VENTING INSTALLATION

Continued

  WARNING:  Do  not  recess 

vent termination into any wall. 

This will cause a fire hazard.

6. 

Noncombustible  Exterior  Wall:

  Posi

-

tion horizontal vent cap in the center of 7 

3

/

4

" round hole and attach to exterior wall 

with four wood screws provided. Before 
attaching vent cap to exterior wall, run a 
bead  of  non-hardening  mastic  (pliable 
sealant) around outside edges to make a 
seal between it and outside wall.

Note:

 

The  four  wood  screws  provided 

should be replaced with appropriate fas-
teners for stucco, brick, concrete or other 
types of sidings

.

 

Combustible  Exterior  Wall:

  For  vinyl 

siding, stucco or wood exteriors, a siding 
standoff  may  be  installed  between  vent 
cap and exterior wall. The siding standoff 
prevents excessive heat from damaging 
siding materials. Siding material must be 
cut  to  accommodate  standoff.  Bolt  vent 
cap  to  standoff.  Apply  non-hardening 
mastic around outside edge of standoff. 
Position  standoff/cap  assembly  in  the 
center of the 10" square hole and attach 
to exterior wall with wood screws provided 
(see Figure 11). Siding standoff must sit 
flush against exterior fascia material.

7. 

Combustible Exterior Wall Only:

 Slide 

wall  firestop  over  vent  pipe  before  con

-

necting  horizontal  run  to  vent  cap  (see 
Figure 12).

8.  Carefully  move  fireplace,  with  vent  as

-

sembly attached, toward wall and insert 
vent pipe into horizontal termination. Pipe 
overlap should be a minimum of 1 

1

/

4

" (see 

Figure 13, page 11).

9. 

Combustible Exterior Wall Only:

 Slide 

wall firestop against interior wall surface 
and attach with screws provided. See Fig

-

ure 13, page 11, for horizontal termination 
details.

10. Place fireplace into position and shim with 

noncombustible material if needed. Nail or 
screw side flanges to framing to secure 
unit in place. 

IMPORTANT:

 Make sure fire

-

place is level before securing. If fireplace 
is not level it will not work properly.

Figure 10 - Installing Horizontal Vent Cap 

(Noncombustible Exterior) 

Wood Screw

Vent Cap

Figure 11 - Installing Siding Standoff 

(Combustible Exterior Wall)

Cut Siding Away to 
Fit Standoff

Wood 
Screw

Screws

Standoff

Vent 
Cap

Apply Mastic to 
All Four Sides

Vent Cap
(Horizontal 
Termination)

Interior Wall 
Surface

Wall 
Firestop

Horizontal 
Vent Pipe

Figure 12 - Connecting Vent Cap with 

Horizontal Vent Pipe

Screw

Apply Mastic to 
All Four Sides

Summary of Contents for CHDV32NR

Page 1: ...uids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelyca...

Page 2: ...ce must be performed by a qualified installer service agency or the gas supplier WARNING This product contains and or generates chemicals known to the State of California to cause cancer or birthdefec...

Page 3: ...an be dangerous Do not modify this fireplace under any circum stances Any parts removed for servicingmustbereplacedprior to operating fireplace WARNING This appliance is only for use with the type of...

Page 4: ...ational Electrical Code ANSI NFPA 70 9 Do not use fireplace if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 10 Do not...

Page 5: ...gh temperatures do not locate this fireplace in high traffic areas windy or drafty areas or near furniture or draperies Proper clearances must be maintained If your fireplace is to be installed direct...

Page 6: ...terials 0 clear ance to combustible materials are for framing purpose only NOTICE This fireplace is in tended for use as supplemental heat Use this fireplace along with your primary heating sys tem Do...

Page 7: ...0 000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canad...

Page 8: ...pipe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning ap...

Page 9: ...ht into match ing slots on male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Hori...

Page 10: ...ews provided see Figure 11 Siding standoff must sit flush against exterior fascia material 7 Combustible Exterior Wall Only Slide wall firestop over vent pipe before con necting horizontal run to vent...

Page 11: ...ion cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could cause a fire Operation of improperly...

Page 12: ...1 2 min None 30 max 51 1 2 min 1 ft 48 max 63 1 2 min 2 ft 60 max 75 1 2 min 3 ft 84 max 87 1 2 min 4 ft 20 max Ground Floor Corner Venting Not to Exceed H Limits SNORKEL TERMINATION INSTALLATION Rec...

Page 13: ...iguration for Venting Using Two 90 Elbows 45 Elbow HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal sys tem...

Page 14: ...ould be framed to 10 x 10 inside dimensions as shown in Figure 9 on page 9 using framing lumber the same size as the ceiling joists If the area above the ceiling is an insulated ceiling or attic space...

Page 15: ...H2 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Figure 21 Vertical Venting Configuration Using Two 90 Elbows with Two Horizontal Runs Vertical Round High Wind Termination Shown Note In...

Page 16: ...wn 45 Elbow High Altitude Installation Your FMI PRODUCTS LLC direct vent fire place has been tested and approved for eleva tions from 0 2 000 feet USA and elevations from 0 4 500 feet Canada When inst...

Page 17: ...ipe Wall Firestop Storm Collar Roof Flashing 0 12 6 12 26 Screws VKC 47 Corner Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Termination 6 Pipe 90 Elbow 18 Screws...

Page 18: ...The blower will fit inside backopeningandbeheldinpositionagainst back wall by magnets see Figure 25 4 Be certain that all wire terminals are securely attached to terminals on blower motor and screw r...

Page 19: ...o sense temperature and properly operate Blower will be held in position against back wall by magnets incorporated onto blower housing see Figure 28 4 Be certain that all wire terminals are securely a...

Page 20: ...have the items listed below external regulator supplied by installer piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint...

Page 21: ...ine as shown in Figure 31 Locate sediment trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap drip leg where trapped ma...

Page 22: ...ce or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 3 Check all joints from propane LP supply tank or gas meter to equipment shutoff valve see F...

Page 23: ...als are in positions on unit as pictured in Figure 36 If wires are not connected as shown switch will not work 2 Route 25 ft wire through openings pro vided on sides of burner system to a con venient...

Page 24: ...ire assembly glass and frame must be replaced If glass is broken wear gloves and tape the remaining fragments onto the frame 1 Remove screen assembly by pushing the rod either left or right and then d...

Page 25: ...el 7 Install the right brick panel using the same method described 8 Replace deflector shield using screws removed in step 4 9 Install logs lava rock and ember material see Installing Logs Lava Rock a...

Page 26: ...and grate prongs see Figure 49 This will create glowing ember appear ance as flame touches ember material Do not block air slots by using too much ember material in one area It is not necessary to us...

Page 27: ...igure 50 5 Slide other end of adjusting plate shim in slot on mitered edge of side trim see Figure 50 Side Trim Mitered Edge Shim Adjusting Plate Set Screws Top Trim Slot Slot Figure 50 Assembling Tri...

Page 28: ...pped with an igni tion device which automatically lights the pilot Do not try to light by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because...

Page 29: ...ssory Gas Control Knob in ON Position Variable Control Knob Figure 54 On Off Hand Held Remote Control Unit HRC100 Control Button Indicator Light IMPORTANT Do not leave the selector switch in the REMOT...

Page 30: ...et wall thermostat to desired temperature This thermostat has been electronically cali brated at the factory and requires no adjust ment or leveling Upon installation the thermostat must be al lowed t...

Page 31: ...Figure 57 Typical Flame Pattern Thermocouple Thermopile 1 8 Pilot Burner Piezo Ignitor Figure 56 Pilot Assembly 3 8 to 1 2 Cleaning and Maintenance WARNING Turn off fireplace and let cool before clea...

Page 32: ...to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dirt or lint Cleaning and Maintenance Continued logs If you remove logs for cleaning refer to Insta...

Page 33: ...uipment shutoff valve closed 2 Gas control knob not in PILOT position 3 Gas control knob not pressed in while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP mod...

Page 34: ...d pressure is too low 2 Burner porting or orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective 1 Residues from manufac turing processes and logs curing REM...

Page 35: ...installa tion REMEDY 1 Turn gas control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP or natural gas compan...

Page 36: ...above 2 Control valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or exces sive blocka...

Page 37: ...and serial numbers of your heater ready You can also visit our web site at www fmiproducts com Specifications CHDV32NR Rating 12 000 18 000 Btu Hr Gas Type Natural Ignition Piezo Manifold Pressure 3 5...

Page 38: ...nted on off switch gwms2 Allows burner system to be turned on and off with a wall switch Accessories Continued Thermostatically controlled blower kit BKT Provides better heat distribution Blower turns...

Page 39: ...www fmiproducts com 111986 01G 39 Parts Model CHDV32NR 6 7 21 18 19 10 13 2 12 20 8 22 2 22 6 22 4 22 5 22 3 22 1 1 14 9 11 17 15 4 5 16 3...

Page 40: ...108897 01 Rear Refractory Brick Panel Not Included 1 12 109082 03 Heat Shield 1 13 108901 01 Right Refractory Brick Panel Not Included 1 14 108901 02 Left Refractory Brick Panel Not Included 1 15 1141...

Page 41: ...www fmiproducts com 111986 01G 41 Parts BURNER ASSEMBLY Model CHDV32NR 3 2 1 13 14 18 15 16 4 5 7 8 6 9 12 10 11 17 19...

Page 42: ...m 1 5 14389 Millivolt Valve Natural Gas 1 6 14492 Piezo Ignitor 1 7 14500 Brass Fitting 2 8 14253 Flexible Connector 1 9 14511 Ignitor Bracket 1 10 14528 Brass Elbow Fitting 1 11 104506 25 Orifice Nat...

Page 43: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____...

Page 44: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat...

Reviews: