background image

User Manual

DA-14C-Dual-2

COMM-TEC GMBH

SIEMENSSTRASSE 14

T49(0)7161/3000-0

WWW.COMM-TEC.DE

D-73066 UHINGEN

T49(0)7161/3000-333

[email protected]

2.0 Power supply

DA-14C-Dual-2 unit should be powered only with the provided AC/AC adapter.
The adapter must be inserted in a 220-240 Volt AC / 50 Hz outlet.

Caution

Use of any other type of power adapter can damage the unit.

Be aware of the risks of an electric shock.

Only qualified personnel should perform installations

.

3.0 Settings

The unit has no internal settings.

At the rear side of the unit are 5 user programmable DIP-switches.

1 IN2 DC

:In pos. ON input IN2 is DC coupled

2 IN2 75 

:In pos. ON input IN2 is 75 

 terminated

3 IN1+IN2 :In pos. ON the two inputs are linked

4 IN1 75 

:In pos. ON input IN1 is 75 

 terminated

5 IN1 DC

:In pos. ON input IN1 is DC coupled

Note

The DC coupling is recommended when the

input signal is clamped

.

The factory configuration at shipping is as follows:
1 IN2 DC

:OFF

2 IN2 75 

:ON

3 IN1+IN2

:OFF

4 IN1 75 

:ON

5 IN1 DC

:OFF

Summary of Contents for DA-14C-Dual-2

Page 1: ...2 Dual 1 to 4 Video Distribution Amplifier User Manual English COMM TEC GmbH Siemensstr 14 D 73066 Uhingen Tel 49 7161 3000 0 Fax 49 7161 3000 333 www comm tec de Version A0 July 2007 DBA Copyright b...

Page 2: ...nection with the use of or inability to use COMM TEC products COMM TEC reserves the right to modify or discontinue designs specifications warranties and policies without notice 1 0 Overview Thank you...

Page 3: ...ks of an electric shock Only qualified personnel should perform installations 3 0 Settings The unit has no internal settings At the rear side of the unit are 5 user programmable DIP switches 1 IN2 DC...

Page 4: ...DIP switches 2 and 4 in ON position d Set the DIP switch 3 in OFF position e Set as desired the two DIP switches 1 and 5 to establish the DC or AC coupling f Connect the destinations g Power the DA 1...

Page 5: ...tcher set the DIP switches 3 IN1 IN2 and 4 IN1 75ohm in ON position Set the DIP switch 2 IN2 75ohm in OFF position and connect the input signal to the BNC IN1 4 4 Linking inputs with T adapter To perf...

Page 6: ...of the cable run For the best results use RG59 B U coax cable For calibration of the system proceed as follows a Using a TV generator generate a MULTIBURST signal and send it to the DA 14C Dual 2 by t...

Page 7: ...ency response 0 1 dB at 10 MHz 3 dB at 60 MHz Delay 15 ns Differential gain 0 2 Differential phase 0 8 Hum noise 90 dB unweighted Crosstalk two sections 60 dB at 5 MHz Power 9 Volt AC 500 mA external...

Page 8: ...terials Authorization RMA number Merchandise will not be accepted without a RMA number When returning a product to COMM TEC in Uhingen for repair please comply with the following instructions Shipping...

Reviews: