VENT TERMINATION CLEARANCES

These instructions should be used as a guideline and do not supersede local codes in any way. Install venting 

according to local codes, these instructions, the current National Fuel Gas Code (ANSI z223.1/NFPA 54) in the USA or 

the current standards of CAN/CGA-b149.1 in Canada.

Vertical Vent Termination Clearances

Terminate multiple vent terminations according to the installation codes listed above and 

Figure 3

.

Figure 3 - Multiple Terminations

12”

(305 mm)

minimum

Terminate single vent caps relative to building components according to 

Table 6

.

Table 6 - Termination Heights for Vents above Flat or Sloped Roofs (NFPA 54 / ANSI Z223.1)—Gas Vent Rule

Roof Pitch

Termination Height *

12 

Roof pitch is X/12

2 ft

minimum

2 ft minimum

Lowest 

discharge

opening

H* 

*H = minimum height from roof to

lowest discharge opening of vent

Horizontal overhang

Vertical 

wall

Vent 

termination

Storm collar

Concentric 

vent pipe

Flashing 

1” (25.4 mm) minimum

clearance to combustibles

Flat to 6/12

1.0 ft (0.3 m)

6/12 to 7/12

1.25 ft (0.38 m)

7/12 to 8/12

1.5 ft (0.46 m)

8/12 to 9/12

2.0 ft (0.61 m)

9/12 to 10/12

2.5 ft (0.76 m)

10/12 to 11/12

3.25 ft (0.99 m)

11/12 to 12/12

4.0 ft (1.22 m)

12/12 to 14/12

5.0 ft (1.52 m)

14/12 to 16/12

6.0 ft (1.83 m)

16/12 to 18/12

7.0 ft (2.13 m)

18/12 to 20/12

7.5 ft (2.29 m)

20/12 to 21/12

8.0 ft (2.44 m)

Horizontal Vent Termination Clearances

The horizontal vent termination must have a minimum of 6” (152 mm) clearance to any overhead combustible 

projection of 2-1/2” (64 mm) or less (

Figure 4

). For projections exceeding 2-1/2” (64 mm) (

Figure 4

). For additional 

vent location restrictions refer to 

Table 7

.

All horizontal terminations may be located as close as 6” (152mm) to any (non-combustible and combustible) 

exterior sidewall. This distance may be decreased to 2” (51mm) for noncombustible exterior sidewalls with all 

approved terminations (

Table 7

).

Figure 4 - Horizontal Vent Termination Clearances

6”

(153 mm)

**Use 6-1/2” 

from center of 

termination for 

all horzontal 

terminations 

applicable

*

Combustible projection 

2-1/2” or less in length

Combustible projection 

greater than 2-1/2” in length

Ventilated 

soffit - 18” 

(457 mm)

Unventilated 

soffit - 12” 

(305 mm)

(152)

Termination kit

Termination kit**

6”

Summary of Contents for Aurora35DEN

Page 1: ...Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoiventêtreassuréspar un installateur ou un service d entretien qualifié ou par le fournisseur de gaz INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Installateur Laissez cette notice avec l appareil Consommateur Conservez cette notice pour c...

Page 2: ...RE EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques Una barrera diseñada para reducir el riesgo de quemaduras desde la mirilla v...

Page 3: ...s graves si se toca Mantenga a los niños alejados de la chimenea en funcionamiento Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros líquidos inflamables alejados de la chimenea Aún después de haber apagado el gas las superficies de la chimenea permanecen extremadamente ...

Page 4: ...on 10 Manufactured Home Requirements 12 Location 12 Vent Termination Clearances 13 Minimum Clearances to Combustibles 15 Wall Finishes Surrounds Mantels 16 Installation Preparation 16 Installation Sequence 17 Construct the Fireplace Framing 17 Route the Gas Supply Line to the Fireplace 19 Install the Vent System 25 Complete the Field Wiring 37 Connect the Gas Line 38 Verify Proper Fireplace Operat...

Page 5: ...ltes peuvent subir des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes...

