5

3-2. Important function 

Starting OLED display (Power ON OLED display) 

RF/ID Receiver 

(Optional) 

When open door by wireless card key, please tag it to this points.(See bellow
photo). 
"Open door" message and Icon will be displayed in OLED.   

Call Button 

(E : Press) 

Call unit (House). 

Program button 

(P : Program) 

Call program menu button. 

(Press and hold over 5 sec, then menu will be activated) 

www.safemag.ru

www.safemag.ru

Summary of Contents for DR-2AG/RF

Page 1: ...any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety before using a p...

Page 2: ...ced door forwarding to SecuMAX 31 18 Selecting the Wiring Method 32 19 Registration of Household Unit Number 33 20 Checking Status of Household Units 35 21 Setting the Keypad LED Option 37 22 Activati...

Page 3: ...e an electric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the socket when not us...

Page 4: ...lease don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the designated conne...

Page 5: ...ay 3 RFID card receiver Name Searching button Menu Page Button Up Down scroll button Program Button 6 Call Button 7 Number button 8 Cancel Button 9 C MIC 10 Electric Key Button 11 Line connecting butt...

Page 6: ...pen door by wireless card key please tag it to this points See bellow photo Open door message and Icon will be displayed in OLED Call Button E Press Call unit House Program button P Program Call progr...

Page 7: ...press it Reset button Reset security guard password or management office password When forgot password press reset button which is on back side of products 15 Press Hold over 3 sec after power on Ele...

Page 8: ...1 Password for any household Use the identifying household password function 6 1 to confirm the password methods to confirm password shall be requested to the Management office or Security cPress 2 2...

Page 9: ...Password is 4321 4 2 Password for any buildings Building Password A common password for a corresponding building Factory default for the Building Password is 1234 4 3 Password for any household units...

Page 10: ...nt Password P old Password E New Password E Password must be 4 digits 0000 1234 4321 can t be used as Password Press program button P Press old management default Password 4 3 2 1 Press call button E...

Page 11: ...0000 1234 4321 can t be used as Password Press program button P Press old building default Password 4 3 2 1 Press call button E Press 1 Set up building Password button Press call button E Press new P...

Page 12: ...cause of Interphone types Some model of Interphone can change Password in house Please check manual of interphone Press program button K Press 20 Set unit Password Number Press call button E Press hou...

Page 13: ...Password E 16 E Household Unit Number E Press program button P Press management Password Press call button E Press 16 Set ID Number function key Press call button E Press new ID Number Press call but...

Page 14: ...lobby panel can be installed for one building 7 1 Set building Number in Lobby panel interphone P Management Password E 2 E Building Number E Press program button P Press management Password Press ca...

Page 15: ...t Password E 3 E ID E Press program button P Press management Password Press call button E Press 3 Set ID Number function key Press call button E Press new ID Number Press call button E ID Number has...

Page 16: ...t of wireless card key Press down the P button Press Management Passwords Press Call Button E Press number 9 for the test of wireless card key Press Call Button E The card registration number will be...

Page 17: ...erences Up to 2048 cards can be registered if not to connect with SecuMAX 8 2 RF card key input way P Management Password E 10 E Place card close to the RF ID receiver X cancel www safemag ru www safe...

Page 18: ...ds X Cancel Press Program Button P Press Management Password Press Call Button E Press number 12 separate delete number Press Call Button E Place the card key close to the RF ID receiver Press down th...

Page 19: ...k the cards X Cancel Press Program Button P Press Management Password Press Call Button E Press number 13 registration check Press Call Button E Place the card key close to the RF ID receiver Press do...

Page 20: ...ton Press Management Password Press down E button Press number 11 all delete number Press Call Button E Press Call Button E one more The number on OLED display to be changed Press down X button if to...

Page 21: ...1 E Unlimited RF Cards can be registered Press down P button Press Management Password Press down E button Press number 19 capacity change number Press Call Button E Select mode between numbers 0 and...

Page 22: ...ata transmission Press Call Button E Press number destination lobby phone number Press Call Button E References Data can be sent only if the mode 99 in the program number 23 is selected executed the p...

Page 23: ...a reception Press Call Button E Press number source lobby phone number Press Call Button E References Data can be received only if the mode 99 in the program number 23 is selected executed the process...

Page 24: ...uMAX enabled This function is to set the door release by internal sensor information forwarding to SecuMAX Press Program Button P Press Management Passwords Press Call Button E for call Press number 2...

Page 25: ...am Button P Press Management Passwords Press Call Button E Press number 5 for door opening hours setting Press Call Button E Select door opening hours Opening hours is in the middle of 1 25 seconds Pr...

Page 26: ...1 line 2 line input 0102 This function is only for specified line call not for entire house call Press Program Button P Press Management Passwords Press Call Button E Press number 21 for call line by...

Page 27: ...call mode This function is to set the automatic calling to the security station when the failure of Password occurs more than 3 times Press Program Button P Press Management Passwords Press Call Butt...

Page 28: ...set the recall sound of house guard station at the common entrance Press Program Button P Press Management Passwords Press Call Button E for call Press number 7 for selection of call tones Press Call...

Page 29: ...Call ring enabled This function sets number of call ring repetition when a call is made to any households or security office Press Program Button P Press Management Password Press Call Button E Press...

Page 30: ...ecuMAX enabled This function is to set the door release by internal sensor information forwarding to SecuMAX Press Program Button P Press Management Passwords Press Call Button E for call Press number...

Page 31: ...ed opening by SecuMAX disabled This function is to set the opening the Main Entrance door forced opening by SecuMAX Press Program Button P Press Management Passwords Press Call Button E for call Press...

Page 32: ...otice to be forced door forwarding to SecuMAX If you use this function you should set the time more 1 second than the door close time The notice forwarding to SecuMAX after 2 seconds when to be forced...

Page 33: ...hod If common 6 wire method selected there will be no signal sent to all household units Press Program Button P Press Management Password Press Call Button E Press 6 number six Press Call Button E Sel...

Page 34: ...from the monitor number of household E serial number E This method applies to the case that there is no security station installed Calling security from the monitor will direct the call to the lobby p...

Page 35: ...done press Cancel Button X to exit References This method applies to the case that it is possible to install Slave phones Master videophone s Multi Sub Number is number 0 zero Sub videophone s Multi...

Page 36: ...35 20 Checking Status of Household Units P Management password E 14 Unit Number E serial number E This function is to check the status of installed in each household unit www safemag ru www safemag ru...

Page 37: ...peat 6 7 procedures As the status check is done press Cancel Button X to exit Status of household unit indication Standby standby mode applies even when the household unit monitor is communicating wit...

Page 38: ...FF Press the program button P Please set up the Management password Press the call button E Press number 20 setting number of Electronic key Press the call button E Select mode by numbers 0 or 1 0 Whi...

Page 39: ...31 0 E Electronic Key Password disabled This function is to enable or disable the password access Press Program Button P Press Management Password Press Call Button E Press 31 number thirty one Press...

Page 40: ...e adjustment of Beep Voice volume Press Program Button P Press Management Password Press Call Button E Press 30 number thirty Press Call Button E Press desirable Beep Volume 1 2 and then desirable Voi...

Page 41: ...ber of caller name Press Call Button E Press number destination lobby phone number Press Call Button E References Data can be send only if the mode 99 in the program number 23 is selected executed the...

Page 42: ...number of name data Press Call Button E Press number source lobby phone number Press Call Button E References Data can be received only if the mode 99 in the program number 23 is selected executed the...

Page 43: ...26 1 Setting the Door Release by Building Password P Management Password E 28 1 E Door release by Building Password enabled P Management Password E 28 0 E Door release by Building Password disabled T...

Page 44: ...43 26 2 Using a door release by Building Password function www safemag ru www safemag ru...

Page 45: ...44 27 When you want to call a household 1 called to a household 1 called to a household www safemag ru www safemag ru...

Page 46: ...45 28 When you want to call a Guard Station 29 Door Release by Unit Password www safemag ru www safemag ru...

Page 47: ...2 P Management Password E 3 E Lobby Phone Number E Lobby Phone Number Registration 3 P Management Password E 28 E Door Release Function enabled disabled 00 Disabled 01 Enabled 4 P Management Password...

Page 48: ...rd Station Other settings 1 P Management Password E 5 E Door Release Duration Setting 2 P Management Password E 6 E Selecting Wiring Methods 04 Common 4 wires 06 Common 6 wires 3 P Management Password...

Page 49: ...48 31 Wiring Information 1 Guard interphone GateView GuardStation 481 GuardStation www safemag ru www safemag ru...

Page 50: ...49 2 Sensor connection method www safemag ru www safemag ru...

Page 51: ...50 3 entrance interphone DR 2AG Caution If installed outdoor it requires extra molding for water proof and rainshield www safemag ru www safemag ru...

Page 52: ...51 4 System schematic www safemag ru www safemag ru...

Page 53: ...CONN 6PX300 Wiring Connector 2 POWER CORD WHI Adaptor Cord 1 SCREW FHM 4X40 SUS NI 34 Specifications and Features Installation Flush Mount Type installation Model DR 2AG RF1 UTP Cable 0 5 Floor Distri...

Page 54: ...nge Under 47 5mV m within 10 meter radius Power 12V Emission Type A1D Number of Channel 1 Channel Modulation method ASK Communication method Simplex Operation Method Temperature 10 C tested up to 40 C...

Page 55: ...daewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2013 12 104 PM132AGRF110 www safemag ru www...