1. General information
This manual provides information relating to the installation, utilization, and maintenance of our filtration
system. We recommend that you read this manual in its entirety and keep it for future reference.
The pump included with the filtration system is a horizontal, self-priming centrifugal pump. For the pump to
function correctly, the water temperature must not exceed 35
℃
/95
℉
. The materials used in the pump have
undergone stringent hydraulic testing and electrical inspections. The filter tank included in the filtration system
consists of high-grade polypropylene (PP). It is manufactured as a single unit and is corrosion resistant and
resistant to commercially available swimming pool chemicals. (Prerequisite: Compliance with the standard
recommended specifications for the pH- and chlorine value). It is equipped with a tank drainage system. The
filter tank comes ready to attach with an approved filter pump with hair and lint basket, and a plastic base for
ready on- site mounting.
Read this manual carefully before installation. The filtration system and pump must be installed in accordance
with all federal and local codes and standards in effect for the area of installation. We decline all responsibility
for the consequences of failure to comply with the installation instructions. We recommend that you comply
with the power source instructions to avoid overloading the pump motor and/or electric shock. Your pool filter
system has been engineered and manufactured to our highest standard for dependability, ease of operation
and safety. With proper care, it will give you years of durable, trouble-free performance.
Filter material is not included.
1.1. Safety notes
Your filter pump was constructed and tested and left the manufacturing plant in technically operational
condition. To maintain this condition and ensure safe operation, the user should observe the notes and product
information contained in this technical manual. If there is any indication that safe operation is no longer
possible, the device is to be disconnected from the power supply and secured against accidental use.
This is the case when:
▪
The device has visible damage.
▪
The device no longer appears functional.
▪
After long periods of storage in poor conditions.
1.2.
Technical data and specifications
The recommended filter run time is twice a day for 4 to 5 hours with floor vacuum cleaning as needed.
The major components of your system are:
▪
Filter pump
▪
Filter tank
▪
Tank lid
▪
Lid V-band with bolt and nut
▪
Base plate
▪
Hose with fittings