4. Battery and Charger
14
4.1 Charger Requirements
The charger should only be used for charging the batteries. Do not
use your wheelchair while it is charging.
Charger Technical Data
Input voltage: AC220V (110V) ±10%
Output voltage: 24V/DC Output current: 1.5~5A
Ingress protection level: IPX1
Meets requirement: GB 4706.1-2005 and GB 4706.18-2005
4.2 Charger Use and Care
IMPORTANT:
-
A full charge requires between 6 to 10 hours, do not overcharge
more than 24 hours.
- To prevent shortening your battery’s life, charge the battery at least
once per month when the wheelchair is not being used.
- Do not stop charging until the charging process is finished.
- Repeat use of less than fully charged batteries will shorten the life
cycle of your battery.
- When battery is fully charged, the power indicator will turn green. Do
not stop charging before fully charged this indicator is lit.
- After charging is complete, ensure to turn off the power supply other-
wise the battery will discharge slowly.
- Do not charge more than 24 hours. Over-charging is dangerous.
Follow These Rules to Avoid Issues with Chargers
- The electric wheelchair doesn’t include a charger, please use nation-
al standard charger with output voltage of 24V/DC 1.5A~5A.
- The charger should be well ventilated at all times during charging.
- Do not expose the wheelchair to sunlight and humid environment.
- While charging, the temperature range should be between 10 to 50
degrees of celsius.
- If charged at temperatures outside of this range, the battery can be
damaged.
- Never use or sit on the electric wheelchair when charging.