9
102651
INSTALLING
Continued
Figure 4 - Minimum Clearance to Wall and Ceiling
Continued
Carefully follow the instructions below. This will ensure safe installation into a
masonry or U.L. listed manufactured fireplace.
Minimum Wall and Ceiling Clearances (see Figure 4)
A. Clearances from the side of the fireplace opening to any combustible wall
should not be less than 16 inches.
B. Clearances from the top of the fireplace opening to the ceiling should not be
less than 42 inches.
42"
16"
INSTALLATION AND CLEARANCES (Vent-Free Operation Only)
WARNING
Maintain the minimum clearances. If you can, provide greater
clearances from floor, ceiling, and adjoining wall.
LOG SIZING REQUIREMENTS
Log
Minimum Firebox Size
Size
Height
Depth
Front Width
18"
17"
14"
20"
24"
17"
14"
26"
30"
17"
14"
32"
MINIMUM FIREPLACE CLEARANCE
TO COMBUSTIBLE MATERIALS
Log Size
Side Wall
Ceiling
18", 24", 30"
16"
42"