background image

15

105683

OWNER’S MANUAL

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

Burner does not light after ODS/pilot is lit

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Moisture/condensation noticed on windows

Heater produces a whistling noise when
burner is lit

Dark residue on logs or inside of fireplace

White powder residue forming within burner
box or on adjacent walls or furniture

REMEDY

1. Clean burner (see Cleaning and Mainte-

nance, page 13) or replace burner orifice

2. Contact local natural gas company
3. Replace burner orifice
4. Reconnect leads (see wiring diagram)

5. Replace battery in transmitter and receiver

1. Contact local natural gas company
2. Clean burner (see Cleaning and Mainte-

nance, page 13) or replace burner orifice

1. Clean burner (see Cleaning and Mainte-

nance, page 13) or replace burner orifice

2. Replace damaged burner
3. Replace gas control

1. Check burner for dirt and debris. If found,

clean burner (see Cleaning and Mainte-
nance, 
page 13)

2. Replace gas control
3. Problem will stop after a few hours of

operation

1. Refer to Air for Combustion and Ventila-

tion requirements (page 4)

1. Turn control knob to LO position and let

warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local natu-
ral gas company

3. Observe minimum installation clearances

(see pages 7 through 9)

4. Clean burner (see Cleaning and Mainte-

nance, page 13) or replace burner orifice

1. Properly locate logs (see Installing Logs,

page 10)

2. Eliminate source of drafts around heater

3. Clean out air holes at burner inlet. Peri-

odically repeat as needed

4. Remove blockage or replace burner

1. Turn heater off when using furniture pol-

ish, wax, carpet cleaners, or similar
products

POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Thermopile leads disconnected or im-

properly connected

5. Burners will not come on in remote position

1. Manifold pressure is too low
2. Burner orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective
3. Residues from manufacturing processes

and logs curing

1. Not enough combustion/ventilation air

1. Turning control knob to HI position when

burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

1. Improper log placement

2. Drafts or other air currents affecting

flame pattern

3. Air holes at burner inlet blocked

4. Burner flame holes blocked

1. When heated, vapors from furniture pol-

ish, wax, carpet cleaners, etc. turn into
white powder residue

www.desatech.com

Continued

Summary of Contents for S26NT

Page 1: ...appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s p...

Page 2: ...s ornausea Ifyouhavethesesigns theheater may not be working properly Get fresh air atonce Haveheaterserviced Somepeople are more affected by carbon monoxide than others These include pregnant women pe...

Page 3: ...inner pack 2 Tilt carton so that stove is upright 3 Remove protective side packaging 4 Slide stove out of carton 5 Remove protective plastic wrap 6 Remove screen by lifting and then pull ing forward...

Page 4: ...passagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilati...

Page 5: ...combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can suppo...

Page 6: ...r from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide tw...

Page 7: ...floor ceiling and adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor IMPORTANT You must maintain minimum wall an...

Page 8: ...ap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly INSTALLATION Continued CONNECTING...

Page 9: ...hutoff valve to gas supply Check reconnected fittings for leaks TestPressuresEqualToorLessThan 1 2 PSIG 1 Close manual shutoff valve see Fig ure 7 2 Pressurize supply piping system by ei ther using co...

Page 10: ...omblower motor if connected see Figure 12 4 Disconnect green ground wire from blower housing if connected by re moving screw holding wire terminal see Figure 12 5 Install one plastic bushing provided...

Page 11: ...next step 5 Turn control knob counterclockwise C clockwise to the PILOT position Press in control knob for five 5 sec onds see Figure 17 Note You may be running this heater for the first time after ho...

Page 12: ...ny comfort level between Hi and Lo The thermostatwillgraduallymodulatetheheat output and flame height from higher to lower settings or pilot in order to maintain the comfort level you select The ideal...

Page 13: ...t every 2 500 hours of operation or every three months Wealsorecommendthatyoukeeptheburner tubeandpilotassemblycleanandfreeofdust and dirt To clean these parts we recommend using compressed air no gre...

Page 14: ...ged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind ba...

Page 15: ...ntil air is removed from line Have gas line checked by local natu ral gas company 3 Observe minimum installation clearances see pages 7 through 9 4 Clean burner see Cleaning and Mainte nance page 13 o...

Page 16: ...e just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This i...

Page 17: ...t Hartsville SC 29550 7704 803 332 0191 Parts Department Cans Unlimited Inc P O Box 645 Taylor SC 29687 0013 All States 803 879 3009 1 800 845 5301 Parts Department Baltimore Electric 1348 Dixwell Ave...

Page 18: ...18 105683 VENT FREE NATURAL GAS PEDESTAL STOVE ILLUSTRATED PARTS BREAKDOWN S26NT 5 7 6 9 13 4 10 3 2 1 14 15 12 11 10 8...

Page 19: ...lot NG 1 3 098249 01 ODS Nut 2 4 105973 01 Burner Outlet Tube 1 5 105737 01 Injector Holder 1 6 102843 01 Burner Clip 1 7 099056 27 Burner Orifice Injector 1 8 101329 25 Gas Control Valve 1 9 L98305 0...

Page 20: ...20 105683 VENT FREE NATURAL GAS PEDESTAL STOVE ILLUSTRATED PARTS BREAKDOWN S26NT 1 4 13 3 2 14 7 16 15 11 18 10 5 6 9 8 17 12...

Page 21: ...tor 1 PARTS AVAILABLE NOT SHOWN 101054 01 Lighting Instructions Plate 1 100563 01 Warning Plate 1 104310 10 Information Video 1 104108 09 Touch Up Paint Kit 12 oz can 1 Thislistcontainsreplaceablepart...

Page 22: ...sedbyimproperinstallation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTEN...

Reviews: