UNPACKING

1.  Remove all protective packaging from inside firebox. Carefully lift 

the firebox off the bottom corrugated tray.

2.  Carton should contain 2 deflective hoods and hardware packet in 

addition to firebox assembly. If items are missing, inform dealer 

where you bought firebox.

3.  Check firebox for any shipping damage. If firebox is damaged 

contact  IHP  at  Comfortflame.US.com  for  replacement  parts 

before returning to dealer.

NOTICE: The firebox identification label (including 

model number, serial number, clearances, etc.) is 

located underneath the heat shield. See Figure 19, 

page 14.

PRODUCT FEATURES

OPERATION

This firebox is designed for use with approved ANS Z21.11.2 decora-

tive type unvented room appliances. (Physical size limitations apply. 

Refer to minimum firebox requirements supplied with log appliance.) 

It requires no outside venting or chimney making installation easy 

and inexpensive. When used without the blower, the firebox requires 

no electricity making it ideal for emergency backup heat.

BLOWER ACCESSORY

This firebox will accept the GA3750A accessory. The variable blower 

allows you to select the fan speed you desire. The blower circulates 

heated air from the firebox into the room. Use of blower is optional.

BRICK LINER

This firebox features a concrete brick liner. As with all concrete liners, 

this liner may develop slight cracks when exposed to heat. These 

cracks will not affect the performance of the firebox or vent-free 

gas logs.

HEAT DEFLECTIVE HOOD

Two (2)  black painted steel hoods come standard with the unit, which 

must be installed for a safe operation.

Summary of Contents for Barkley Series

Page 1: ...stment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For assistance or additional information consult a...

Page 2: ...her flammable material on or near the appliance Never place any objects in the firebox or on logs Firebox front and screen becomes very hot when run ning firebox Keep children and adults away from hot...

Page 3: ...been under water due to the shock hazard that could result with the blower accessary if installed in place 13 Provide adequate clearances around air openings LOCAL CODES Install and use firebox with...

Page 4: ...cora tive type unvented room appliances Physical size limitations apply Refer to minimum firebox requirements supplied with log appliance It requires no outside venting or chimney making installation...

Page 5: ...es page 8 2 Everything needed to complete installation 3 This model CANNOT be installed in a bedroom or bathroom 4 Proper air for combustion and ventilation 5 Consider a location where heat output wou...

Page 6: ...e criteria above proceed to Determining Fresh Air Flow for Firebox Location Confined and Unconfined Space The National Fuel Gas Code ANS Z223 1 NFPA 54 defines a confined space as a space whose volume...

Page 7: ...provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see option 1 Figure 3 You can also remove door into adjoining room see...

Page 8: ...l lations Wall or framing material can be placed against any exterior surface on the rear sides or top of your firebox except where standoff spacers are integrally attached If standoff spacers are att...

Page 9: ...extending the full width and depth of the vent free firebox Figure 7 Minimum Mantel Clearances for Built In Installation Supplied Firebox Hoods Must Be Used at All Times Wire mesh Screen Firebox Top M...

Page 10: ...codes IMPORTANT See Connecting to Gas Supply in your log set owner s manual for details on gas hookup You may run the gas line from either side of the firebox see Figure 11 page 11 When you have deter...

Page 11: ...g the incoming gas line to the appliance regulator Secure all joints tightly with wrench but do not overtighten If a flexible gas line is used take care not to kink the connector WARNING All gas pipin...

Page 12: ...he receptacle with wires that are routed through the bushing provided see Figure 15 The recep tacle may be relocated to either side when necessary However the cover plate must be replaced over the unu...

Page 13: ...17 Optional Blower Wiring Diagram INCOMING 120V AC FUSE BOX OR BREAKER BLK BLK GRN GRN WHT WHT FIELD WIRE GND CONNECTORS NOT SUPPLIED VARIABLE SPEED CONTROL BLOWER RECEPTACLE ELECTRICAL RATING 120v 6...

Page 14: ...s to cool before handling IMPORTANT Turn off the gas supply at the external shutoff valve before servicing appliance Any safety screen or guard removed for servicing must be replaced prior to operatin...

Page 15: ...umbers of your fireplace ready You can also visit our web site at Comfortflame US com REPLACEMENT PARTS See Pages 16 to 17 for a complete replacement parts list Use only parts supplied from the manufa...

Page 16: ...ALOG NO MODEL F2564 BarkleySTXWS F2565 BarkleySTYWS These items are used on both sides of fireplace 8 14 16 16 16 7 1 7 2 2 16 11 12 6 6 6 15 15 15 15 13 18 5 15 15 15 15 6 6 15 15 4 15 15 15 15 15 15...

Page 17: ...tom Refractory Brick Liner 2 8 J7021 Side Refractory Retainer 4 9 J5691 Screen 4 10 J7104 Top Louver 2 11 J7105 Bottom Louver 2 12 J6835 Receptacle 15A DVP 1 J8145 Handy Box 1 7 8 Deep 1 J8146 Cover D...

Page 18: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___...

Page 19: ...will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the inst...

Page 20: ...s pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2015 IHP LLC P N 900564 00 Rev N C 09 2015 1508 Elm Hill Pike Suite...

Reviews: