![Comfee CVP30W6AST User Manual Download Page 11](http://html1.mh-extra.com/html/comfee/cvp30w6ast/cvp30w6ast_user-manual_2640918011.webp)
LIGHTING
LIGHT REPLACEMENT
You cannot replaced the light bulbs, the entire light module has to be replaced.
When changing the light modules, the contacts are live.
Before changing the light module(s), unplug the appliance from the mains or switch off the
circuit breaker in the fuse box.
Replacing the light modules
Remove the grease filter .
Disconnect the terminal of LED light.
Press LED light on the back of the front plate, take the LED light out.
Replace the lamp(commercially available LED lamp (max.1.5w).
Press LED light on the front of front plate, install the LED light on the front plate.
Connect the terminal of LED light and light leads.
R
einstall the grease filter.
Reinstalling the LED light Module
Max Power Voltage
Picture
Lamp Cap ILCOS D code
Round/ Diameter:
1.5W
DC 12 V
——
DSR-1.5-S-70
11
2.76"