Installation and Gas Connection

1.  Place burner pan assembly in center of 

fireplace  floor.  Make  sure  front  of  pan 
faces forward.

2.  Thread gas supply fitting to fireplace gas 

supply pipe. Use thread sealant.

3.  Install adapter fitting onto burner inlet fit

-

ting using thread sealant on male threads 
of burner inlet fitting (see Figure 7). Adjust 
to most convenient position.

4.  Install gas connector tube to gas supply 

fitting. Carefully shape tube to attach to 
adapter  fitting.  Be  careful  not  to  cause 
kinks in tube.

INSTALLATION

Continued

Figure 7 - Connecting Gas to Appliance

Adapter 

Fitting

Gas 

Connector 

Tube

Burner Pan 

Assembly 

(Facing Front 
of Fireplace)

OPTIONAL GA9050A-1 ON/OFF SAFETY 
VALVE/PILOT KIT ASSEMBLY

For additional convenience and safety, or for 
propane/LP conversion, an optional ON/OFF 
safety valve/pilot kit is available. See 

Acces-

sories

, page 26.

 WARNING: You must use a 

ON/OFF safety valve/pilot kit for 

propane/LP conversion.

Natural Gas Installation

1.  Thread gas control valve onto burner inlet 

fitting (see Figure 8). Use thread sealant 
on male threads of burner inlet fitting. Hold 
burner inlet fitting with a wrench to prevent 
overtightening connection to the burner. 
Make sure control rod is facing the front 
(see Figure 8).

2.  Attach pilot gas line to pilot outlet of gas 

control valve and tighten. Connect ther

-

mocouple  to  rear  of  gas  control  valve. 
See Figure 9. Do not overtighten. If us

-

ing propane/LP gas, see 

Changing Pilot 

Orifice

, page 12.

3.  Install inlet fitting into inlet opening of gas 

control valve (see Figure 10). Use thread 
sealant on male pipe threads.

4.  Place burner pan assembly in center of 

fireplace  floor.  Make  sure  front  of  pan 
faces forward.

5.  Thread gas supply fitting to fireplace gas 

supply  pipe. Adjust  to  most  convenient 
position.

Burner Inlet 
Fitting

Gas Control 
Valve

Burner Pan 

Assembly

Figure 8 - Installing Gas Control Valve

Control Rod

Figure 9 - Gas Control Valve with 

Thermocouple and Pilot

Figure 10 - Installing Inlet Fitting and 

Gas Connector Tube

Thermocouple 

and Line

Pilot and 
Line

Gas Control 
Valve

Gas Control 
Valve

Gas Inlet 
Fitting

Gas 

Connector 

Tube

Inlet 

Opening

Summary of Contents for and CVDR30

Page 1: ...as supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Ret...

Page 2: ...made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts WARNING Thisproductcon tainsand orgenerateschemicals known to the State of California to cause cancer or birth defects or...

Page 3: ...ng fire place the chimney flue and firebox must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimneyfluefordamage Ifda...

Page 4: ...ontrol system if using GA9050A 1 or GA9150A and any gas control which has been under water 10 To help prevent breakage new logs must be broken in see Curing Logs page 14 11 Turn log set off and let co...

Page 5: ...urces to light This system may be connected to a wall switch or hand held wireless remote control See Accessories page 26 Remote Control Accessories There is an optional hand held ON OFF re mote contr...

Page 6: ...6 27 18 18 Model BFLT18 Front Width Back Width Depth Height 28 16 15 1 2 18 Model BFLT24 Front Width Back Width Depth Height 30 22 15 1 2 18 installation Continued NOTICE Installation service andrepai...

Page 7: ...st be installed or the damper blade must be cut or removed INSTALLATION Continued Damper Clamp Damper Clamp Damper Manufactured Fireplace Masonry Fireplace Figure 3 Attaching Damper Clamp Damper CONNE...

Page 8: ...check for a leak Applyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correct all leaks at once Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PS...

Page 9: ...t to the ac tion of propane LP gas on larger end of fitting screw burner inlet fitting through hole and into burner manifold see Fig ure 6 Tighten using a wrench If using propane LP gas see Propane LP...

Page 10: ...tural Gas Installation 1 Thread gas control valve onto burner inlet fitting see Figure 8 Use thread sealant on male threads of burner inlet fitting Hold burner inlet fitting with a wrench to prevent o...

Page 11: ...upplied with orifice installed for a 24 log set If you have an 18 or 30 set you must change this orifice also See Figure 1 page 5 for product identification Burner Inlet Fitting 1 Remove burner inlet...

Page 12: ...ystem is leak free 4 When burner is tested and leak free observe individual tongues of flame on burner Note Burner design includes more ports on the outside of the bar Make sure that all ports are cle...

Page 13: ...and Back Logs Number and style may vary 5 Place smaller top logs onto bottom logs see Figure 17 Leave as much open space between logs as possible to mini mize flame impingement and sooting Note Logs m...

Page 14: ...Codes ANSI Z233 1 NFPA 54 Air for Combustion and Ventilation If you don t smell gas go to the next step 5 Turn control knob counterclockwise to the PILOT position and press in Keep control knob press...

Page 15: ...7 page 14 8 Turn control knob counterclockwise to the ON position Burner should light If burner does not light call a quali fied service person 9 To leave pilot lit and shut off burners only turn cont...

Page 16: ...ned and checked 3 Separate the logs to allow more flame passage 4 Remove any foreign items from the flame pattern and or check for proper orifice sizing 5 Preheat flue in very cold weather 1 Relieve a...

Page 17: ...shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repeat ignit ing operation until air is removed 5 Adjust pilot...

Page 18: ...ning vapors from paint hair spray glues cleaners chemi cals new carpet etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page...

Page 19: ...FMI PRODUCTS LLC at 1 866 328 4537 When calling please have your model and serial numbers of your heater ready You can also visit our web site at www fmiproducts com Replacement Parts Note Use only or...

Page 20: ...w fmiproducts com 901265 U 20 Parts Models CVSR18 CVSR24 CPVSR18 and CPVSR24 3 1 8 6 4 2 10 11 12 13 14 15 16 23 17 22 21 20 19 18 7 5 9 9 Oxford Round Oak Logs Amherst Round Oak Logs CPVSR Models Onl...

Page 21: ...2 1 901243 02 Log Grate 1 2 1 901246 01 Log Grate 5 8 1 901246 02 Log Grate 5 8 1 11 901459 01 Bottom Front Log CPR 18 1 901459 01 Bottom Front Log CPR 24 1 12 901458 01 Bottom Rear Log CR 16 1 90145...

Page 22: ...www fmiproducts com 901265 U 22 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14a 14a 15b 16b 17f 17e 17a 15d 15f 14b 15c 15a 15e Berkshire Oak Log Set Coventry Oa PARTS Models CVDR18 CVDR24 and cvdr30...

Page 23: ...sembly 1 8 101628 01 Gas Line 10 Flex 1 9 901431 01 Grate Steps 2 10 901246 01 Log Grate 1 901246 02 Log Grate 1 901246 03 Log Grate 1 11 901681 01 Burner Strap 1 12 901078 01 Nut 8 32 1 13 901076 01...

Page 24: ...www fmiproducts com 901265 U 24 3 10 1 8 9 4 2 7 15 13 6 5 14 14 22 20 16 17 18 19 21 12 11 Mendocino Oak Log Set PARTS Models BFLT18 and BFLT24...

Page 25: ...er Pan 1 10 901076 01 Screw 8 32 x 3 8 1 11 901078 01 Nut 8 32 1 12 901681 01 Burner Strap 1 13 901242 01 Damper Clamp Std Assembly 1 14 901431 01 Grate Steps 2 15 901246 01 Log Grate 1 901246 02 Log...

Page 26: ...ol Ready on off safety Valve Pilot Kit GA9150A For all models Required for remote control operation Contains components for propane LP conversion Purchase these accessories from your local dealer If t...

Page 27: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 28: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Reviews: