21
102651
OPERATING
HEATER
Thermostat-
Controlled Models
Continued
Figure 21 - Pilot
Continued
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B” in the safety information on page 20. If
you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position. Press in
control knob for five (5) seconds (see page 20).
Note:
You may be running this heater for the first time after hooking up to gas
supply. If so, the control knob may need to be pressed in for 30 seconds or less.
This will allow air to bleed from the gas system.
6. With control knob pressed in, press and release ignitor button. This will light
pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service person or gas supplier
for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see
Manual Lighting Procedure
, page 22.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob.
Note:
If pilot goes out, repeat steps 3 through 7. This heater has a safety
interlock system. Wait one (1) minute for system to reset before lighting pilot
again.
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise
to the PILOT position.
Thermocouple
Ignitor Electrode
Pilot Burner
• If control knob does not pop out when released, contact a qualified service
person or gas supplier for repairs.
8. Turn control knob counterclockwise
to desired heating level. The
burners should light. Set control knob to any heat level between HI and LO.
Summary of Contents for CG2618PVA