background image

9

104332

OWNER’S MANUAL

Attaching Mounting Bracket To
Wall

Note:

 Wall anchors, mounting screws, and

spacers are in hardware package. The hard-
ware package is provided with heater.

Attaching to Wall Stud method

For attaching mounting bracket to wall studs

1.

Drill holes at marked locations using
9/64" drill bit.

2.

Place mounting bracket onto wall. Line
up last hole on each end of bracket with
holes drilled in wall.

3.

Insert mounting screws through bracket
and into wall studs.

4.

Tighten screws until mounting bracket
is firmly fastened to wall studs.

Attaching to Wall Anchor Method

For attaching mounting bracket to hollow
walls (wall areas between studs) or solid
walls (concrete or masonry)

1.

Drill holes at marked locations using
5/16" drill bit. For solid walls (concrete
or masonry), drill at least 1" deep.

2.

Fold wall anchor as shown in Figure 9.

3.

Insert wall anchor (wings first) into
hole. Tap anchor flush to wall.

4.

For thin walls (1/2" or less), insert red
key into wall anchor. Push red key to
“pop” open anchor wings.

IMPORTANT:

 Do not hammer key!

For thick walls (over 1/2" thick) or solid
walls, do not pop open wings.

5.

Place mounting bracket onto wall. Line
up last hole on each end of bracket with
wall anchors.

6.

Insert mounting screws through bracket
and into wall anchors.

7.

Tighten screws until mounting bracket
is firmly fastened to wall.

Figure 9 - Folding Anchor

INSTALLATION

Continued

Figure 10 - Popping Open Anchor Wings
For Thin Walls

Stand-Out
Tab

Figure 11 - Mounting Heater Onto
Mounting Bracket

Figure 12 - Installing Bottom Mounting
Screws

Horizontal Slots

Mounting Bracket
(attached to wall)

Placing Heater On Mounting
Bracket

1.

Locate two horizontal slots on back
panel of heater.

2.

Place heater onto mounting bracket.
Slide horizontal slots onto stand-out
tabs on mounting bracket.

Installing Bottom Mounting
Screws

1.

Locate two bottom mounting holes.
These holes are near bottom on back
panel of heater (see Figure 11 ).

2.

Mark screw locations on wall.

3.

Remove heater from mounting bracket.

4.

If installing bottom mounting screws
into hollow or solid wall, install wall
anchors. Follow steps 1 through 4 un-
der Attaching To Wall Anchor Method.

If installing bottom mounting screw
into wall stud, drill holes at marked lo-
cations using 9/64" drill bit.

5.

Replace heater onto mounting bracket.

6.

Place spacers between bottom mount-
ing holes and wall anchor or drilled
hole.

7.

Hold spacer in place with one hand.
With other hand, insert mounting screw
through bottom mounting hole and
spacer. Place tip of screw in opening
of wall anchor or drilled hole.

8.

Tighten both screws until heater is
firmly secured to wall. Do not over
tighten.

Note:

 Do not replace front panel at this

time. Make gas connections and check
for leaks before replacing front panel
(see pages 10 and 11).

Continued

Summary of Contents for CGP20TB

Page 1: ...ence CGP20TB CGP20TLB CGP30TB CGP30TLB 20 000 Btu Hr Thermostat and 30 000 Btu Hr Thermostat Model Heaters WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury...

Page 2: ...can be dangerous 4 This heater shall not be installed in a bedroom or bathroom 5 This heater needs fresh outside air ven tilation to run properly This heater has an Oxygen Depletion Sensing ODS safety...

Page 3: ...shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sen...

Page 4: ...ing only iftherearedoorlesspassagewaysorventila tion grills between them PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code NFPA 54 ANS Z223 1 Sec tion5 3 AirforComb...

Page 5: ...include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used...

Page 6: ...igure 2 Ventilation Air from Inside Building WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in bot...

Page 7: ...N This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as...

Page 8: ...ng bracket to wall in one of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Removing Front Panel Of Heater 1 Remove two screws near bottom cor ners of front panel 2 Liftstraightupongrill...

Page 9: ...l mounting bracket is firmly fastened to wall Figure 9 Folding Anchor INSTALLATION Continued Figure 10 Popping Open Anchor Wings For Thin Walls Stand Out Tab Figure 11 Mounting Heater Onto Mounting Br...

Page 10: ...un properly IMPORTANT Holdpressureregulatorwith wrench when connecting it to gas piping and or fittings CAUTION Never connect heater directly to the propane LP supply This heater requires an external...

Page 11: ...ppliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHATTODOIFYOUSMELLGAS Do not try to light any appliance Do not touch any elec...

Page 12: ...ol knob Note If pilot goes out repeat steps 3 through 7 This heater has a safety interlock system Wait one 1 minute before lighting pilot again 8 Turn control knob counterclockwise C clockwise to desi...

Page 13: ...an WARNING Turn off heater and let cool before cleaning CAUTION You must keep control areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have h...

Page 14: ...d REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Tighten nut holding piezo ignitor to heater cabin...

Page 15: ...ound clean burner see Cleaning and Maintenance page 13 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Oper...

Page 16: ...se just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Moisture conde...

Page 17: ...may be low When Gas Quality Is Bad pilot will not stay lit burner will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your l...

Page 18: ...ted on the back page of this manual FLOOR MOUNTING STAND 20 000 Btu Hr Models CGP20TLB GA4500L Ivory CGP20TB GA4500 Champagne 30 000 Btu Hr Models CGP30TLB GA4510L Ivory CGP30TB GA4510 Champagne For l...

Page 19: ...ww nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542 732 870 8809 1...

Page 20: ...20 104332 BLUE FLAME PROPANE LP HEATER 11 1 11 2 CGP20TB CGP20TLB CGP30TB CGP30TLB ILLUSTRATED PARTS BREAKDOWN 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 16 18 19 20 21 22 15 23 24 17 7...

Page 21: ...Cable 1 10 098249 01 098249 01 Nut M5 2 11 103594 04 103594 04 Pilot ODS 1 11 1 098514 01 098514 01 Thermocouple 1 11 2 106842 01 106842 01 Ignitor Electrode 1 12 103446 01 103447 01 Burner 1 13 0993...

Page 22: ...the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper m...

Reviews: