Comfort Glow CF26PR Owner'S Operation And Installation Manual Download Page 15

15

105442

OWNER’S MANUAL

 WARNING: Failure to position

the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.

INSTALLING LOGS

It is very important to install the logs exactly
as instructed. Do not modify logs. Only use
logs supplied with heater.

Place one-piece log set on grate to fit as
illustrated in Figure 26. Make sure back
section of log set is seated into “U”-shaped
cutout in center of chassis (see Figure 26).

IMPORTANT:

 Make sure log does not cover

any burner ports (see Figure 27).

 CAUTION: After installation

and periodically thereafter, check
to ensure that no flame comes in
contact with any log. With the
heater set to High, check to see if
flames contact any log. If so, re-
position logs according to the
log installation instructions in this
manual. Flames contacting logs
will create soot.

Figure 26 - Installing One-Piece Log Set

AUT

O

OFF
ON

One Piece Log Set

Burner

"U"-shaped
Cutout in
Chassis

Chassis

Figure 27 - Installing One-Piece Log set
(Top View)

One Piece Log Set

Burner
Ports

OPTIONAL WIRELESS HAND-
HELD REMOTE CONTROL
ACCESSORIES

(CGHRC & CGHRCT Series)

Installing Receiver

1.

Disconnect switch wires from the con-
trol valve.

2.

Remove screws and nuts.

3.

Remove switch plate (see Figure 28).
Discard after removing.

4.

Install remote receiver unit onto gas log
heater base using clips (2) and insulat-
ing washers provided.

5.

Push clips firmly into place (see Fig-
ure 29).

6.

Connect wires as shown in Figure 30.

INSTALLATION

Continued

Figure 28 - Switch Plate and Wiring
Harness (Switch Plate and Orientation
May Vary Depending On Model)

Front

Back

Wires

Nut

Nut

Screw

Front

Front

Back

Figure 29 - Installing Remote Receiver

Insulating Washers

Remote
Receiver

Mounting
Clips

Back

Back

INSTALLING WIRELESS
REMOTE CONTROL
ACCESSORY

Two 9-volt alkaline batteries (not included)
are required to operate this heater with the
wireless hand held remote control set. One
battery must be installed in the receiver and
one in the hand-held remote control unit.

Note:

 Only use alkaline batteries.

Installing 9-Volt Battery in
Receiver

1.

Locate back of receiver under front
burner of heater.

2.

Locate the battery clip mounted on the
back of the receiver.

3.

Slide a 9-volt battery through the clip.

4.

Attach the terminal wires to the battery.

Figure 31 - Installing Receiver on the
Back of the Base

Figure 30 - Connecting Wires

Red Wire From
Receiver

Valve

White Wire
From Receiver

Front

Battery
Clip

9-Volt
Battery

Receiver

Terminal
Wires

Continued

Summary of Contents for CF26PR

Page 1: ...any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor sphone Followthegassupplier s instructions If you cannot reac...

Page 2: ...ock and debris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 Thi...

Page 3: ...ludes one hardware packet 4 Checkfireplaceforanyshippingdamage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with a...

Page 4: ...rlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven t...

Page 5: ...Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ Btu Hr maximum the sp...

Page 6: ...N Continued Figure 2 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ven...

Page 7: ...t top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is beneficial installing firepla...

Page 8: ...gas line to fireplace gas regulator See Connecting Fireplace to Gas Supply page 13 6 If the optional blower has been installed connect blower to electrical source Option one Route blower electrical co...

Page 9: ...achmenttowall 9 Slide mantel around fireplace Be care ful not to damage wall or mantel Note All vertical measurements are from top of fireplace opening to bottom of mantel shelf 10 Adjust assembly to...

Page 10: ...ss through lower opening to the left of the blower control shield see Figure 16 8 Insert the 4 wire harness into one of the round holes in the rear of the blower control shield and through the rectan...

Page 11: ...pplied will not be used in built in installations Pop intheplasticsnapbushingfoundinhard warekitintotheholeleftbysupplycord strain relief 4 A licensed electrician must follow the wiring diagram in Fig...

Page 12: ...n Figure 20 Pointing the vent down protects it from freezing rain or sleet Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hoo...

Page 13: ...ssible Manual Shut Off Valve Flexible Gas Line from Fireplace Gas Valve Provided with Fireplace To Fireplace Gas Valve 2 Apply pipe joint sealant lightly to male threads of gas connector attached to f...

Page 14: ...WARNING Neveruseanopen flame to check for a leak Apply a mixture of liquid soap and water toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure external regulator has been...

Page 15: ...ling Receiver 1 Disconnect switch wires from the con trol valve 2 Remove screws and nuts 3 Remove switch plate see Figure 28 Discard after removing 4 Install remote receiver unit onto gas log heater b...

Page 16: ...Volt Battery Not Included in Hand Held Remote Control Unit 1 Remove battery cover on back of re mote control unit 2 Attach terminal wires to the battery Place battery into the battery housing 3 Replac...

Page 17: ...hand held remote ON button was on when selector switch was last turned off You can now turn the burner on and off with the hand held remote control unit IMPORTANT Do not leave the selector switch in t...

Page 18: ...ough 22 Pilot Burner Thermocouple INSPECTING BURNERS BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance These holes may become blocked with d...

Page 19: ...lean burning flame Keep these holesclearofdust dirt andlint Cleanthese air inlet holes prior to each heating season Blocked air holes will create soot We rec ommend that you clean the unit every 2 500...

Page 20: ...EMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base pa...

Page 21: ...lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Obse...

Page 22: ...noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 Th...

Page 23: ...t Cans Unlimited Inc P O Box 645 Taylor SC 29687 0013 All States 803 879 3009 1 800 845 5301 Parts Department Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Pa...

Page 24: ...VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PR ILLUSTRATED PARTS BREAKDOWN CF26PR O F F P I L O T O N H I L O O F F P I L O T O N H I L O 16 15 19 8 19 20 21 17 18 14 13 23 10 12 22 13 4 7 6 9 5 11...

Page 25: ...1 7 099056 21 Burner Orifice Injector 1 8 099998 01 Switch 1 9 102980 01 Burner 1 10 099387 13 Pilot Tube 1 11 103781 02 Gas Control Valve 1 12 103345 02 Lower Bracket 1 13 M11084 38 Screw 8 x 38 7 1...

Page 26: ...26 105442 VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PR ILLUSTRATED PARTS BREAKDOWN CF26PR 5 8 15 17 13 14 11 2 11 1 21 19 4 12 16 10 6 5 9 1 2 18 7 20 2 20 3 20 1 18 18 16 22 3 18 16 3 22...

Page 27: ...11 Rivets 8 14 105262 01CK Louvered Door 1 15 105261 01CK Firebox Floor 1 16 098304 01 Screw 10 x 3 8 21 17 105256 01CK Bayfront Bottom Panel 1 18 M11084 26 Hex Head Screws 10 x 38 26 19 105513 01CV...