background image

IE-LOG-S0842-01 

 

  3 

Power current of connected contact: 3  A (contact closed) 
Voltage across open contact: maximum 3.6 V 
Cable parameters for connection of the binary input: 2 wires with common shielding 

(detailed information on cable – see page 9) 

Cable length for connection of the binary input: maximum 10 m 
Measurement interval measurement, alarm evaluation, memory MIN/MAX update and 

display refresh: 10 s 

Logging interval to memory: 10 s to 24 h (20 steps) 
Memory capacity:  

for non-cyclic logging mode 

10 834 records for each temperature channel 

for cyclic logging mode 

 

10 402 records for each temperature channel 

  Specified values are maximum possible and can be reached only if record since last 

memory erasing was not interrupted and no event on binary inputs was recorded. Each 
event record on the binary input decreases above capacity of one record.  

Communication with computer: via RS232 (serial port) by means of COM adapter or USB 

port by means of USB adapter; data transfer from logger via communication adapter is 
optical 

Real time clock: adjustable from computer, integrated calendar including leap years 
Error of internal RTC: < 200 ppm (i.e. 0.02 %, 17.28 s in 24 h) 
Power: Lithium battery 3.6 V size AA 
Battery life: 

typical (data download to PC is carried out about once a week): 5 years 
in continuous on-line mode with interval 1 minute: approximately 3 years 
in continuous on-line mode with interval 10 seconds: approximately 1 year 
Notice:  The above battery lives are valid for logger operation in temperature from -5 to 

+35°C. If often operated outside of the above temperature range battery life can be 
reduced to 75%. 

Protection: IP67 
Operational conditions: 
  Operational temperature range: -30 to +70 °C 
  Operational humidity range: 0 to 100 %RH 
   Specification of outer characteristics accordingly to Czech National Standard 33-2000-3: 

normal environment accordingly to appendix NM:  AE1, AN1, AR1, BE1 

   Operational position: negligible  

 Logger installation: by self adhesive Dual Lock, applied to clean, flat surface 
 Not allowed manipulation: it is not allowed to operate instrument with not connected 

temperature probes - if all probes are not connected, unconnected connectors should be 
protected by included connector cover. 

Limit condition: temperature -40 to +70 °C, humidity 0 to 100 %RH 
Storing condition: temperature -40 to +85 °C, humidity 0 to 100 %RH 
Dimensions: 93 x 64 x 29 mm 
Weight including battery: approximately 130 g 
Material of the case: ABS 
 
 

 

 

Summary of Contents for S0842

Page 1: ...LOGGER S0842 Three channel temperature logger with one binary input and LCD display Instruction Manual...

Page 2: ...tion is enabled or disabled for each channel individually Binary channel has no alarm mode Logging mode can be adjusted as non cyclic when logging stops after filling the memory In cyclic mode oldest...

Page 3: ...of internal RTC 200 ppm i e 0 02 17 28 s in 24 h Power Lithium battery 3 6 V size AA Battery life typical data download to PC is carried out about once a week 5 years in continuous on line mode with...

Page 4: ...eck or optionally set the logger real time clock select suitable logging interval it has no influence to binary inputs record select logging mode cyclic or non cyclic set for each channel type of temp...

Page 5: ...x memory could be stored Notice If logger operates as permanently connected to the computer using of magnet start stop is disabled To enable the logger control by magnet is suitable only in cases when...

Page 6: ...icates logger is ON If information on actual measured values is needed it is possible anytime to display reading display by means of the magnet only if communication adapter is not connected permanent...

Page 7: ...ndicated by INIT reading It can be displayed for about 12 s If battery voltage drop occurred since last internal clock setting below critical limit or battery disconnection for longer period than appr...

Page 8: ...ot possible to combine this function with function of switching logger OFF by magnet User software enables to select only one of them or none Plug magnet to guide slots from logger front side and wait...

Page 9: ...for temperature probe and binary contact It is possible to order as an optional accessory connector for connection of temperature probe Signal cable should be shielded round cross section of minimum d...

Reviews: