INsTAllATIoN
Continued
CAUTION: Never connect pro
-
pane/LP ireplace directly to the
propane/LP supply. This ireplace
requires an external regulator
(not supplied). Install the external
regulator between the ireplace
and propane/LP supply.
WARNING: Never connect
natural gas ireplace to private
(non-utility) gas wells. This
gas is commonly known as
wellhead gas.
For propane/LP units, installer must supply
an external regulator. The external regulator
will reduce incoming gas pressure. You must
reduce incoming gas pressure to between
11" and 14" of water. If you do not reduce
incoming gas pressure, ireplace regulator
damage could occur. Install external regula-
tor with the vent pointing down as shown in
Figure 21. Pointing the vent down protects it
from freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Inter
-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" or greater diameter to allow
proper gas volume to ireplace.
If pipe is too small, undue loss
of volume will occur.
Propane/LP
Supply Tank
External
Regulator
Figure 21- External Regulator with Vent
Pointing Down
Vent
Pointing
Down
Extension Cord
Use extension cord if needed. The cord must
have a three-prong, grounding plug and a
three-hole receptacle. Make sure cord is in good
shape. It must be heavy enough to carry the
current needed. An undersized cord will cause
a drop in line voltage. This will result in loss of
power and overheating. Use a No. 16 AWG cord
for lengths less than 50 feet.
CONNECTING TO GAS SUPPLY
WARNING: This appliance
requires a 45° male lare itting
5/8"-18 UNF (Uniied National Fine
Thread) inlet connection and the
lexible gas line provided.
WARNING: A qualified
service person must connect
ireplace to gas supply. Follow
all local codes.
Figure 20 - Installing Blower Bracket
Assembly
3
2
1
Blower Bracket
Assembly
Screw
Wire Harness
Power
Cord
Valve
Cover
Shield
Box Cover
Wire
Harness
Switch Plate
Switch
Clamp Connector
(not included)
Outlet
Receptacle
Blue
Red
Plastic
Wire Strap