When the air filter is to be 

removed, do not touch the metal 

parts of the unit.

M

ay cause an injury.

Do not clean unit when power is on 

as it may

 cause fire, electric 

shock,

 or 

injury.

Operation 

with 

windows 

open 

may cause wetting of indoor and 

soaking of household furniture.

When the unit is to be cleaned, 

switch off, 

and unplug

.

Use caution when unpacking and 

installing. Sharp edges could cause injury.

Do not clean the air conditioner 

with water.

Water may enter the unit and 

degrade the insulation. It may 

cause an electric shock.

This could injure the pet or plant.

M

ay cause electric shock and 

damage.

Do not put a pet or house plant 

where it will be exposed to direct 

air flow.

Ventilate the room well when

used together with a stove, etc.

An oxygen shortage may occur.

Do not use this air conditioner to 

preserve precision devices, food,

 

pets, plants

 or

 art objects.

 

It may 

cause deterioration of quality, etc. 

M

ay cause failure of product or

fire.

Do not use for 

other than 

human comfort

.

If water enters the unit, turn the unit off at the power 

outlet and switch off the circuit breaker. Isolate 

supply by taking the power-plug out and contact a 

qualified service technician.

!

!

!

!

It may cause

 appliance

 failure 

o

r accident.

Finish

 may be 

damaged.

If bracket is damaged, there is

 

concern of damage

 or injury

 due 

to falling of unit.

There is danger of fire or electric 

shock.

Operation without filters may

 

cause 

failure.

It contains contaminants and 

could make you sick.

Stop operation and close 

window

s

 in storm or hurricane.

!

Do not use strong detergent

s,

  

wax or thinner

;

 use a soft cloth

 

only

.

Ensure that the 

outdoor support 

bracket 

is not damaged due to prolonged 

exposure.

Hold the plug by the head of the 

power plug when taking it out.

!

Disconnect power

 when not 

using the

 

unit for a long time.

!

!

!

Clean filter once every

 

wo weeks.

!

Do not place heavy object

s

 on the 

power

 

cord and ensure that the cord is 

not compressed.

Do not drink water drained 

from air conditioner.

   This appliance is not intended for use by persons 

   (including children) with reduced physical ,sensory 

   or mental capabilities or lack of experience and 

   knowledge, 

unless t

 hey h

 ave

 

b een

 

gi ven

 

supervision

   or instruction concerning use of the appliance by 

   a person responsible for their safety. 

   Children should be supervised to ensure that they 

   do not play with the appliance. 

   If the supply cord is damaged, it must be replaced 

   by the manufacturer, its service agent or similarly 

   qualified persons in order to avoid a hazard.

CAUTION

2

CAUTION

Do not place obstacles around 

air-inlets or inside of air-outlet.

Th

is 

appliance sh

ould

 be installed in 

accordance

 

with national wiring regulations.

Do not operate your air conditioner in a wet

 

room

 

 

such as a bathroom or laundry room.

The appliance with electric heater shall have at

 

least 

3 ft.

 

space

 

to co 

mbustible

 

materials.

 

    

Contact

 an

 authori

z

ed service technician for    

repair or maintenance of this unit.

Contact 

an

 authori

z

ed installer for installation    

of this unit.

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for CB081A

Page 1: ... 1900 Wellworth Ave Jackson MI 49203 517 787 2100 www heatcontroller com OWNER S MANUAL Room Air Conditioner with R 410A BG 81M BG 101M BG 103M BG 121M BG 123M BG 143M BGE 103M BGE 123M BGE 143M www marsdelivers com Owner s Manual Owner s Manual Room Air Conditioner with R 410A CB081A CB101A CB103A CB121A CB123A CB143A CBE103A CBE123A CBE143A ...

Page 2: ... Ventilate room before operating air conditioner if there is a gas leak from another appliance May cause electric shock or fire due to excess heat generation May cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock May cause fire and electric shock It may cause fire May cause explosion fire and burns May cause electric shock or fire due to heat generatio...

Page 3: ...ern of damage or injury due to falling of unit There is danger of fire or electric shock Operation without filters may cause failure It contains contaminants and could make you sick Stop operation and close windows in storm or hurricane Do not use strong detergents wax or thinner use a soft cloth only Ensure that the outdoor support bracket is not damaged due to prolonged exposure Hold the plug by...

Page 4: ...le If the air conditioner is to be installed in a window you will probably want to clean both sides of the glass first If the window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner hasbeensecurelyandcorrectlyinstalledaccording to the installation instructions in this manual Save this manual for possible future use in ...

Page 5: ... remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified electrician When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils Save Carton and these Installation Instructions for future reference The carton is the best w...

Page 6: ...old Air Conditioner from wall sleeve and prepare wall sleeve as follows Clean interior do not disturb seals Wall sleeve must be securely fastened in wall before installing Air Conditioner Drive more nails or screws through sleeve into wall if needed Repair paint if needed 3 If not existing drill a 1 8 clearance hole for grounding screw through left side of wall sleeve in a clear area about 3 inche...

Page 7: ...ear grille it needs to be replaced by one that has been shipped with the unit in the accessory kit FOR INCREASED EFFICIENCY UTILIZE THE PROVIDED LOUVERED REAR PANEL Installation of new grille provided with unit 1 Remove the existing grille 2 Place the grille included with the new air conditioner towards the rear of the sleeve 3 Mark through the hole positions 4 Drill through the sleeves flanges wi...

Page 8: ...seal making sure the ground wire does not become tangled 11 Seal Frame the unit as described on page 17 12 If you have difficulty with mounting the grill to the sleeve follow the instructions for direct mounting on Page 16 1 2 1 2 1 2 2 4 4 4 4 3 8 3 8 1 Emerson 15 Deep 1 Remove existing rear grille as shown on Page 6 of this manual and replace with provided louvered rear panel Install as shown he...

Page 9: ... Cut 2 1 x3 8 x25 long seals to 14 long and attach it to the vertical sections of the rear grille as shown 8 Gently slide unit into sleeve 9 Before sliding all the way back remove 2nd screw from front on left side of unit 10 Remove the plastic washer from the screw 11 Screw and attach the other end of the ground wire to the unit as shown in picture Make sure that the toothed washer is against the ...

Page 10: ...etely to the rear to ensure a good seal making sure the ground wire does not become tangled 1 1 2 1 2 2 1 2 2 Cut Here 3 4 17 Tapered Spacer Block 1 Protection Paper Backing 12 1 2 2 1 2 1 2 1 2 5 4 4 4 4 3 8 3 8 4 The 2 1 2 section is placed in front of the rib on base with the tapered end facing the back of the sleeve Cut the remaining portion to 12 and placed behind the rib again sloping toward...

Page 11: ...1 Slide the unit completely to the rear to ensure a good seal making sure the ground wire does not become tangled 1 2 3 4 17 Tapered Spacer Block 1 Protection Paper Backing Cut Here 13 5 4 4 4 4 4 3 8 3 8 3 Install 13 section as shown with the tapered end from the back of the sleeve This helps induce a rear ward slope on the unit 4 Attach 1 1 x 3 8 x 25 long seal in the center at the top of the sl...

Page 12: ...picture Make sure that the toothed washer is against the cabinet 11 Slide the unit completely to the rear to ensure 1 2 5 4 4 4 4 4 3 8 3 8 5 Sears of Carrier 51S Series 18 5 8 Deep 1 Remove existing rear grille as shown on Page 6 of this manual and replace with provided louvered rear panel Install as shown here NOTE you may need to drill holes in flange of existing sleeve to match new rear grille...

Page 13: ...letely to the rear to ensure a good seal making sure the ground wire does not become tangled 12 Seal Frame the unit as described on page 17 3 4 17 Tapered Spacer Block 1 Protection Paper Backing Cut Here 13 5 4 4 4 4 4 3 8 3 8 3 Install 13 section to the floor of the sleeve as shown This helps induce a rearward slope on the unit 4 Attach 1 1 x 3 8 x 25 long seal in the center at the top of the sle...

Page 14: ...th first try dry fitting using the method described below 1 2 1 2 1 2 3 8 3 4 3 4 3 4 3 4 1 2 6 5 12 9 11 13 10 14 1 2 7 4 4 4 4 3 8 3 8 4 4 7 13 7 Whirlpool 23 Deep 1 Remove existing rear grille as shown on Page 6 of this manual and replace with provided louvered rear panel Install as shown here NOTE You may need to drill holes in flange of existing sleeve to match new rear grille 2 Place 2 1 x 1...

Page 15: ... toothed washer is against the cabinet 9 Slide the unit completely to the rear to ensure a good seal making sure the ground wire does 1 2 4 2 3 4 4 4 4 3 8 3 8 14 8 White Westinghouse Frigidaire Carrier 52F Series 16 17 1 2 Deep 1 Remove existing rear grille as shown on Page 6 of this manual and replace with provided louvered rear panel Install as shown here NOTE you may need to drill holes in fla...

Page 16: ...6 7 11 8 10 12 9 13 Remove existing rear grille as shown on Page 6 of this manual and replace with provided louvered rear panel Install as shown here NOTE You may need to drill holes in flange of existing sleeve to match new rear grille 5 6 4 4 4 4 3 8 3 8 4 4 15 9 White Westinghouse or Frigidaire 22 Deep 1 Remove existing rear grille as shown on Page 6 of this manual and replace with provided lou...

Page 17: ...e must be installed prior to inserting the unit into the sleeve 1 Attach the 2 seal pieces 1 X3 8 X14 as shown in Fig 1 2 Position the grille over the rear of the unit making sure that a The double set of screw holes are at the bottom b The fins of the grill are pointed away from the unit 3 Align the top of the grille with the top of the unit The overhang on each side is equal 4 If the unit has no...

Page 18: ... Conditioner with R 410A Owner s Manual 18 1 Install the 1 x1 x84 long stuffer seal between the wall sleeve and the unit A flat bladed screwdriver or putty knife is recommended 1 2 2 Assemble the trim frame by inserting top and bottom pieces into side pieces and snapping into place 3 Pull cord through trim frame then slide over unit until flush with wall INSTALLATION INSTRUCTIONS FINISHING INSTALL...

Page 19: ...ency compressors may have a high pitched chatter during the cooling cycle Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Droplets of water hitting condenser during normal operation may cause pinging or switching sounds Vibration Unit may vibrate and make noise because of poor wall or window construction ...

Page 20: ...r 2 C after an additional 30 minutes This new temperature will be maintained for 6 hours before it returns to the originally selected temperature This ends the Sleep modeand the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again Press Check filter button to initiate theis feature This featur...

Page 21: ...nd on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Temp Timer buttons at the same time for 3 seconds CAUTION Clean your air conditioner occasionally to ...

Page 22: ...ontrols may cause damage to the air conditioner Plug in air conditioner TROUBLESHOOTING TIPS Before calling for service review this list It may save you time and expense This list includes common occurrences that are not the result of defective workman ship or materials in this appliance Solution Air conditioner does not start Wall plug disconnected Push plug firmly into wall outlet House fuse blo...

Page 23: ...s windows registers etc Open cold air escapes Close doors windows registers Air conditioner turns on and off rapidly Noise when unit is cooling Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty air filter air restricted Clean air filter Air movement soun...

Page 24: ... on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective unit Labor to diagnose and replace the defective unit is not covered by this Limited Express Warranty If for any reason the replacement product is no longer available during the warranty period Coast Air shall have the right to allow a...