Comfort Stat CP1717 Owner'S Manual Download Page 6

Ÿ

Insert the tabs  on top  of the thermostat body into the slots  at the top  of the  wallplate. Press the bottom  of the thermostat  body into the snap  on the  bottom  of the 

wallplate. Refer to Figure 2. (NOTE: Do not force the thermostat onto the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat 

may not work.) 

Ÿ

 Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment. 

Ÿ

 Switch on the main power at the panel or furnace.

 

Wiring Diagrams 

X­No Connection 

Selector Switches

 

In order for this thermostat to control your system, the system type must be specified by the selector switches on the printed circuit board inside the thermostat. There 

is also a selector switch for your choice of Fahrenheit or Celsius temperature display. See figure 6. 

Ÿ

 Heating System Selector (HG – HE switch) 

The factory position for this switch is in the “HG” position. Leave it in this position if you have a gas furnace or an oil burner. If you have an electric furnace, test to see 

whether the Heat  and Fan come  on  as  expected  after installation. If the  Fan  operation is  normal, leave it in the “HG” position. If the Fan does not come  on within  a 

minute of the thermostat calling for heating, change the switch position to “HE”. The system selector has no effect in the cooling mode. 

NOTE: “HG” position is for gas and most other systems. “HE” position is for certain electric systems having a fan relay. 

Ÿ

 System Selector (STANDARD – HEAT PUMP switch) 

Rh/B 

Rc/O

 

Wallplate 
Terminals 

Jumper 

Fan 
Relay 

Heat Relay 
or Valve 

Cool 
Contactor 

Heat/Cool 
24V Supply 

System 
Selector 

STD 

HP 

Fan 
Relay 

Reversing 
Valve 

Compressor 
Contactor

 

Wallplate 
Terminals 

Rh/B 

Rc/O 

System 
Selector 

HP 

STD 

Fan 
Relay 

R

 

Wallplate 
Terminals 

Heat 24V 
Supply 

Cool 
Contactor 

Heat Relay 
or Valve 

Cool 24V 
Supply

 

No Jumper 

Rh/B 

Rc/O 

System 
Selector 

HP 

STD

 

Jumper 

24V 
Supply 

Heat 
Mode 

Cool 

Mode 

OR 

Heat 24V or 
Millivolt Supply 

Heat Relay 
or Valve

 

Wallplate 
Terminals 

R

 

Jumper 

Rh/B 

Rc/O 

System 
Selector 

HP 

STD

 

Wallplate 
Terminals 

System 
Selector 

Heat 24V 
Supply 

Heat Relay 
or Valve 

Rh/B 

Rc/O

 

Jumper 

HP 

STD 

Fan 
Relay

Fan 
Relay

 

Wallplate 
Terminals 

Cool 
Contactor 

Cool 24V 
Supply 

Rh/B 

Rc/O 

System 
Selector 

HP 

STD

 

Jumper 

4­Wire Heat/Cool System 

5­Wire/Heat Cool System 

Single­Stage Heat  Pump System 

2­Wire Heat Only System 

3­Wire Heat Only System 

3­Wire Cool Only System

 

Connect  to  proper  Reversing 

Valve Terminals. See Table A

Summary of Contents for CP1717

Page 1: ...d automatically cutoff in Cool mode if the temperature drops below 45 F 7 C 3 Compressor Protection This thermostat provides a 4 minute delay after shutting off the compressor before it can be restart...

Page 2: ...or will flash as a reminder to check your system s filter After changing or cleaning the system filter press and hold the Filter key for 3 seconds The display will blink and the counter will be reset...

Page 3: ...alkaline batteries even if you have recently replaced them Next Move the battery out hold any key then place the battery again You will need to reprogram your thermostat and confirm normal operation I...

Page 4: ...erminal on your existing thermostat IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard After labeling wires disconnect them from the existing thermostat Remove existing w...

Page 5: ...wallplate Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate See Figure 4 5 Ignore any wires which may be present but which were note connected to the old th...

Page 6: ...in the HG position If the Fan does not come on within a minute of the thermostat calling for heating change the switch position to HE The system selector has no effect in the cooling mode NOTE HG posi...

Page 7: ...ies Auto Fan Does Not Turn On Properly 1 Move HG HE selector to correct position 1 Check that the function switch is in the correct position HEAT or COOL 2 There may be as much as 4 mintue delay befor...