Page 6: ...dangerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas supply to the appliance and have it serviced by a quali...

Page 7: ...r combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of the appliance These appliances are designed as supplemental heaters Therefore it is advisable to have an alternate primary heat source when installed in a d...

Page 8: ...cien qualifié L appareil devrait faire l objet d une inspection par un technicien professionnel avant d être utilisé et au moins une fois l an par la suite Des nettoyages plus fréquents peuvent être nécessaires si les tapis la literie et cetera produisent une quantité importante de pous sière Il est essentiel que les compartiments abritant les commandes les brûleurs et les conduits de circulation ...

Page 9: ...y Efficiency Efficiencies are based on Normal input operation Gas Pressure Table 3 Inlet Gas Supply Pressure Fuel Minimum Maximum Natural Gas 5 WC 1 25 kPa 10 5 WC 2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 4 Manifold Gas Supply Pressure Fuel Pressure Natural Gas 3 5 WC 0 87 kPa Propane 10 0 WC 2 49 kPa Test gauge connections are provided on the front of the millivolt and electronic ...

Page 10: ...territorial Authorities Having Jurisdiction and in accordance with the requirements of the CAN CGA B149 1 or CAN CGA B149 2 installation codes Commonwealth of Massachusetts requirements These appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met Install this appliance in accordance with Massachusetts Rules and Regulations 248 C M...

Page 11: ... in the cavity surrounding the fireplace If the fireplace is being installed on a cement slab in cold climates a sheet of plywood or other raised platform can be placed underneath to prevent conduction of cold transferring to the fireplace and into the room It also helps to seal inside surfaces and tape for maximum air tightness and caulk firestops ...

Page 12: ... conditioning ducting These direct vent fireplaces are uniquely suited for installations requiring a utility shelf positioned directly above the fireplace Utility shelves like these are commonly used for locating television sets and decorative plants Be aware that this is a heat producing fireplace Objects placed above the unit are exposed to elevated temperatures Do not insulate the space between...

Page 13: ...4 mm minimum clearance to combustibles Flat to 6 12 1 0 ft 0 3 m 6 12 to 7 12 1 25 ft 0 38 m 7 12 to 8 12 1 5 ft 0 46 m 8 12 to 9 12 2 0 ft 0 61 m 9 12 to 10 12 2 5 ft 0 76 m 10 12 to 11 12 3 25 ft 0 99 m 11 12 to 12 12 4 0 ft 1 22 m 12 12 to 14 12 5 0 ft 1 52 m 14 12 to 16 12 6 0 ft 1 83 m 16 12 to 18 12 7 0 ft 2 13 m 18 12 to 20 12 7 5 ft 2 29 m 20 12 to 21 12 8 0 ft 2 44 m Horizontal Vent Termi...

Page 14: ...to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly I Clearance to service regulator vent outlet 36 910 mm 36 910 mm J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other fireplace 6 150 mm for fir...

Page 15: ...materials such as carpeting vinyl tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Hearth Extension A hearth extension is not required with this fireplace If a hearth extension is used do not block the lower control compartment door Any hearth extension used is for appearance on...

Page 16: ... encroach the area defined by the fireplace front face black sheet metal Never allow combustible materials to be positioned in front of or overlapping the fireplace face Figure 39 Page 44 Non combustible materials such as surrounds and other fireplace trim may be installed on the fireplace face but they must not cover any portion of the removable glass panel or control compartment Vertical install...

Page 17: ...per Fireplace Operation Page 39 Finishing 14 Optional Install the Firebox Liners Page 54 15 Traditional Fireplaces Install the Logs Volcanic Stone and Glowing Embers Page 55 16 Contemporary Fireplaces Install Glass Media Page 54 17 Install the Glass Door Page 58 18 Adjust the Air Shutter to Ensure Proper Flame Appearance Page 42 19 Install the Hood Page 44 20 Reinstall the Included Barrier Page 44...

