Comfort Bilt HP22 Operator'S Manual Download Page 5

Operator’s Manual                                                                                                             

HP22 Pellet Stove

 

~ 5 ~

 

 

 

 

CAUTION 

ALL APPLICABLE BUILDING CODES FOR YOUR 

LO

CATION  MUST  BE  FOLLOWED.  IN  AREAS  WHERE 

BUILDING  CODES  REQUIRE  ADDITIONAL  STEPS  TO  THE 
INSTALLATION OF THIS PRODUCT NOT INCLUDED IN THIS 
MANUAL, THE BUILDING CODES WILL TAKE PRECEDENT 
AND  MUST  BE  FOLLOWED.  CONTACT  YOUR  LOCAL 
BUILDING  INSPECTOR  TO  OBTAIN  ANY  NECESSARY 
PERMITS  OR  INSPECTION  GUIDELINES  BEFORE 
INSTALLING THE PRODUCT. 

  Contact  local building  or fire officials about 

restric

tions and installation inspection requirements in 

your area.

 

• 

Contact your local authority    (such as municipal building 

department, fire department, fire prevention bureau, etc.) to 
determine the need for a permit. 

•  This pellet stove is designed to 

burn pellet fuel 

only. 

•  A working smoke  detector  is required and 
must be installed in the same room as the stove. 

•  This stove is  not  intended for  use  in 

commercial 

applications. 

  Door and ash  pan  must be  closed  and 

latched   during 

  operation. 

•  Notify your insurance company of pellet stove

  instal

lation. 

  This installation must conform with local 

codes. In 

  the absence of local codes you must comply 

with EN 14785. 

•  The structural   

integrity  of  the 

manufactured home floor, wall, and ceiling/roof 
must be maintained.   

•  Keep combustible  materials (such 

as 

grass,  leaves, 

  etc.) at least three feet away from the 

flue outlet on the outside of the building. 

•  This stove should  not be used as the only 
source   of heat in the house. Power outages and 
periodic maintenance will result in a total loss of 
heat.

   

•  Do not leave hopper door open while unattended.

 

 

 

  CAUTION 

INSTALLATION  AND  REPAIR  OF  THIS  PELLET 

STOVE 

SHOULD  BE  DONE  BY  A  QUALIFIED  SERVICE 

PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE 
USE  AND  AT  LEAST  ONCE  A  YEAR  BY  A  QUALIFIED 
SERVICE PERSON. IT IS IMPERATIVE THAT THE CONTROL 
COM- PARTMENTS, FIRE BOX, AND THE CIRCULATING AIR 
PASSAGEWAYS OF THE STOVE BE KEPT CLEAN.   

THE OPERATION OF  EXHAUST FANS SUCH AS 

BATH-

ROOM FANS, ATTIC FANS, ETC. MIGHT STARVE THE 

PELLET  STOVE  OF  COMBUSTIBLE  AIR  CREATING  A 
NEGATIVE PRESSURE IN THE ROOM. PROVIDE ADE- QUATE 
VENTILATION OF THE ROOM ACCOMPANYING   

THE PELLET STOVE. IF NOT, THE PRESSURE 
SWITCH   
MAY SHUT OFF OPERATION OF THE PELLET 
STOVE. 

THE  MOVING  PARTS  OF  THIS  STOVE  ARE 

PROPELLED  BY 

HIGH  TORQUE  ELECTRIC  MOTORS. 

THESE  PARTS  CAN  CAUSE  SEVERE  DAMAGE  TO  BODY 
PARTS  THAT  GET  NEAR  THEM.  KEEP  ALL  BODY  PARTS 
AWAY  FROM  AU-  GER  AND  FANS  WHILE  THE  STOVE  IS 
PLUGGED INTO AN   

ELECTRICAL OUTLET. THESE MOVING PARTS 
MAY BE- 
GIN TO MOVE AT ANY TIME THE STOVE IS 
PLUGGED IN.   

THE  VENT  SURFACES  CAN  GET  HOT  ENOUGH 

TO  CAUSE 

BURNS  IF  TOUCHED.  NONCOMBUSTIBLE 

SHIELDING OR GUARDS MAY BE REQUIRED. 

INSTALL VENT AT CLEARANCES SPECIFIED BY 

THE 

VENT MANUFACTURER. 

ALL VENTING JOINTS, WHETHER VERTICAL OR 

HORI-

 ZONTAL, SHOULD BE MADE GAS-TIGHT WITH REC- 

OMMENDED  SEALANTS  SPECIFIED  BY  VENT  MANU- 
FACTURER. 

ACCORDING  TO  HUD  (HOUSING  &  URBAN 

DEVEL

OPMENT) REQUIREMENTS, WHEN INSTALLED IN A 

MOBILE  HOME,  THIS  STOVE  MUST  BE  GROUNDED 
DIRECTLY TO THE STEEL CHASSIS OF THE MOBILE   

HOME AND BOLTED TO THE FLOOR. DIRECT 
AIR ACCESS MUST BE PROVIDED, USE A 
FRESH AIR KIT. 
FOR USE IN THE UNITED STATES AND CANADA.   
AP- 
PROVED FOR INSTALLATION IN MOBILE 
HOMES. 

PRODUCER  OF  THIS  APPLI

ANCE,  RESERVES  THE 

RIGHT TO ALTER ITS PRODUCTS, SPECIFICATIONS AND/OR 
PRICE WITHOUT NOTICE. 

 

Summary of Contents for HP22

Page 1: ...OR EVEN DEATH CAUTION DO NOT DISCARD IMPORTANT OPERATING AND AINTENANCE INSTRUCTIONS INCLUDED SAVE THESE INSTRUCTIONS AND LEAVE THIS MANUAL WITH ANY PARTY RESPONSIBLE FOR USE AND OPERATION I M P O R T...

Page 2: ...NG AND MAINTENANCE IN STRUCTIONS INCLUDED READ UNDERSTAND AND FOLLOW THESE IN STRUCTIONS FOR SAFE INSTALLATION AND OP ERATION LEAVE THIS MANUAL WITH PARTY RESPONSIBLE FOR USE AND OPERATION CAUTION CHE...

Page 3: ...uses this stove must read the instructions and be familiar with the controls This symbol points out important safety instructions which if not followed could endanger your personal safety Read and fo...

Page 4: ...arranty DO NOT route power cord in high traffic areas A power surge protector plugged into a grounded 230 volt power source is required DO NOT install a flue damper in the exhaust venting system of th...

Page 5: ...en while unattended CAUTION INSTALLATION AND REPAIR OF THIS PELLET STOVE SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ONCE A YEAR BY A QUALIFI...

Page 6: ...ion Clearances 12 13 Outside Air Connection 14 Mobile Home 14 Venting Installation Examples 15 20 BECOMING FAMILIAR WITH YOU CONTROLLER 21 22 Controller Buttons 21 Screen Display 22 PRE OPERATION 23 O...

Page 7: ...nce of the unit and will void the warranty The Pellet Fuel Institute PFI has established standards for wood pellet manufacturers Only use pellets that meet or exceed PFI standards for premium fuels CL...

Page 8: ...sture content Consult your dealer for best results 2 Based on post 1982home construction requiring 35 BTU Hr per Sq Ft GLASS SPECIFICATIONS This stove is equipped with ceramic glass Replace glass only...

Page 9: ...learance is 2 from the back of the stove to the wall SEE FIGURE 2 The minimum floor protector material is 24 GA sheet metal Figures 1 Figures 2 Figures 1 and 2 Pellet stove floor pad clearances WARNIN...

Page 10: ...ation through the wall vents Figure 5 Straight installation interior vertical vents Figure 6 Corner installation interior vertical vents NOTE When interior vent is installed vertically the clearance t...

Page 11: ...nuisance or hazard from exposure to high temperatures The installation must include a clean out tee to enable collection of fly ash andto permit periodic cleaning of the exhaust system Total length of...

Page 12: ...must not be located where it will become plugged by snow or other material A A Minimum 4 clearance below or beside any door or window that opens This clearance may be reduced to 18 if using out side...

Page 13: ...performance it is recommended that you keep the vent as short as possible especially in regards to the horizontal run The vent must have a support bracket every 5 of pellet vent when on the exterior o...

Page 14: ...INSTALL IN A SLEEPING ROOM CAUTION THE OPERATION OF EXHAUST FANS SUCH AS BATHROOM FANS ATTIC FANS ETC MIGHT STARVE THE PELLET STOVE OF COMBUSTIBLE AIR CREATING A NEGATIVE PRESSURE IN THE ROOM PROVIDE...

Page 15: ...Operator s Manual HP22 Pellet Stove 15...

Page 16: ...Operator s Manual HP22 Pellet Stove 16...

Page 17: ...Operator s Manual HP22 Pellet Stove 17...

Page 18: ...Operator s Manual HP22 Pellet Stove 18...

Page 19: ...Operator s Manual HP22 Pellet Stove 19...

Page 20: ...Operator s Manual HP22 Pellet Stove 20...

Page 21: ...n weekly mode after raising the Call To temperature will maintain that temperature until the button is pressed again or the stove is shut down 8 Scroll Up Button Allows you to scroll up to choose item...

Page 22: ...g room 6 Additional Control Mode 7 Ignitor Indicator Indicates ignition cycle burning cycle is currently happening 8 Combustion Blower Indicator Indicates combustion blower is running 9 Auger Indicato...

Page 23: ...ore actually starting your Stove you will need to determine in which mode you would like to run the stove This stove can operate in three modes 1 Manual Under thismode you can personally adjust and se...

Page 24: ...room at the set temperature To increase or decrease the call to temperature use the SCROLL UP or SCROLL DOWN button The current room temperature will be displayed in the temperature display box on the...

Page 25: ...Next Pressing Figure 23 ENTER again will take you to the following day Proceed with setting a schedule for the rest of the week using the preceding instructions NOTE Along with the Next option on the...

Page 26: ...t without blowing cold air Increasing the blower voltage causes the convection motor to run faster extracting more heat from the unit NOTE If having issues with the stove overtemping in any setting in...

Page 27: ...t will also assist in burning lower quality fuels that may otherwise cause unwanted buildup NOTE Be sure to visually watch the burn rate if the combustion voltage is decreased as to not cause pot over...

Page 28: ...r stove to see if they are properly working By using the ENTER button you can highlight Fire Exhaust Blower or Feeder When one of these options is highlighted you can use the SCROLL UP or SCROLL DOWN...

Page 29: ...ry or damp rag If this does not clean the glass use any non abrasive cleaner Using ceramic stove top cleaner can be helpful in removing soot from the glass Inspect gaskets around the door periodically...

Page 30: ...will effect the quality of the fire Make sureto clean any screens in the venting regularly A plugged screen will shut of combustion air and cause the fire to die or burn poorly DAILY MAINTENANCE The s...

Page 31: ...and vacuumed thoroughly SEE FIGURE 36 This may require a hose adapter to reach inside the chamber This should be done monthly or with every 2 3 tons of fuel burned IMPORTANT NOTE A HOLE SHOULD BE CUT...

Page 32: ...NOT OPERATE UNIT WITH PANELS REMOVED OR OPEN HOT PARTS DO NOT OPERATE THE UNIT WITH PANEL OPEN RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT IN THE EVENT OF COMPONENT FAILURE REPLACE...

Page 33: ...door or ash pan not sealed No negative pressure in fire chamber Piping or stove may be plugged with ash The pressure sensor shuts off the feed auger when there is no negative pressure in fire chamber...

Page 34: ...y PROBLEM CAUSE SOLUTION Fire burns lazy and smoky Stove is dirty Poor quality fuel Clean fire pot Clean ash pan Clean exhaust vent system Clean stove through cover plate clean out hole Increase exhau...

Reviews: