3. Before Use
✽
Wiring Lobby phone and Security Station Phone :
1. For 481 System (Coaxial Cable) : Common 8 wires that are 3 ch 1
channel with "Balance Type".
2. For Gateview System (UTP Cable) : Common 4 wires with 1 channel.
✽
Wiring Lobby phone and Household unit monitor :
1. For 481 System (Coaxial Cable) : Common 4 wires that include audio and video
via coaxial cable.
2. Gateview System (UTP Cable) : Common 8 wires (Common 6 wires + Video 2
wires) that include audio and video via UTP cable and the video shall be
connected by "in/out" method.
✽
Any short-circuits and/or disconnection may cause product damage. Please check
the wires before installation.
✽
It is recommended to install one each of Lobby phone, Security Station phone,
and Household unit monitor to check the functionality before initiating overall
products installations.
✽
RF Card Keys may be registered up to 2,048 keys (if not connected to computer)
✽
Failing Management Password, Building Password, and Unit Password more than
3 times will cause an automatic notice to Security Station. Attempts to initiate an
entrance with unregistered RF Card Key will cause an automatic notice to Security
Station as well.
[WARNING]
When power is initially turned on, please be sure that none of the buttons are
pressed.