Page 18: ...ications do NOT apply for flexible venting When using flexible venting refer to the kit requirements for framing specifications Vent Framing Top Vent with One 90 Elbow NOTE Dimension D is the required framing depth when the finish material drywall thickness is 1 2 13mm Inches millimeters Framing construction to be 2 x 4 or larger B C D A 1 2 A 5 1 8 130 7 178 12 1 8 308 10 1 2 267 E Table 11 Firep...

Page 19: ...ing of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code NFPA 54 latest edition USA or CAN CGA B149 1 latest edition Canada The gas supply line should not be connected to the appliance until step 12 Connect the Gas Line Page 38 NOTE All fireplaces are factory equi...

Page 20: ...1 Remove the eight 8 screws holding the top vent cover plate and gasket Step 2 Remove the round flue cover from the top venting outlet Step 3 Remove insulation from inside flue pipe Step 4 Make sure insulation disc is still in the round cover Remove the flue plug from the top flue Step 5 Bend tabs out on round flue cover Secure the round flue cover provided to the wrapper over the rear venting out...

Page 21: ... Figure 10 Nailing flanges are provided for flush framing 1 2 and 5 8 framing depths 2 Secure the fireplace to the side framing members using the unit s nailing flanges one top and bottom on each side of the fireplace front Figure 10 Use 8d nails or the equivalent Figure 10 Nailing Flanges Side framing Unit nailing flange no clearance to combustible framing is required Vent System Preparation 9 Se...

Page 22: ...PLACE COLLAR Inner Fireplace Collar Appliance Rear Vent Outlet U Shaped Vent Restrictor Intake Air Baffle Base Vent Restrictor Base Vent Restrictor Wing With break away raised Inner Fireplace Collar Appliance Rear Vent Outlet U Shaped Vent Restrictor Intake Air Baffle Figure 14 Vent restrictor assembly U Shaped Vent Restrictor Inner Fireplace Collar Appliance Top Vent Outlet U SHAPED VENT RESTRICT...

Page 23: ... desired a 6 x 1 2 screw can be used at the joint but is not required as the pipe will securely lock when twisted Figure 16 Where required a telescopic vent section SV4 5LA may be used to provide the installer with an option to install in tight and confined spaces or where the vent run made up of fixed length pieces develops a joint in a undesirable location or will not build up to the required le...

Page 24: ... 3 465 38 75 0 0 0 0 10 10 69 5 75 0 0 0 2 0 2 475 5 39 625 0 1 0 0 10 11 73 5 6 125 1 0 0 2 0 3 480 40 1 1 0 0 10 12 79 5 6 625 0 1 0 2 0 3 492 41 1 0 1 0 10 12 81 6 75 0 0 0 1 1 2 499 5 41 625 0 0 0 1 10 11 91 5 7 625 0 0 2 0 1 3 504 42 1 0 0 1 10 12 93 7 75 0 0 0 0 2 2 511 5 42 625 0 0 0 0 11 11 97 5 8 125 1 0 0 0 2 3 520 5 43 375 0 2 0 1 11 14 103 5 8 625 0 0 0 3 0 3 531 44 25 0 2 2 0 11 15 10...

Page 25: ... walls is specified in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your local codes for specific requirements A general guide to follow is the gas vent rule Table 6 The following figures and their associated vertical vent tables illustrate the various configurations that are possible for use with these fireplaces Secure Vent pipe is sho...

Page 26: ...firestop spacer If there is living space above the ceiling level the firestop spacer must be installed on the bottom side of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side of the joist Route the vent sections through the framed opening and secure the firestop spacer with 8d nails or other appropriate fasteners at each corner Remember to mainta...

Page 27: ...s at top and sides only and trim where necessary Seal the top and both sides of the flashing with waterproof caulking 12 Install the storm collar Install the storm collar supplied with the flashing over the vent flashing joint Figure 22 Loosen the storm collar screw Slide collar down until it meets the top of the flashing Tighten the adjusting screw Apply non combustible caulking or mastic around ...

Page 28: ...ARNING Do NOT join separate sections of concentric flexible vent pipe Figure 24 Top Vent Straight Table 16 Rear Vent One 90 Elbow Ceiling firestop spacer SV4 5VF When using Secure Flex use ceiling firestop spacer SF4 5VF 60 ft 18 3 m maximum Ceiling firestop spacer SV4 5VF When using Secure Flex use ceiling firestop spacer SF4 5VF H V H Maximum V Minimum feet meters feet meters 2 0 610 1 0 305 4 1...

Page 29: ...any vent run with more than 6 ft of vertical rise See Page 22 for more information If 20 ft of H horizontal vent run is needed then 4 ft straight section minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 ft of V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run of 20 ft NOTE The vent system may have a maximum of three 3 90 el...

Page 30: ...nimum clearances for combustibles Page 15 16 2 Frame the exterior wall opening Locate the center of the vent outlet on the exterior wall Table 10 Cut and or frame an opening 10 1 2 x 12 1 8 267 x 308 mm inside dimensions about this center 3 Frame the ceiling opening If the vertical route is to penetrate a ceiling use plumb line to locate the center above the fireplace Cut and or frame an opening 1...

Page 31: ...ptor SV4 5RCH provided with the termination to the vent section or telescoping vent section elbow or fireplace collar Figure 26 13 Install the firestop spacer at the exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the opening at the exterior side of the framing long side up with the 3 spacer clearance at the top Figure 26 and nai...

Page 32: ...ent stucco or masonry wall surface Venting Connection and Exterior Wall Recessing of the Horizontal Square Termination SV4 5HT 2 Adaptor SV4 5RCH For thicknesses greater than 9 1 4 235 mm see Table 21 SV4 5HT 2 Square Termination Maximum Wall Thickness 9 1 4 235 mm Exterior Surface of Siding Exterior Surface of Framing 6 to 9 1 4 152 to 235 mm 1 1 4 Maximum Recess of the Square Termination into Ex...

Page 33: ...spacer must be used any time vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent SF4 5HF Secure Flex firestop spacer must be used any time vent pipe passes through a combustible wall WARNING Do not join separate sections of concentric flexible vent together Table 21 Rear Vent No Elbows Compact termination SV4 5HTKCT shown See Table 20 as an aid in venting component selectio...

Page 34: ... 5 1 524 2 0 610 1 0 305 10 3 048 4 1 219 2 0 610 15 4 572 6 1 829 3 0 914 25 7 62 10 3 048 5 1 524 V H H1 60 ft 18 288 m maximum H 8 ft 2 438 m maximum H H1 25 ft 7 62 m maximum Install the U shaped vent restrictor in any vent run with more than 4 ft of vertical rise See Page 22 for more information See Table 20 as an aid in venting component selection for a particular range of exterior wall thic...

Page 35: ...V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run of 20 ft 6 096 m Table 27 Top Vent Three 90 Elbows H Maximum V Minimum When using Secure Flex use Ceiling Firestop Spacer SF4 5VF When using Secure Flex use Wall Firestop Spacer SF4 5HF Ceiling Firestop Spacer SV4 5VF Wall Firestop Spacer SV4 5HF V H V1 Wall Firestop Spacer SV4 5HF 1 H Wall firestop spacer SV4 5HF W...

Page 36: ...ANT P N 10K81 to the outside surface of both collars of the adaptor fill the grooves of the outer collar to be covered by the flexible pipe and slide the flexible vent over the inner and outer adaptor collars NOTE Outer vent pipe is pulled away to show inner vent pipe details 1 3 4 44 mm flexible vent and adaptor outer collar overlap Adaptor SV4 5RF Attach adaptor to vent collar or Secure Vent sec...

Page 37: ... separately and attached to bulk lengths of Secure Flex flexible vent cut to size at the job site Attach the flexible vent to the Secure Flex terminations as it was attached to the adaptor Figure 28 NOTE Attach Secure Flex vent to Secure Flex terminations only Do NOT substitute Secure Vent terminations or Secure Vent adaptor for Secure Flex components Secure Flex termination and adaptor collars ar...

Page 38: ...let cover plate from the side of the unit by removing the plate s securing screws Table 12 3 If unit is not supplied with a strain relief remove the cover plate knockout Then feed the power supply wire through the knockout opening and into the unit junction box 4 Connect the black power supply wire to the lower outlet s black and red pigtail lead Figure 31 Connect the white power supply wire to th...

Page 39: ...ply line The orientation of the shutoff valve should face the front Figure 32 illustrates two methods for connecting the gas supply A sediment trap is recommended to prevent moisture and debris in the gas line from damaging the valve Test Factory and Field Connections for Gas Leaks WARNING Never use an open flame to check for leaks Turn on gas supply and test for gas leaks using a gas leak test so...

Page 40: ...es It accepts commands via radio frequency from the transmitter and does not require line of sight operation The wall switch can be set to one of three 3 positions ON Manual Override REMOTE Remote Control OFF Initializing the remote control system for the first time 1 Install the four 4 AA batteries into the wall switch battery bay behind the switch plate NOTE Check the polarity of the batteries a...

Page 41: ...N in the high position A single beep will confirm reception of the command Room thermostat transmitter operation The remote control can operate as a room thermostat 1 Press the THERMOSTAT key 2 The LCD display on the transmitter will change to show that the room temperature is ON and the set temperature will be displayed 3 To adjust the set temperature press the UP or DOWN ARROW keys until the des...

Page 42: ...t a the beep when the ON OFF key is pressed Initializing the remote control system for the first time 15 Optional Install the Firebox Liners 1 See Page 54 for instructions on Traditional Only Installing the Firebox Liners 16 Traditional Fireplaces Install the Logs Volcanic Stone and Glowing Embers 1 See Page 55 for instructions on Installing the logs volcanic stone and glowing embers 17 Contempora...

Page 43: ...ty The following chart is provided to help achieve the correct air shutter adjustment for your installation Table 28 Air Shutter Adjustment Guidelines Figure 37 Air Shutter Adjustment Rod Amount of Primary Air Flame Color Air Shutter Adjustment Air Shutter Adjustment Rod Down Fully Open Position Burner Tube Adjustment Rod Up Fully Closed Position Adjustment Set Screw If air shutter is closed too f...

Page 44: ...E All models must have a barrier installed prior to operation 1 Open the control compartment door Page 53 2 Hold the barrier in front of the glass door and slide it up into the slots above the glass door and under the hood 3 Slide the barrier bottom down into the slots below the glass door securing it in place 22 Install the Finishing Materials 1 Complete finished interior wall NOTE To install the...

Page 45: ...ussière et les traces degraisseoud huile Collezl étiquettesurleboîtier de la télécommande Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 3 Si vous ne trouvez pas les étiquettes veuillez appelerInnovativeHearthProductsouvotredistribu teurInnovativeHearthProductslocalpourrecevoir gratuitement des étiquettes ...

Page 46: ...750109M 77L71 SV4 5L12 12 305 mm 77L72 SV4 5L24 24 610 mm 17M53 SV4 5HGS 12 Termination Guard Horizontal Square 12 pack see 750109M 77L73 SV4 5L36 36 914 mm 87L02 SV4 5HGS Termination Guard for Horizontal Square Termination Deluxe 1 pack see 750055M 77L74 SV4 5L48 48 1219 mm 77L75 SV4 5LA Telescopic Length Slip Section 2 7 1 2 rigid 77L76 SV4 5E45 45 Elbow H5820 SV4 5HTSK Termination Shroud Guard ...

Page 47: ...50052M H2248 SF4 5HF 10 Firestop Spacer Horizontal flex 3 1 1 spacing 10 Pack H2249 SF4 5VF 10 Firestop Spacer Vertical flex 1 1 1 spacing 10 Pack H1969 SF4 5HT 2 Horizontal Square Termination for flex without flex H7748 H7748 36 Flex Connector Kit 36 of flex with two adaptors for mating two rigid sections of vent together 77L87 SFKIT12S Square Term for flex with 12 305 mm compressed flex 77L88 SF...

Page 48: ...ion de monoxyde de carbone pouvant causer des dommages matériels des blessures ou la mort Le tecnicien agréé est responsable de l installation de cette trousse L installation n est pas adéquate ni complète tant que le bon fonctionnement de l appareil converti n a pas été vérifié selon les instructions du fabricant fournies avec la trousse Le fournisseur de service qualifié ayant réalisé l installa...

Page 49: ...gnition System Fireplaces 7 Refer to the instructions provided with the SIT Regulator Conversion Kit and Figure 40 Using a Torx T20 driver with 1 4 shank or slotted screwdriver remove and discard the pressure regulator mounting screws two screws for electronic models three screws for millivolt models pressure regulator tower the diaphragm assembly if applicable and the spring Discard all removed c...

Page 50: ...ner assembly into its position and secure the trapezoidal plate with the two screws previously removed 14 Reinstall the baffle with the two baffle securing screws 15 Reassemble the remaining components 16 Turn on gas supply and test for gas leaks Page 39 17 Relight the main burner The lighting instructions can be found on the lighting label in the control compartment or Page 64 Verify proper burne...

Page 51: ...fected by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or other combustible materials within 36 of the front of viewing area s NOTE Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clo...

Page 52: ...dence du propriétaire 2 Repérezlatélécommandeetnettoyez lasoigneuse ment pour éliminer la poussière et les traces de graisseoud huile Collezl étiquettesurleboîtierde la télécommande Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire 3 Sivousnetrouvezpaslesétiquettes veuillezappeler Innovative Hearth Products ou votre distribu teur Innovative Hearth Produc...

Page 53: ...ontrol Compartment Door 1 Remove the bottom left screw Figure 43 inside the control compartment securing the control compartment door Retain the screw for later reinstallation 2 Position the left side door tab Figure 44 out of the tab groove and align it with the vertical slot Figure 43 Figure 43 Control compartment door slots Figure 44 Control compartment door tabs Vertical slot Screw hole Tab pi...

Page 54: ...artup i e the pilot and burner ignite but the burner extinguishes and reignites several times until the flue reaches the temperature for proper drafting To save energy switch to intermittent mode For a standing pilot that will help prevent glass door condensation and cycle startup switch to continuous mode NOTE Continuous mode is indicated by a pilot that comes ON and remains lit when the fireplac...

Page 55: ...mproper combustion could occur This could result in the excessive production of soot and or the colorless odorless toxic gas carbon monoxide CO NOTE If applicable install the firebox liner before placing the stone Logs can be installed after the volcanic stone Installing the volcanic stone and glowing embers 1 If necessary remove the glass door Pages 58 59 2 Spread the decorative volcanic stone in...

Page 56: ...1 If necessary remove the glass door Pages 58 59 Locate Log Placement Brackets Figure 48 2 Bend up the log placement brackets Figure 48 Place embers and other media see Pages 54 57 Figure 48 Locating the log placement brackets Figure 49 Placing log 1 and 2 Left and Right Log Placement Brackets 2 3 Align the notches in the rear left log 1 with the left rear brackets Figure 48 4 Position the rear le...

Page 57: ...Log 4 Left Front Log Catalog number for the entire set F2195 for Aurora 40 Series F2197 for Aurora 45 Series 1 If necessary remove the glass door Pages 58 59 Locate and bend up the log placement brackets Figure 52 Figure 52 Locating the log placement brackets Figure 53 Placing logs 1 and 2a Left and Right Rear Log Bracket Left Front Bracket Right Front Bracket 2a 2 Position rear left log 1 on the ...

Page 58: ...the risk of burns from the hot viewing glass is provided with this appliance and shall be installed WARNING Une barrière conçue pour réduire le risque de brûlure par le hublot chaude est fournie avec l appareil et doit être installé WARNING Do not operate appliance with the glass front removed cracked or broken AVERTISSEMENT Ne pas utiliser l appareil si le panneau frontal en verre n est pas en pl...

Page 59: ... gasket seats evenly as the door draws shut Securely fasten the two 2 latches beneath the firebox floor to the door V flange 4 Install the barrier 5 Close the control compartment door Removing the glass door 1 Open the control compartment door Page 53 NOTE If necessary remove the door and place it in a safe location for later reinstallation 2 Remove the barrier Place the barrier in a safe location...

Page 60: ... venting system components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically during the burn season inspect the horizontal termination for debris such as bird nests leaves paper or branches Remove any items from the surfaces of the termination prior to use Also be aware of...

Page 61: ... paint brush Reinstalling the embers and logs Carefully follow the placement instructions Page 55 All logs should fit onto the corresponding pins and or log stoppers This will ensure proper flame and safe combustion NOTE Improper positioning of logs can create carbon build up and will alter the performance of the fireplace Replacing the logs If the logs become damaged and need replacement use only...

Page 62: ...onents Appliance Inspection Qualified Service Technician Perform the appropriate appliance inspection procedure detailed in this manual Replacing Rockwool Ember Materials Homeowner Qualified Services Technician Remove old ember materials and vacuum the rockwool placement area Place new rockwool as described in this document Table 37 Maintenance Performed Periodically After the Burning Season Maint...

Page 63: ...F2224 BLKBP 35 Black Reflective 35 Models F2225 BLKBP 40 Black Reflective 40 Models F2226 BLKBP 45 Black Reflective 45 Models Brickaded Firebox Liner Kits Table 41 Brickaded Firebox Liner Kits Catalog Model Description Used on F1827 MBLK35B Buff 35 Models F2188 BLK35OTR H Old Town Red Herringbone F1828 MBLK40B Buff 40 Models F2189 BLK40OTR H Old Town Red Herringbone F1889 MBLK45B Buff 45 Models F2...

Page 64: ...A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use an...

Page 65: ...vante 8 Mettez l appareil sous tension 9 Placez l interrupteur du récepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour sélectionner ON 11 Ajustez le thermostat sur la télécommande à l ajustement désiré 12 Si l appareil ne se met pas en marche suivez les instructions intitulées Comment couper l admission de gaz de l appareil et appelez un technicien qualifié ou le fournisseur de gaz 1 ...

Page 66: ... Air in the gas line Purge gas line of air call a service technician if required e Unit is not receiving power Replace unit battery backup 3 The main Burner comes on but then goes out a Gas is not reaching the fireplace Check the gas supply and gas shutoff valves b Loose wires to the valve or ignition module Check control compartment for any obviously loose wiring call a service technician if nece...

Page 67: ... Vent Restrictor Wing H8988 1 H8988 1 H8988 1 Door Latch Assembly H6135 2 H6135 2 H6135 2 Assembly Harness Control H8601 1 H8601 1 H8601 1 2 Vent Stopper Plug J7356 1 J7356 1 J7356 1 3 Burner Assembly J7353 1 J7354 1 J7354 1 4 Square Grate H7719 1 H7720 1 H7720 1 Manning Glass Gasket F2116 1 F2116 1 F2116 1 Porcelain Panel Right J7391 1 J7394 1 J7394 1 Porcelain Panel Left J7392 1 J7395 1 J7395 1 ...

Page 68: ...ont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées Table 45 Homeowner Replacement Parts Description 35 Models 40 Models 45 Models Catalog Number Qty Catalog Number Qty Catalog Number Qty 5 Hood F1837 1 F1838 1 F1901 1 6 Barrier F1839 1 F1840 1 F1903 1 7 Ceramic Door J7388 1 J7389 1 J7390 1 8 Control Compart...

Page 69: ...ge to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate fireplace system draft caused by air condit...

Page 70: ...nsult your local distributor for fireplace code information Printed in U S A 2015 Innovative Hearth Products P N 900475 00 Rev NC 08 2015 1508 Elm Hill Pike Suite 108 Nashville TN 37210 P900475 00 Contact an IHP dealer to obtain any of these parts Please contact IHP for the phone number of your nearest IHP dealer ComfortFlame us com Record the following important information about your fireplace F...

Reviews: