PROBLEM
CAUSE
SOLUTION
Fuel not feeding, no hopper lid signal
on control
Hopper lid is open
Hopper lid switch not functioning correctly
Close hopper door. Enter the diagnostic area on the
controller; circle next to “limit” should be highlighted
when the hopper lid is closed. The circle will be unshaded
if the hopper lid is opened.
Check hopper door seal.
Replace hopper safety switch if not operating properly.
PROBLEM
CAUSE
SOLUTION
Fire burns lazy and smoky
Stove is dirty
Poor quality fuel
Clean fire pot.
Clean ash pan.
Clean exhaust vent system.
Clean stove through cover plate clean-out hole.
Increase exhaust motor Voltage.
PROBLEM
CAUSE
SOLUTION
Feeds fuel will not light all; control indicators are on
Igniter tube or burn pot plugged with ash
Faulty igniter
Clean fire pot, clean igniter tube. Enter the diagnostic
area in the controller and test the ignitor by highlighting
“fire”. You should feel heat coming from the igniter
holder within two minutes.
Replace if necessary