screen select the user Admin to switch to the administrator mode 2 As soon as the admin user is logged in the password has to be changed Follow the instruc tions on the screen ATTENTION Disconnect the device from the internet To avoid unintended pr...

Page 18: ...onfigure the built in module ET 908H via IP Station Config see IP Station Config on page 20 5 1 3 CCT 800 Settings 1 Open the program CCT 800 2 Configure the module ET 908H and the Intercom Client via CCT 800 see CCT 800 on page 21 NOTE When using a cam server To change the camera configuration see Configuration of the camera on page 22 All further information concerning the settings of the Web vi...

Page 19: ...der top right bottom right top left bottom left see following illustration 2 To leave the kiosk mode click OK The login screen opens Modification of the touch points Depending on customer requirements the combination of touch points to end the Web View can be changed It is possible to move or delete individual points or to add new ones The Touch Points are defined in the following section of the s...

Page 20: ...nnot be configured 5 In the field Card IP enter the IP address of the IP subscriber card that shall be allocated to this IP subscriber 6 In the field Port the standard destination port number can be entered by default 16400 The port numbers must only be changed for special configurations with NAT 7 With activated DHCP activate the checkbox DYN in order to activate the dynamic registra tion via the...

Page 21: ...8H and Intercom Client Subscriber Station properties IP Terminals tab Common In the column Terminal IP Adress enter the IP Adress of the module ET 908H and the In tercom Client If DHCP is active in IP Station Config activate the checkbox Dynamic registration Subscriber Bonding In the drop down menu Slave 1 assign the call number of the Intercom Client to the Mod ule ET 908H Configuration camera Su...

Page 22: ...rientation Then the camera image is clipped according to the aspect ratio of Video size The resulting image is then enlarged to the same ratio Extend on left side Extend on right side and Extend on both sides The camera image is minimized proportionally and the resulting empty space is coloured black Select USB camera optional For the display of the camera picture the USB camera of the Outdoor Tou...

Page 23: ...Touch screen station TS 8210V I 1 1 0418 23 7 Technical support More information about our products and services can be found at www commend com ...

Reviews: