MWD5 OPERATION SETTINGS - HYDRONIC

IMPORTANT SETTINGS TO ADJUST & CHECK WITH EVERY MWD5

Adaptive Function – 

Turn OFF

Press ;
> Menu
> Arrow down
> Engineer Settings

Adaptive Function

> Turn OFF
> Tick

Open Window - 

Turn OFF  

Press ; 
>

 Open Window

> Turn OFF
> Tick

Temp Scale - Recommend adjust to 5°C - 40 °C   
Press ; 
> Arrow down

Temp.Scale

> Tick [Set the min & max temperature]
> 5 °C [Min. Temperature Scale]
> Tick
> 40 °C [Max. Temperature Scale]
> Tick

> 5 °C [Min. Temperature Limit]
> Tick
> 40 °C [Max. Temperature Limit]
> Tick

> Arrow left to exit menu

Open Window - Turn OFF

The thermostat can detect an open window 
by registering a rapid drop in room 
temperature. With the function enabled, the 
thermostat shuts off the floor heating for 30 
minutes.

Adaptive Function - Turn OFF

This feature enables the room to reach the set 
temperature at a set time.
Adaptive function calculates the heat up time 
and will turn the system on or off to achieve the 
set temperature at the set time.

Eg. Thermostat calculates it must turn on at 
5.00am 

to be at 25°C at 6am

, as opposed to 

turning on at 6am to heat to 25 °C.

Temp Scale - Adjust to 5°C

This option allows you to set the minimum and 
maximum temperature to which the 
thermostat can be set.

PRESET HEATING SCHEDULE

Monday – Friday  [Work Days]       ON at 6am - 25°C
                                                           Setback at 9am - 20°C
                                                           ON at 5pm - 25°C
                                                           Setback  at 10.00pm - 20°C

RUNNING GUIDELINES 

Gas systems

 are ideal for on-demand heat. Gas boilers are efficient any time of day, quiet to run and billed at a flat rate. 

Heat Pump

 systems are at the fore-front of hydronic heating and can be highly cost efficient to run. Heat pumps require a   

range of considerations when running for example, the location, appropriate time of use and efficient times to run.  

In-Slab

 installations are typically large and have excellent thermal mass. Initially, the slab may take a few days to warm 

and then only requires to be topped up to create an all day warmth. Allow 2-4 hours for the slab to top up.

In-Screed

 installations typically heat up in around 2-3 hrs depending on the screed thickness. Screeds will retain the heat 

for a few hour and by keeping doors closed and windows shut, retain the warmth for an efficient and comfortable room 
temperature. Programme the in-screed heating to run when at home, based on your lifestyle.

Under-Timber

 installations warm the small air space below the timber allowing this warmth to gently rise into the room. 

Under timber heating has a maximum temperature limit and may require supplemental heating to warm the room.      

Radiator

 systems are ideal for on-demand heat. One 

master thermostat

 and radiator typically control the whole system 

based on the air temperature. Each additional radiator is then fitted with a tempering valve that is manually adjusted to 
regulate each room. Radiators will warm a room in around 1-2 hours, programme the radiator heating to run when at 
home, based on your lifestyle.

Saturday - Sunday [Home Days]   ON at 8am - 25°C

                                                     Setback at 11pm - 20°C 

Summary of Contents for MWD5

Page 1: ... DOWN periods the floor does not turn OFF but programs the floor temperature to a setback temperature The floor is heating when the LCD display temperature turns red Thermostats can be vertically or horizontally flush mounted and have a 2 pole isolator with 16A output relay A Comfort Heat heating system has been installed in your floor Floor heating warms from the ground up providing an unparallel...

Page 2: ...G GUIDELINES Gas systems are ideal for on demand heat Gas boilers are efficient any time of day quiet to run and billed at a flat rate Heat Pump systems are at the fore front of hydronic heating and can be highly cost efficient to run Heat pumps require a range of considerations when running for example the location appropriate time of use and efficient times to run In Slab installations are typic...

Page 3: ...hanging any of its settings ACTIVATING CHILD LOCK Press Menu User Settings Child Lock Toggle ON Tick to Confirm Arrow back to Home Screen OPEN WHEN CHILD LOCK IS ON Draw an L on the screen in a single stroke without lifting your finger App Control App Control MENU STRUCTURE TROUBLE SHOOTING If an error message occurs the thermostat will display one of the following errors E0 Internal failure The t...

Page 4: ... right Tick all work days every day is dark blue Arrow right Tick to confirm no home days are ticked Arrow left back Events per Day Arrow right Tick 4 events per day Tick to confirm Event Schedule Work Day Wake Up 21 C 6 00 Touch to adjust temperature Tick Adjust time Tick to confirm Arrow right Work Day Leave Home 10 C 8 00 Touch to adjust temperature Tick Adjust time Tick to confirm Arrow right ...

Page 5: ...rature Tick Adjust time Tick to confirm Arrow right Work Day Come Home 21 C 20 00 Touch to adjust temperature Tick Adjust time Tick to confirm Arrow right Work Day Go To Sleep 5 C 22 00 Touch to adjust temperature Tick Adjust time Tick to confirm Arrow right Arrow left to exit menu Programming your floor heating schedule is a completely individual decision based on your lifestyle and personal pref...

Page 6: ...Touch to adjust temperature Tick Adjust time Tick to confirm Arrow right Work Day Come Home 22 C 17 00 Touch to adjust temperature Tick Adjust time Tick to confirm Arrow right Work Day Go To Sleep 12 C 21 00 Touch to adjust temperature Tick Adjust time Tick to confirm Arrow right MANUAL HEATING The MWD5 will always default to the programmed settings You can override these settings by turning the t...

Page 7: ...o detect available networks If your WIFI network does not appear turn your router on off and repeat this process until your network appears on the list 4 Select your WiFi network and arrow right 5 Enter WiFi password Left button flips between upper case lower case numbers and symbols Press up and down arrow buttons to scroll and press highlighted character to select 6 Press the Tick to complete Th...

Page 8: ... on App for final connection 25 Leave Mode To start adjusting temperature and settings press Leave if prompted ADD ZONES THERMOSTATS SWATT App divides your heated areas into zones and within each zone is one or multiply thermostats You can programme the same schedule and set the temperature of the whole zone or control each thermostat temperature independently 26 Press Menu in App 27 Press Manage ...

Page 9: ...nu Set Up Schedule Select Zone Can only program zones not a single thermostat Press M on top row to select Monday 1 Event Start time 5 30AM 24 28 C 2 Event Activate toggle Start time 8 30AM 17 C 3 Event Activate toggle Start time 5 00PM 24 28 C 4 Event Activate toggle Start time 10 00PM 17 C Press Copy Schedule Tick Tues Wed Thurs Fri Sat Sun Press OK to confirm days Press OK to confirm Schedule T...

Reviews: