Comfort Glow CF26PR Owner'S Operation And Installation Manual Download Page 30

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004

www.desatech.com

INTERNATIONAL

105442-01
REV. A
06/99

LIMITED WARRANTY

VENT-FREE PROPANE/LP GAS HEARTH

 FIREPLACE

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first
purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this fireplace to
proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be
obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure
to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a qualified installer in accordance with
all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged
as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor,
transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT;
THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION
OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA
INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNA-
TIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
We make no other warranty, expressed or implied.

WARRANTY INFORMATION

NOT A UPC

105442 01

Summary of Contents for CF26PR

Page 1: ...any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor sphone Followthegassupplier s instructions If you cannot reac...

Page 2: ...ock and debris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 Thi...

Page 3: ...ludes one hardware packet 4 Checkfireplaceforanyshippingdamage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with a...

Page 4: ...rlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven t...

Page 5: ...Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ Btu Hr maximum the sp...

Page 6: ...N Continued Figure 2 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ven...

Page 7: ...t top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is beneficial installing firepla...

Page 8: ...gas line to fireplace gas regulator See Connecting Fireplace to Gas Supply page 13 6 If the optional blower has been installed connect blower to electrical source Option one Route blower electrical co...

Page 9: ...achmenttowall 9 Slide mantel around fireplace Be care ful not to damage wall or mantel Note All vertical measurements are from top of fireplace opening to bottom of mantel shelf 10 Adjust assembly to...

Page 10: ...ss through lower opening to the left of the blower control shield see Figure 16 8 Insert the 4 wire harness into one of the round holes in the rear of the blower control shield and through the rectan...

Page 11: ...pplied will not be used in built in installations Pop intheplasticsnapbushingfoundinhard warekitintotheholeleftbysupplycord strain relief 4 A licensed electrician must follow the wiring diagram in Fig...

Page 12: ...n Figure 20 Pointing the vent down protects it from freezing rain or sleet Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hoo...

Page 13: ...ssible Manual Shut Off Valve Flexible Gas Line from Fireplace Gas Valve Provided with Fireplace To Fireplace Gas Valve 2 Apply pipe joint sealant lightly to male threads of gas connector attached to f...

Page 14: ...WARNING Neveruseanopen flame to check for a leak Apply a mixture of liquid soap and water toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure external regulator has been...

Page 15: ...ling Receiver 1 Disconnect switch wires from the con trol valve 2 Remove screws and nuts 3 Remove switch plate see Figure 28 Discard after removing 4 Install remote receiver unit onto gas log heater b...

Page 16: ...Volt Battery Not Included in Hand Held Remote Control Unit 1 Remove battery cover on back of re mote control unit 2 Attach terminal wires to the battery Place battery into the battery housing 3 Replac...

Page 17: ...hand held remote ON button was on when selector switch was last turned off You can now turn the burner on and off with the hand held remote control unit IMPORTANT Do not leave the selector switch in t...

Page 18: ...ough 22 Pilot Burner Thermocouple INSPECTING BURNERS BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance These holes may become blocked with d...

Page 19: ...lean burning flame Keep these holesclearofdust dirt andlint Cleanthese air inlet holes prior to each heating season Blocked air holes will create soot We rec ommend that you clean the unit every 2 500...

Page 20: ...EMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base pa...

Page 21: ...lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Obse...

Page 22: ...noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 Th...

Page 23: ...t Cans Unlimited Inc P O Box 645 Taylor SC 29687 0013 All States 803 879 3009 1 800 845 5301 Parts Department Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Pa...

Page 24: ...VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PR ILLUSTRATED PARTS BREAKDOWN CF26PR O F F P I L O T O N H I L O O F F P I L O T O N H I L O 16 15 19 8 19 20 21 17 18 14 13 23 10 12 22 13 4 7 6 9 5 11...

Page 25: ...1 7 099056 21 Burner Orifice Injector 1 8 099998 01 Switch 1 9 102980 01 Burner 1 10 099387 13 Pilot Tube 1 11 103781 02 Gas Control Valve 1 12 103345 02 Lower Bracket 1 13 M11084 38 Screw 8 x 38 7 1...

Page 26: ...26 105442 VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PR ILLUSTRATED PARTS BREAKDOWN CF26PR 5 8 15 17 13 14 11 2 11 1 21 19 4 12 16 10 6 5 9 1 2 18 7 20 2 20 3 20 1 18 18 16 22 3 18 16 3 22...

Page 27: ...11 Rivets 8 14 105262 01CK Louvered Door 1 15 105261 01CK Firebox Floor 1 16 098304 01 Screw 10 x 3 8 21 17 105256 01CK Bayfront Bottom Panel 1 18 M11084 26 Hex Head Screws 10 x 38 26 19 105513 01CV...

Page 28: ...te assembly instructions in cluded Three sided brass trim kit included MANUAL SHUTOFF VALVE GA5010 Manual shutoff valve with 1 8 NPT tap THERMOSTATICALLY CONTROLLED BLOWER KIT GA3450T Provides better...

Page 29: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 30: ...ance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of th...

Reviews: