![Commend C-EE8999-KIT Product Manual Download Page 21](http://html1.mh-extra.com/html/commend/c-ee8999-kit/c-ee8999-kit_product-manual_2643002021.webp)
Industrial Stations EE 8000
Connection and Settings
3.1/0614
21
Power Supply
24 – 42 V AC; connection to terminals “PWR1“ and “PWR2“.
22 – 60 V DC; connection to terminals “PWR1“ and “PWR2“.
Attention:
The precautions for handling with 60 V direct current must be observed!
Power consumption max. 40 VA (40 W)
Power switch of EC 300: must be set for external supply:
Relay Outputs
The terminals OUT1 / OUT1 as well as OUT2 / OUT2 are operating as relay outputs (changeover
contacts, OUT as make-contact, OUT as break-contact).
Connection EE 8999S
The expansion housing EE 8999S can be connected to the EE 8999M by means of the connection cable
which is delivered with the EE 8999S.
In the same way a 2nd EE 8999S is connected to the 1st EE 8999S.
Note:
It is only possible to combine two EE 8999S with one EE 8999M.