GAS SHUTOFF

VALVE OPERATION

Flame Adjustment

Adjust the flame ON/OFF by turning gas shut

-

off valve counterclockwise 

 to open or 

clockwise 

 to close, as necessary.

Shutting Off Appliance

Turn  gas  shutoff  valve  clockwise 

  to 

OFF position.

CURING 

LOGS

During the 2-3 hour appliance break-in period, 
you may detect an odor from the appliance 
as  various  paints  and  compounds  used  in 
manufacturing of this log set cure. This is a 
normal  and  temporary  situation  that  is  not 
cause for alarm. However, you may want to 
provide extra ventilation to the room during 
this time.
To ensure proper curing of the logs:
•  Ignite  a  2"  flame  and  maintain  it  for  1 

hour.

•  Burn logs in consecutive 1 hour periods 

raising the flame an additional 2" to full 
flame height for a total of three hours.

OPERATING

INSTRUCTIONS

FOR GA9050A-1

Note: Operation instructions for GA9050A-1 
Remote Ready Valve/Pilot Kit will be included 
with the kit.

1.  STOP!  Read  the  safety  information, 

column 1.

2.  Make sure equipment shutoff valve is fully 

open.

3.  Press in and turn control knob clockwise 

 to the OFF position.

4.  Wait five (5) minutes to clear out any gas. 

Then  smell  for  gas  around  log  set  and 
near floor. If you smell gas, STOP! Refer 

to  the 

National  Fuel  Gas  Codes, ANSI 

Z233.1/NFPA 54, Air for Combustion and 
Ventilation

. If you don’t smell gas, go to 

the next step.

5.  Turn  control  knob  counterclockwise 

 to the PILOT position and press 

in. Keep control knob pressed in for five 
(5) seconds.

OPERATION

FOR YOUR SAFETY

READ BEFORE LIGHTING

 WARNING: Keep flue open 

when operating unit.

 WARNING: If you do not fol-

low  these  instructions  exactly, 

a  fire  or  explosion  may  result 

causing property damage, per

-

sonal injury or loss of life.

BEFORE LIGHTING smell all around the ap

-

pliance area for gas. Be sure to smell next 
to the floor because some gas is heavier 
than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electric switch; do not 

use any phone in your building.

•  Immediately call your gas supplier from 

a  neighbor’s  phone.  Follow  the  gas 
supplier’s instructions.

•  If  you  cannot  reach  your  gas  supplier, 

call the fire department.

LIGHTING 

 INSTRUCTIONS

1.  STOP!  Read  the  safety  information, 

above.

2.  Turn gas shutoff valve to OFF.
3.  Wait five (5) minutes to clear out any gas. 

If you then smell gas STOP! Follow the 
safety  information,  above.  If  you  don't 
smell gas, go on to the next step.

4.  Light  a  match  and  lay  it  on  top  of  pan 

material about 2" from end of supply side 

of pan

5.  Slowly  turn  gas  shutoff  valve  ON  until 

burner  ignites.  If  burner  doesn’t  ignite 
within  10  seconds  with  match  burning, 
turn shutoff valve OFF and repeat steps 
1 through 4 again.

Summary of Contents for and CVDR30

Page 1: ...as supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Ret...

Page 2: ...made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts WARNING Thisproductcon tainsand orgenerateschemicals known to the State of California to cause cancer or birth defects or...

Page 3: ...ng fire place the chimney flue and firebox must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimneyfluefordamage Ifda...

Page 4: ...ontrol system if using GA9050A 1 or GA9150A and any gas control which has been under water 10 To help prevent breakage new logs must be broken in see Curing Logs page 14 11 Turn log set off and let co...

Page 5: ...urces to light This system may be connected to a wall switch or hand held wireless remote control See Accessories page 26 Remote Control Accessories There is an optional hand held ON OFF re mote contr...

Page 6: ...6 27 18 18 Model BFLT18 Front Width Back Width Depth Height 28 16 15 1 2 18 Model BFLT24 Front Width Back Width Depth Height 30 22 15 1 2 18 installation Continued NOTICE Installation service andrepai...

Page 7: ...st be installed or the damper blade must be cut or removed INSTALLATION Continued Damper Clamp Damper Clamp Damper Manufactured Fireplace Masonry Fireplace Figure 3 Attaching Damper Clamp Damper CONNE...

Page 8: ...check for a leak Applyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correct all leaks at once Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PS...

Page 9: ...t to the ac tion of propane LP gas on larger end of fitting screw burner inlet fitting through hole and into burner manifold see Fig ure 6 Tighten using a wrench If using propane LP gas see Propane LP...

Page 10: ...tural Gas Installation 1 Thread gas control valve onto burner inlet fitting see Figure 8 Use thread sealant on male threads of burner inlet fitting Hold burner inlet fitting with a wrench to prevent o...

Page 11: ...upplied with orifice installed for a 24 log set If you have an 18 or 30 set you must change this orifice also See Figure 1 page 5 for product identification Burner Inlet Fitting 1 Remove burner inlet...

Page 12: ...ystem is leak free 4 When burner is tested and leak free observe individual tongues of flame on burner Note Burner design includes more ports on the outside of the bar Make sure that all ports are cle...

Page 13: ...and Back Logs Number and style may vary 5 Place smaller top logs onto bottom logs see Figure 17 Leave as much open space between logs as possible to mini mize flame impingement and sooting Note Logs m...

Page 14: ...Codes ANSI Z233 1 NFPA 54 Air for Combustion and Ventilation If you don t smell gas go to the next step 5 Turn control knob counterclockwise to the PILOT position and press in Keep control knob press...

Page 15: ...7 page 14 8 Turn control knob counterclockwise to the ON position Burner should light If burner does not light call a quali fied service person 9 To leave pilot lit and shut off burners only turn cont...

Page 16: ...ned and checked 3 Separate the logs to allow more flame passage 4 Remove any foreign items from the flame pattern and or check for proper orifice sizing 5 Preheat flue in very cold weather 1 Relieve a...

Page 17: ...shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repeat ignit ing operation until air is removed 5 Adjust pilot...

Page 18: ...ning vapors from paint hair spray glues cleaners chemi cals new carpet etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page...

Page 19: ...FMI PRODUCTS LLC at 1 866 328 4537 When calling please have your model and serial numbers of your heater ready You can also visit our web site at www fmiproducts com Replacement Parts Note Use only or...

Page 20: ...w fmiproducts com 901265 U 20 Parts Models CVSR18 CVSR24 CPVSR18 and CPVSR24 3 1 8 6 4 2 10 11 12 13 14 15 16 23 17 22 21 20 19 18 7 5 9 9 Oxford Round Oak Logs Amherst Round Oak Logs CPVSR Models Onl...

Page 21: ...2 1 901243 02 Log Grate 1 2 1 901246 01 Log Grate 5 8 1 901246 02 Log Grate 5 8 1 11 901459 01 Bottom Front Log CPR 18 1 901459 01 Bottom Front Log CPR 24 1 12 901458 01 Bottom Rear Log CR 16 1 90145...

Page 22: ...www fmiproducts com 901265 U 22 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14a 14a 15b 16b 17f 17e 17a 15d 15f 14b 15c 15a 15e Berkshire Oak Log Set Coventry Oa PARTS Models CVDR18 CVDR24 and cvdr30...

Page 23: ...sembly 1 8 101628 01 Gas Line 10 Flex 1 9 901431 01 Grate Steps 2 10 901246 01 Log Grate 1 901246 02 Log Grate 1 901246 03 Log Grate 1 11 901681 01 Burner Strap 1 12 901078 01 Nut 8 32 1 13 901076 01...

Page 24: ...www fmiproducts com 901265 U 24 3 10 1 8 9 4 2 7 15 13 6 5 14 14 22 20 16 17 18 19 21 12 11 Mendocino Oak Log Set PARTS Models BFLT18 and BFLT24...

Page 25: ...er Pan 1 10 901076 01 Screw 8 32 x 3 8 1 11 901078 01 Nut 8 32 1 12 901681 01 Burner Strap 1 13 901242 01 Damper Clamp Std Assembly 1 14 901431 01 Grate Steps 2 15 901246 01 Log Grate 1 901246 02 Log...

Page 26: ...ol Ready on off safety Valve Pilot Kit GA9150A For all models Required for remote control operation Contains components for propane LP conversion Purchase these accessories from your local dealer If t...

Page 27: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 28: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Reviews: