Subject to change
COMM-TEC GMBH
SIEMENSSTRASSE 14 TEL: +49 7161-3000-0
WWW.COMM-TEC.DE
D-73066 UHINGEN
FAX: +49 7161-3000-400
2.
Connection type (bus or ring connection)
-
After configuring network and sequence settings, the device is ready to use. There are two ways how you can set up
a DaisyNET installation: bus type (standard) or ring type. If you want to use the ring-type connection, connect the
HDBaseT output at the last device in the chain with the HDBaseT input of the first device in the chain.
3.
Setting the output resolution
The rotary switch on the front panel lets you chose the scaling resolution for the HDMI output.
Note: The signal on the HDBaseT output is presented in the original, unscaled format of the source.
Position Functions
0
Auto Scaler setting via EDID
1
Set 1024 x 768@60Hz as output resolution
2
Set 1280 x 720@60Hz as output resolution
3
Set 1280 x 800@60Hz as output resolution
4
Set 1280 x 1024@60Hz as output resolution
5
Set 1920 x 1080@60Hz as output resolution
6
Set 1920 x 1200@60Hz as output resolution
7
Set 3840 x 2160@30Hz as output resolution
8
Set 3840 x 2160@60Hz as output resolution
9
Set resolution via Web interface or API Control
Note: Scaler configuration by WEB or API control is only effective when the rotary switch is set to position 9
4.
Further information
You can download the manual, firmware updates etc. from our website www.daisynet.de
COMM-TEC / DWN / 22.11.2017
TRX1
TRX2
SRX1